3,329 research outputs found
Impact of reionization on CMB polarization tests of slow-roll inflation
Estimates of inflationary parameters from the CMB B-mode polarization
spectrum on the largest scales depend on knowledge of the reionization history,
especially at low tensor-to-scalar ratio. Assuming an incorrect reionization
history in the analysis of such polarization data can strongly bias the
inflationary parameters. One consequence is that the single-field slow-roll
consistency relation between the tensor-to-scalar ratio and tensor tilt might
be excluded with high significance even if this relation holds in reality. We
explain the origin of the bias and present case studies with various tensor
amplitudes and noise characteristics. A more model-independent approach can
account for uncertainties about reionization, and we show that parametrizing
the reionization history by a set of its principal components with respect to
E-mode polarization removes the bias in inflationary parameter measurement with
little degradation in precision.Comment: 9 pages, 6 figures; submitted to Phys. Rev.
Knoop Hardness Of Composites Cured With Halogen And Led Lightcuring Units In Class I Restorations
Aim: To evaluate the effect of light-curing units (LCUs) on the microhardness of class I composite restorations at different depths. Methods: Two light emitting diodes (LED) (Freelight 2, Radii) and one halogen (Optilux 501) LCUs were evaluated. Thirty class I cavities prepared in human third molars were restored with a microhybrid (Charisma) and a microfilled (Renamel) resin composite. After seven days of water storage, the teeth were decoronated and the crowns were bisected mesiodistally and tested for microhardness under a 25 g load for 20 seconds. Fifteen indentations were performed at three depths for each half-crown. Results: Charisma presented significantly higher Knoop hardness number (KHN) values than Renamel. At the superficial depth, there were no statistically significant differences (p > 0.05) when Charisma was cured with both LED curing units. However, statistically significant difference (p < 0.05) was found when Charisma was light-cured with the halogen LCU. The lowest KHN value was obtained by Renamel light-cured with both LED LCUs, regardless of the composite. Nevertheless, when the microfilled composite was light-cured with the halogen LCU, hardness was significantly higher compared to those cured with LED units at all evaluated depths. Conclusions: The effectiveness of polymerization is related not only to the light-curing source, but also to the type of composite and the curing depth.8130-3
Simulations for single-dish intensity mapping experiments
HI intensity mapping is an emerging tool to probe dark energy. Observations
of the redshifted HI signal will be contaminated by instrumental noise,
atmospheric and Galactic foregrounds. The latter is expected to be four orders
of magnitude brighter than the HI emission we wish to detect. We present a
simulation of single-dish observations including an instrumental noise model
with 1/f and white noise, and sky emission with a diffuse Galactic foreground
and HI emission. We consider two foreground cleaning methods: spectral
parametric fitting and principal component analysis. For a smooth frequency
spectrum of the foreground and instrumental effects, we find that the
parametric fitting method provides residuals that are still contaminated by
foreground and 1/f noise, but the principal component analysis can remove this
contamination down to the thermal noise level. This method is robust for a
range of different models of foreground and noise, and so constitutes a
promising way to recover the HI signal from the data. However, it induces a
leakage of the cosmological signal into the subtracted foreground of around 5%.
The efficiency of the component separation methods depends heavily on the
smoothness of the frequency spectrum of the foreground and the 1/f noise. We
find that as, long as the spectral variations over the band are slow compared
to the channel width, the foreground cleaning method still works.Comment: 14 pages, 12 figures. Submitted to MNRA
Detection of Zak phases and topological invariants in a chiral quantum walk of twisted photons
Topological insulators are fascinating states of matter exhibiting protected
edge states and robust quantized features in their bulk. Here, we propose and
validate experimentally a method to detect topological properties in the bulk
of one-dimensional chiral systems. We first introduce the mean chiral
displacement, and we show that it rapidly approaches a multiple of the Zak
phase in the long time limit. Then we measure the Zak phase in a photonic
quantum walk, by direct observation of the mean chiral displacement in its
bulk. Next, we measure the Zak phase in an alternative, inequivalent timeframe,
and combine the two windings to characterize the full phase diagram of this
Floquet system. Finally, we prove the robustness of the measure by introducing
dynamical disorder in the system. This detection method is extremely general,
as it can be applied to all one-dimensional platforms simulating static or
Floquet chiral systems.Comment: 10 pages, 7 color figures (incl. appendices) Close to the published
versio
Coronary atherosclerosis as the main endpoint of non-invasive imaging in cardiology: A narrative review
The change of paradigm determined by the introduction of cardiac computed tomography (CCT) in the field of cardiovascular medicine has allowed new evidence to emerge. These evidences point towards a major role, probably the most important one in terms of prognostic impact, in the detection, characterization and quantification of atherosclerosis as the main driver and endpoint for the management of coronary artery disease (CAD). Extensive literature has been published in the last decade with large numbers and patients’ populations, investigating several aspects and correlations between atherosclerotic plaque features and risk factors; also, the relationship between plaque features, both with qualitative and quantitative approaches, and cardiovascular events has been investigated. More recent studies have also pointed out the relationship between the knowledge and classification of sub-clinical atherosclerosis and the induced modification of medical therapy (both aggressiveness and compliance) that is most likely able to increase the effect of anti-atherosclerotic drugs, hence significantly improving prognosis. Non-invasive assessment of CAD by means of CCT is becoming the primary tool for management and also the most important parameter for the comprehension of natural history of CAD and how the therapies we adopt are affecting plaque burden as a whole. In this review we will address the modern concepts of CAD driven understanding and management of cardiovascular disease
HI intensity mapping with FAST
We discuss the detectability of large-scale HI intensity fluctuations using
the FAST telescope. We present forecasts for the accuracy of measuring the
Baryonic Acoustic Oscillations and constraining the properties of dark energy.
The FAST -beam L-band receivers (-- GHz) can provide
constraints on the matter power spectrum and dark energy equation of state
parameters () that are comparable to the BINGO and CHIME
experiments. For one year of integration time we find that the optimal survey
area is . However, observing with larger frequency coverage
at higher redshift (-- GHz) improves the projected errorbars on the
HI power spectrum by more than confidence level. The combined
constraints from FAST, CHIME, BINGO and Planck CMB observations can provide
reliable, stringent constraints on the dark energy equation of state.Comment: 7 pages, 3 figures, submitted to "Frontiers in Radio Astronomy and
FAST Early Sciences Symposium 2015" conference proceedin
- …