2 research outputs found

    Histórico do desenvolvimento e implementação de um sistema nacional de gerenciamento de amostras de produtos em Vigilância Sanitária

    Get PDF
    Introduction: Information is an essential tool for decision-making, and contributes to  the “information-decision-action” process. Objective: To report the National Institute  for Quality Control in Health (INCQS, by its acronym in Portuguese) experience in the development and implementation of a national information system for the management  of samples of products of interest to health - from receipt in the laboratory to the issuance of analytical reports - and to present the possibility of its contribution to the National Health Surveillance System (SNVS). Method: This is a document analysis study on the development and implantation of Harpya (Sample Management System), its evolution and  advances from 1986 to 2020. Access to the system by users, the existence of a centralized database, the implantation in the National Network of Laboratories Health Surveillance (RNLVISA, by its acronym in Portuguese) and the creation and use of nationally standardized catalogs were discussed. Results: The data and information generated by RNLVISA on the quality of products can generate scientific evidence for the identification of risk, being fundamental for the decision-making of managers. In addition, they contribute to the evaluation of laboratories and to the monitoring of market products, subsidizing health surveillance actions. Conclusions: The possibility of accessing data at the national level by different technical areas of the National Health Surveillance Agency stands out, supporting the coordination of the SNVS and also that Harpya’s information can contribute with other information systems in the resolution of public health problems in the country.Introdução: A informação é instrumento essencial para a tomada de decisões, e contribui para o processo “informação-decisão-ação”. Objetivo: Relatar a experiência do Instituto Nacional de Controle de Qualidade em Saúde no desenvolvimento e na implantação de um sistema de informação nacional para o gerenciamento de amostras de produtos de interesse à saúde – do recebimento no laboratório até a emissão dos laudos analíticos – e apresentar a possibilidade de sua contribuição ao Sistema Nacional de Vigilância Sanitária (SNVS). Método: Trata-se de um estudo de análise documental sobre o desenvolvimento e implantação do Harpya, suas evoluções e avanços de 1986 até 2020. O acesso ao sistema pelos usuários, a existência de base de dados centralizada, a implantação na Rede Nacional de Laboratórios de Vigilância Sanitária (RNLVISA) e a criação e utilização de catálogos padronizados nacionalmente foram discutidas. Resultados: Os dados e informações gerados pela RNLVISA sobre a qualidade de produtos podem gerar evidências científicas para a identificação do risco, sendo fundamentais para a tomada de decisões dos gestores. Além disso, contribuem para avaliação dos laboratórios e para o monitoramento dos produtos do mercado, subsidiando as ações de vigilância sanitária. Conclusões: Destacase a possibilidade de acesso aos dados em nível nacional por diferentes áreas técnicas da Agência Nacional de Vigilância Sanitária, subsidiando a coordenação do SNVS e, ainda,  que as informações do Harpya podem contribuir com outros sistemas de informação na resolução dos problemas de saúde pública existentes no país

    Monitoramento pós-mercado dos testes rápidos para COVID-19: enfrentamento da pandemia:

    Get PDF
    Introduction: In December 2019, the  first group of patients with symptoms of atypical pneumonia was discovered in Wuhan, China. On January 7, 2020, the etiologic agent was identified; it was a new betacoronavirus, genetically similar to SARS-CoV-1, consisting of a simple RNA strand, an enveloped virus of 50-200nm in diameter, which was called SARS-CoV-2. Soon after, the disease was named COVID-19. On January 30, WHO declared a Public Health Emergency of International Importance due to the spread of the coronavirus. Tests for serological detection of IgM and IgG antibodies are those that provide an estimate of the immune response to SARS-CoV-2, highlighting the Rapid Diagnostic Tests (RDT), simple and accessible with a result within 5-30 minutes, based on sensitization of antigens/antibodies conjugated to colloidal gold capturing specific proteins present in the infected serum, plasma or blood. Objective: This work aims to show the analysis carried out with RDT for COVID-19 diagnosis in compliance with the current legislation from 02.04 to 18.08.2020. Method: In March of 2020, 25 serum/plasma samples were donated, without any identification. These samples were the remaining samples of tests performed on individuals with a confirmed diagnosis of SARS-CoV-2 infection by the RT-PCR technique from health services (National Institute of Infectious Diseases Evandro Chagas – INI and State Institute of the Brain Paulo Niemeyer – IEC) located in the metropolitan region of the state of Rio de Janeiro. The samples obtained in order to become a serological panel were stored at -20ºC until the moment of use. Simultaneously, a panel of samples with confirmed reactivity for IgM and IgG antibodies from COVID-19 was being made, throughout the pandemic and the samples used were evaluated against three Rapid Tests, of different antigenic compositions or different brands; two ELISA tests for IgM and IgG; two chemiluminescence tests and when applicable, a molecular test. In order to assess the specificity of the products sent, surplus donation plasma samples were selected, known to be negative for HIV, HTLV, hepatitis b and c, chagas and syphilis, collected between 2013 and 2014, in the southern regions of the country, period in which SARS-CoV-2 was nonexistent in the world. In addition to True Positive (VP) and True Negative (VN) samples, interfering serum or plasma samples with reactivity for HIV, HCV, HTLV, HBsAg, chagas disease, syphilis and dengue were also included in the evaluation. Results:  Out of 178 TR lots, 74.1%, 132 lots were from China and 25.9%, 46 TR lots were from Brazil; Germany; South Korea; Canada; USA; Singapore; Ireland and Switzerland. The analytical result showed that 57.0%, 101 TR lots obtained a Satisfactory result and 43%, 77 lots had Unsatisfactory results, when compared to the Sensitivity and Specificity values declared by the manufacturer, in the Instructions for Use. Conclusions:The results obtained show the need for constant monitoring of TRs for COVID-19 with the primary purpose of guaranteeing the quality of products sold in the country, one of the National Health Surveillance System pillars of action.  Introdução: Em dezembro de 2019, foi descoberto na cidade de Wuhan, China, um primeiro grupo de pacientes com sintomas de uma pneumonia atípica. Em 7 de janeiro de 2020, o seu agente etiológico foi identificado: tratava-se de um novo betacoronavírus, geneticamente similar ao SARS-CoV-1, constituído defita simples de RNA, vírus envelopado de 50-200 nm de diâmetro designado como SARS-CoV-2, e a doença foi denominada COVID-19. Em 30 de janeiro, a Organização Mundial da Saúde declarou Emergência de Saúde Pública de Importância Internacional em razão da disseminação desse novo vírus. Os testes para detecção sorológica de anticorpos IgM e IgG fornecem uma estimativa da resposta imune ao SARS-CoV-2, com destaque para os Testes Rápidos (TR) que são simples e acessíveis fornecendo resultados em 5-30 min. Esses testes são sensibilizados com antígenos/anticorpos conjugados ao ouro coloidal, capturando proteínas específicas presentes no soro, plasma ou sangue de pacientes infectados. Objetivo: Demonstrar a análise efetuada nos TR para diagnóstico da COVID-19, em atendimento a legislação vigente, no período de 2 de abril a 18 de agosto de 2020. Método: Durante o mês de março de 2020, foram cedidas 25 amostras de soro/plasma, sem qualquer identificação, excedentes dos testes efetuados em indivíduos com diagnóstico confirmado de infecção pelo SARS-CoV-2 pela técnica de RT-PCR provenientes de serviços de saúde (InstitutoNacional de Infectologia Evandro Chagas – INI e Instituto Estadual do Cérebro Paulo Niemeyer – IEC) localizados na região metropolitana do estado do Rio de Janeiro. As amostras obtidas para a confecção de painel sorológico foram armazenadas a -20ºC até o momento do uso. Concomitantemente, um painel de amostras com reatividade confirmada para anticorpos IgM e IgG da COVID-19 foi sendo confeccionado ao longo da pandemia e as amostras utilizadas foram avaliadas frente a três TR, de diferentes composições antigênicas ou diferentes marcas; dois testes ELISA para IgM e IgG; dois testes de quimioluminescência e quando aplicável, um teste molecular. Para avaliação da especificidade dos produtos encaminhados, foram selecionadas amostras de plasma excedentes de doação, sabidamente negativas para HIV, HTLV, hepatite B e C, doença de chagas e sífilis coletadas nos anos de 2013 e 2014, na Região Sul do país, período no qual o SARS-CoV-2 era inexistente. Além de amostras Verdadeiro Positivas (VP) e Verdadeiro Negativas (VN), ainda foram incluídas na avaliação amostras de soro ou plasma interferentes com reatividade para HIV, HCV, HTLV, HBsAg, doença de chagas, sífilis e dengue. Resultados:  Dos 178 lotes de TR, 74,1% foram provenientes da China e 25,9%, do Brasil, da Alemanha, da Coreia do Sul, do Canadá, dos EUA, da Cingapura,da Irlanda e da Suíça. O resultado analítico demonstrou que 57,0% dos TR obtiveram resultados satisfatórios e 43,0%, resultados insatisfatórios, quando comparados aos valores de sensibilidade e especificidade declarados pelo fabricante na instrução de uso. Conclusões: Há necessidade de constante monitoramento dos TR para COVID-19, com finalidade precípua de garantir a qualidade dos produtos comercializados no país, um dos pilares das ações do Sistema Nacional de Vigilância Sanitária
    corecore