15 research outputs found

    Numerical Simulation of HVAC System Functionality in a Sociocultural Building

    Get PDF
    AbstractThe study presents the functionality of the heating, ventilation and air conditioning (HVAC) system for an important and prestigious objective of Iasi, the “Vasile Alecsandri” National Theatre. A numerical model was created, for the indoor climate analysis, obtaining the main thermal comfort parameters, in different zones of the auditorium. The model carried out on the CFD tool ANSYS-Fluent, is based on the recently implemented HVAC system of the theatre. The results are presented comparatively in two distinct scenarios of the ventilation and conditioning system: when the theatre is occupied and during the breaks. Results from simulation showed that the system provides suitable conditions for occupants and decorative finishing

    Wind tunnel study of natural ventilation of building integrated photovoltaics double skin façade

    No full text
    The paper presents a wind tunnel experimental analysis of a small-scale building model (1:30). The objective of the study is to determine the wind influence on the ventilation of a double skin façade channel (DSF) and the cooling effect over integrated photovoltaic panels. The tests were achieved by conceiving and implementation of an experimental program using a wind tunnel with atmospheric boundary layer. The effect of the wind over the ventilation of the horizontal channels of double skin façades is evaluated for different incident velocities. The results are generalized for the average steady state values of the velocities analysed. The experimental results put in evidence the correlation between the reference wind velocity and the dynamics of the air movement inside the double skin façade. These values are used to determine the convective heat transfer and the cooling effect of the air streams inside the channel upon the integrated photovoltaic panels. The decrease of the photovoltaic panels temperature determines a raise of 11% in efficiency and power generated

    The necessity of HVAC system for the registered architectural cultural heritage building

    No full text
    This study is intended to highlight the role of the ventilation and air conditioning system for a theatre. It was chosen as a case study the "Vasile Alecsandri" National Theatre of Jassy. The paper also sought to make a comparison in three distinct scenarios for HVAC Main Hall system - ventilation and air conditioning system of the Main Hall doesn’t work; only the ventilation system of the Main Hall works and ventilation and air conditioning system of the Main Hall works. For analysing the comfort parameters, the ANSYS-Fluent software was used to build a 2D model of the building and simulation of HVAC system functionality during winter season, in all three scenarios. For the studied scenarios, the external conditions of Jassy and the indoor conditions of the theatre, when the entire spectacle hall is occupied were considered. The main aspects evaluated for each case were the air temperature, air velocity and relative humidity. The results are presented comparatively as plots and spectra of the interest parameters

    The necessity of HVAC system for the registered architectural cultural heritage building

    No full text
    This study is intended to highlight the role of the ventilation and air conditioning system for a theatre. It was chosen as a case study the "Vasile Alecsandri" National Theatre of Jassy. The paper also sought to make a comparison in three distinct scenarios for HVAC Main Hall system - ventilation and air conditioning system of the Main Hall doesn’t work; only the ventilation system of the Main Hall works and ventilation and air conditioning system of the Main Hall works. For analysing the comfort parameters, the ANSYS-Fluent software was used to build a 2D model of the building and simulation of HVAC system functionality during winter season, in all three scenarios. For the studied scenarios, the external conditions of Jassy and the indoor conditions of the theatre, when the entire spectacle hall is occupied were considered. The main aspects evaluated for each case were the air temperature, air velocity and relative humidity. The results are presented comparatively as plots and spectra of the interest parameters

    Wind tunnel study of natural ventilation of building integrated photovoltaics double skin façade

    No full text
    The paper presents a wind tunnel experimental analysis of a small-scale building model (1:30). The objective of the study is to determine the wind influence on the ventilation of a double skin façade channel (DSF) and the cooling effect over integrated photovoltaic panels. The tests were achieved by conceiving and implementation of an experimental program using a wind tunnel with atmospheric boundary layer. The effect of the wind over the ventilation of the horizontal channels of double skin façades is evaluated for different incident velocities. The results are generalized for the average steady state values of the velocities analysed. The experimental results put in evidence the correlation between the reference wind velocity and the dynamics of the air movement inside the double skin façade. These values are used to determine the convective heat transfer and the cooling effect of the air streams inside the channel upon the integrated photovoltaic panels. The decrease of the photovoltaic panels temperature determines a raise of 11% in efficiency and power generated

    Solar protection influence on dynamic insulation efficiency of double skin façades

    No full text
    The objective of the study was to perform a numerical analysis in order to determine the best position for placing sunscreen inside the channel of a double skin façade insulation relative to dynamic insulation efficiency, using ANSYS-Fluent software. The analysis was performed for summer conditions in forced convection for two airspeed regimes inside the channel: 0.2m/s and respectively 0.5m/s. Regime is considered permanent and the only parameter changed is the position of the blinds in the channel. Results are shown by spectra and profiles of temperature and velocity in order to analyse thermodynamic behaviour of a double skin façade. The numerical results emphasize that effectiveness of sunscreen such as blinds, is proportional to the flow velocity inside the channel and inversely proportional to the distance from the outer glazing. Ranked as the most effective sun protection is when it is located at the outer glazing and air velocity at the entrance is 0.5m/s

    Indoor Climate Modelling and Economic Analysis Regarding the Energetic Rehabilitation of a Church

    No full text
    Background: The aim of our study was to identify an optimal heating system for the analyzed church. We also evaluated the energy consumption of the existing system and of those proposed in order to choose the best heating system. Methods: We analyzed the current existing heating system, a mixed system (static heaters and hot air heating) in a Romanian heritage church, build in the 16th century, and we compared it with an underfloor heating system that has been mentioned in the literature as an alternative for church heating. We used a computational fluid dynamics (CFD) analysis of the indoor climate with two turbulence models (k-ε and k-ω). Results: Comparing the two heating systems through boxplot graphs, we could highlight pertinent conclusions regarding the temperatures and velocities of the measured air currents. Thus, of all the heating systems, the underfloor heating had the lowest temperatures, but the highest air velocities, in the churchgoers area, especially under the towers zone. Conclusions: We observed that the underfloor heating system was more efficient than the existing heating system (static heaters and hot air heating), ensuring heritage conservation and high thermal comfort to the churchgoers

    Comparative Numerical Studies on the Structural Behavior of Buried Pipes Subjected to Extreme Environmental Actions

    No full text
    Globally, there are several critical infrastructure networks (water and gas networks) whose disruption or destruction would significantly affect the maintenance of vital societal functions, such as the health, safety, security, and social or economic well-being of people. They would also have significant local, regional, and national impacts as a result of the inability to maintain those functions, and would have similar cross-border effects. The main objective of this article is to investigate by comparative numerical studies the structural response of three types of buried pipes made of different materials, primarily steel, concrete, and high-density polyethylene, resulting from the impact of the environment through exceptional external actions, such as explosions at the surface of the land in the vicinity of the laying areas. The dynamic transient analysis of the equation of motion with the application of the explicit integration procedure was performed with the ANSYS numerical simulation program. This study allows designers to solve complex problems related to the quality of the laying ground of water networks to canals. The knowledge accumulated gives us the possibility to correctly specify the optimal economic and technical value of the ratio between the laying depth of pipes and their diameter, the importance of the radius ratio of the pipe and the thickness of its wall, and, importantly, the improvement of the quality of the foundation ground. Following the results obtained, it is estimated that the optimal economic and technical value of the ratio between the laying depth of the pipes (H) and their diameter (D) is 3, regardless of the material from which the pipe is made
    corecore