633 research outputs found

    Anesthesia for endobronchial laser surgery: a modified technique

    Get PDF
    We describe a technique for endobronchial surgery with the neodynium:yttium-aluminum-garnet laser, in which an insufflation catheter with side holes placed into the contralateral mainstem bronchus is used for high-frequency positive pressure ventilation. Thirty-five patients (45 procedures) were treated during general anesthesia using a rigid bronchoscope in combination with a fiberoptic bronchoscope. Perioperatively, oxygen saturation (SaO2), mean arterial pressure, and heart rate were recorded. SaO2 during the recovery period was comparable to that during the intraoperative period but was significantly (P < 0.05) higher than that before the induction of anesthesia. There was a considerable (> or = 5%) increase in SaO2 at the end of the treatment in six patients, which indicates that the recanalization of the treated airway was successful. Our data support the assumption that, during endobronchial resection, selective ventilation of the nonaffected lung was adequate; in addition, subcarinal placement of the insufflation catheter with side holes was advantageous. We conclude that this technique contributes to the prevention of lung complications during endobronchial laser surgery. Implications: We describe a technique in which an insufflation catheter with side holes placed into the contralateral mainstem bronchus largely prevented inhalation of laser smoke and aspiration of blood and debris

    The additional value of an oblique image plane for MRI of the anterior and posterior distal tibiofibular syndesmosis

    Get PDF
    Objective: The optimal MRI scan planes of collateral ligaments of the ankle have been described extensively, with the exception of the syndesmotic ligaments. We assessed the optimal scan plane for depicting the distal tibiofibular syndesmosis. Materials and Methods: In order to determine the optimal oblique caudal-cranial and lateral-medial MRI scan plane, two fresh frozen cadaveric ankles were used. The angle of the scan plane that demonstrated the anterior and posterior distal tibiofibular ligament uninterrupted in their full length was determined. In a prospective study this oblique scan plane was then used in addition to the axial and coronal planes, for MRI scans of both ankles in 21 healthy volunteers. Two observers independently evaluated the anterior tibiofibular ligament (ATIFL) and posterior tibiofibular ligament (PTIFL) regarding the continuity of the individual fascicles, thickness and wavy contour of the ligaments in both the axial and the oblique plane. Kappa was calculated to determine the interobserver agreement. McNemar's test was used to statistically quantify the significance of the two scan planes. Results: In the axial plane the ATIFL was in 31% (13/42) partly and in 69% (29/42) completely discontinuous; in the oblique plane the ATIFL was continuous in 88% (37/42) and partly discontinuous in 12% (5/42). Compared with the axial plane, the oblique plane demonstrated significantly less discontinuity (p < 0.001), but not significantly less thickening (p = 1.00) or less wavy contour (p = 0.06) of the ATIFL. In the axial scan plane the PTIFL was continuous in 76% (32/42), partially discontinuous in 19% (8/42) and completely discontinuous in 5% (2/42); in the oblique plane the PTIFL was continuous in 100% (42/42). Compared with the axial plane, the oblique plane demonstrated significantly less discontinuity (p = 0.002), but not significantly less thickening (p = 1.00) or less wavy contour (p = 0.50) of the PTIFL. The interobserver agreement score and kappa (ΞΊ) regarding the continuity for the ATIFL in the axial and oblique planes was 91% (ΞΊ = 0.79) and 91% (ΞΊ = 0.55) respectively; for the PTIFL it was 86% (ΞΊ = 0.65) and 100% (ΞΊ = not defined). Conclusion: The ATIFL and PTIFL are routinuely scanned in the orthogonal planes. The advantage of MRI scanning in an oblique image plane of about 45 degrees permits a better evaluation of the ligaments compared with the axial plane, particularly a better interpretation of ligament continuity, thickening and wavy contour. This may lead to a reduction in false-positive results, especially regarding partial or complete ligament ruptures. This can be of considerable aid in therapeutic management

    Urinary Eosinophil Protein X in Children with Atopic Asthma

    Get PDF
    The aim of this study was to investigate the relationship between urinary eosinophil protein X (uEPX) and asthma symptoms, lung function, and other markers of eosinophilic airway inflammation in asthmatic school children. Methods. A cross-sectional study was performed in 180 steroid dependent atopic children with stable moderately severe asthma, who were stable on 200 or 500ΞΌg of fluticasone per day. uEPX was measured in a single sample of urine and was normalized for creatinine concentration (uEPX/c). Symptom scores were kept on a diary card. FEV1 and PD20 methacholine were measured. Sputum induction was performed in 49 and FENO levels measured in 24 children. Results. We found an inverse correlation between uEPX/c and FEV1 (r = βˆ’.20, P = .01) and a borderline significant correlation between uEPX/c and PD20 methacholine (r = βˆ’.15, P = .06). Symptom score, %eosinophils and ECP in induced sputum and FENO levels did not correlate with uEPX/c. Conclusion. uEPX/c levels did not correlate with established markers of asthma severity and eosinophilic airway inflammation in atopic asthmatic children

    Wireless sensor node mobility and its effect on transmission reliability

    Get PDF
    Abstract: Deploying a Wireless Sensor Network (WSN) poses certain challenges such as data reliability due to Electromagnetic Interference (EMI), multipath fading as well as faster energy depletion of nodes located near the base station creating communication holes in the network. Several energy efficient algorithms have been developed to improve the energy consumption of static nodes however the issue of battery depletion of nodes near the base station remains present. In this paper we attempt to model the relationship between the node mobility and the reliability of data transmission. Mobile nodes could move near static nodes experiencing high traffic in order to reduce the number of packets sent through the saturated nodes. This paper will investigate, using a real environment, the effect of speed and packet size on the reliability of the wireless link. This is a required prerequisite, prior to a detailed design of a Mobile relay node

    Prediction of 60 day case-fatality after aneurysmal subarachnoid haemorrhage: results from the International Subarachnoid Aneurysm Trial (ISAT)

    Get PDF
    Aneurysmal subarachnoid haemorrhage (aSAH) is a devastating event with substantial case-fatality. Our purpose was to examine which clinical and neuro-imaging characteristics, available on admission, predict 60 day case-fatality in aSAH and to evaluate performance of our prediction model. We performed a secondary analysis of patients enrolled in the International Subarachnoid Aneurysm Trial (ISAT), a randomised multicentre trial to compare coiling with clipping in aSAH patients. Multivariable logistic regression analysis was used to develop a prognostic model to estimate the risk of dying within 60 days from aSAH based on clinical and neuro-imaging characteristics. The model was internally validated with bootstrapping techniques. The study population comprised of 2,128 patients who had been randomised to either endovascular coiling or neurosurgical clipping. In this population 153 patients (7.2%) died within 60 days. World Federation of Neurosurgical Societies (WFNS) grade was the most important predictor of case-fatality, followed by age, lumen size of the aneurysm and Fisher grade. The model discriminated reasonably between those who died within 60 days and those who survived (c statistic = 0.73), with minor optimism according to bootstrap re-sampling (optimism corrected c statistic = 0.70). Several strong predictors are available to predict 60 day case-fatality in aSAH patients who survived the early stage up till a treatment decision; after external validation these predictors could eventually be used in clinical decision making

    Cost-effectiveness of laser Doppler imaging in burn care in the Netherlands

    Get PDF
    textabstractBackground: Early accurate assessment of burn depth is important to determine the optimal treatment of burns. The method most used to determine burn depth is clinical assessment, which is the least expensive, but not the most accurate.Laser Doppler imaging (LDI) is a technique with which a more accurate (>95%) estimate of burn depth can be made by measuring the dermal perfusion. The actual effect on therapeutic decisions, cli

    Cost-effectiveness of laser Doppler imaging in burn care in the Netherlands

    Get PDF
    Background: Early accurate assessment of burn depth is important to determine the optimal treatment of burns. The method most used to determine burn depth is clinical assessment, which is the least expensive, but not the most accurate.Laser Doppler imaging (LDI) is a technique with which a more accurate (>95%) estimate of burn depth can be made by measuring the dermal perfusion. The actual effect on therapeutic decisions, cli
    • …
    corecore