120 research outputs found

    Stokes-correlometry analysis of biological tissues with polycrystalline structure

    Get PDF
    Utilizing Stokes-correlometry analysis a new diagnostic approach has been introduced for quantitative assessment of polarization images of histological sections of optically anisotropic biological tissues with different morphological structures and physiological conditions. The developed approach is based on the quantitative assessment of coordinate and phase distributions of the Stokes vector of scattered light. A combined use of statistic, correlation, and fractal analysis is used for resolving variations in optical anisotropy of biological samples. The proposed combined application of the statistical, correlation, and fractal-based evaluates of spatial distributions of `single-point' polarization azimuth, ellipticity, and `two-point' Stokes vector parameters of polarization images of biological tissues histological sections demonstrates a high accuracy (Ac ≥ 90%) in monitoring of optical anisotropy variations within biological tissues

    Studying temporal variability of GRS1739-278 during the 2014 outburst

    Get PDF
    We report a discovery of low-frequency quasi periodic oscillation at 0.3-0.7 Hz in the power spectra of the accreting black hole GRS1739-278 in the hard-intermediate state during its 2014 outburst based on the NuSTAR{\it NuSTAR} and Swift/XRT data. The QPO frequency strongly evolved with the source flux during the NuSTAR observation. The source spectrum became softer with rising QPO frequency and simultaneous increasing of the power-law index and decreasing of the cut-off energy. In the power spectrum, a prominent harmonic is clearly seen together with the main QPO peak. The fluxes in the soft and the hard X-ray bands are coherent, however, the coherence drops for the energy bands separated by larger gaps. The phase-lags are generally positive (hard) in the 0.1-3 Hz frequency range, and negative below 0.1 Hz. The accretion disc inner radius estimated with the relativistic reflection spectral model appears to be Rin<7.3RgR_{\rm in} < 7.3 R_{\rm g}. In the framework of the relativistic precession model, in order to satisfy the constraints from the observed QPO frequency and the accretion disc truncation radius, a massive black hole with MBH100M_{\rm BH} \approx 100M_\odot is required.Comment: 15 pages, 12 figures; accepted for publication in MNRA

    Combined use of laser Doppler flowmetry and skin thermometry for functional diagnostics of intradermal finger vessels

    Get PDF
    We introduce a noninvasive diagnostic approach for functional monitoring of blood microflows in capillaries and thermoregulatory vessels within the skin. The measuring system is based on the combined use of laser Doppler flowmetry and skin contact thermometry. The obtained results suggest that monitoring of blood microcirculation during the occlusion, performed in conjunction with the skin temperature measurements in the thermally stabilized medium, has a great potential for quantitative assessment of angiospatic dysfunctions of the peripheral blood vessels. The indices of blood flow reserve and temperature response were measured and used as the primarily parameters of the functional diagnostics of the peripheral vessels of skin. Utilizing these parameters, a simple phenomenological model has been suggested to identify patients with angiospastic violations in the vascular system

    Mapping of polycrystalline films of biological fluids utilizing the Jones-matrix formalism

    Get PDF
    Utilizing a polarized light approach, we reconstruct the spatial distribution of birefringence and optical activity in polycrystalline films of biological fluids. The Jones-matrix formalism is used for an accessible quantitative description of these types of optical anisotropy. We demonstrate that differentiation of polycrystalline films of biological fluids can be performed based on a statistical analysis of the distribution of rotation angles and phase shifts associated with the optical activity and birefringence, respectively. Finally, practical operational characteristics, such as sensitivity, specificity and accuracy of the Jones-matrix reconstruction of optical anisotropy, were identified with special emphasis on biomedical application, specifically for differentiation of bile films taken from healthy donors and from patients with cholelithiasis

    Advances in Dynamic Light Scattering Imaging of Blood Flow

    Get PDF
    Dynamic light scattering (DLS) is a well known experimental approach uniquely suited for the characterization of small particles undergoing Brownian motion in randomly inhomogeneous turbid scattering medium, including water suspension, polymers in solutions, cells cultures, and so on. DLS is based on the illuminating of turbid medium with a coherent laser light and further analyzes the intensity fluctuations caused by the motion of the scattering particles. The DLS-based spin-off derivative techniques, such laser Doppler flowmetry (LDF), diffusing wave spectroscopy (DWS), laser speckle contrast imaging (LSCI), and Doppler optical coherence tomography (DOCT), are exploited widely for non-invasive imaging of blood flow in brain, skin, muscles, and other biological tissues. The recent advancements in the DLS-based imaging technologies in frame of their application for brain blood flow monitoring, skin perfusion measurements, and non-invasive blood micro-circulation characterization are overviewed. The fundamentals, breakthrough potential, and practical findings revealed by DLS-based blood flow imaging studies, including the limitations and challenges of the approach such as movement artifacts, non-ergodicity, and overcoming high scattering properties of studied medium, are also discussed. It is concluded that continued research and further technological advancements in DLS-based imaging will pave the way for new exciting developments and insights into blood flow diagnostic imaging

    Multimodal optical measurement for study of lower limb tissue viability in patients with diabetes mellitus

    Get PDF
    According to the International Diabetes Federation, the challenge of early stage diagnosis and treatment effectiveness monitoring in diabetes is currently one of the highest priorities in modern healthcare. The potential of combined measurements of skin fluorescence and blood perfusion by the laser Doppler flowmetry method in diagnostics of low limb diabetes complications was evaluated. Using Monte Carlo probabilistic modeling, the diagnostic volume and depth of the diagnosis were evaluated. The experimental study involved 76 patients with type 2 diabetes mellitus. These patients were divided into two groups depending on the degree of complications. The control group consisted of 48 healthy volunteers. The local thermal stimulation was selected as a stimulus on the blood microcirculation system. The experimental studies have shown that diabetic patients have elevated values of normalized fluorescence amplitudes, as well as a lower perfusion response to local heating. In the group of people with diabetes with trophic ulcers, these parameters also significantly differ from the control and diabetes only groups. Thus, the intensity of skin fluorescence and level of tissue blood perfusion can act as markers for various degrees of complications from the beginning of diabetes to the formation of trophic ulcers

    Insights into polycrystalline microstructure of blood films with 3D Mueller matrix imaging approach

    Get PDF
    This study introduces a novel approach in the realm of liquid biopsies, employing a 3D Mueller-matrix (MM) image reconstruction technique to analyze dehydrated blood smear polycrystalline structures. Our research centers on exploiting the unique optical anisotropy properties of blood proteins, which undergo structural alterations at the quaternary and tertiary levels in the early stages of diseases such as cancer. These alterations manifest as distinct patterns in the polycrystalline microstructure of dried blood droplets, offering a minimally invasive yet highly effective method for early disease detection. We utilized a groundbreaking 3D MM mapping technique, integrated with digital holographic reconstruction, to perform a detailed layer-by-layer analysis of partially depolarizing dry blood smears. This method allows us to extract critical optical anisotropy parameters, enabling the differentiation of blood films from healthy individuals and prostate cancer patients. Our technique uniquely combines polarization-holographic and differential MM methodologies to spatially characterize the 3D polycrystalline structures within blood films. A key advancement in our study is the quantitative evaluation of optical anisotropy maps using statistical moments (first to fourth orders) of linear and circular birefringence and dichroism distributions. This analysis provides a comprehensive characterization of the mean, variance, skewness, and kurtosis of these distributions, crucial for identifying significant differences between healthy and cancerous samples. Our findings demonstrate an exceptional accuracy rate of over 90% for the early diagnosis and staging of cancer, surpassing existing screening methods. This high level of precision and the non-invasive nature of our technique mark a significant advancement in the field of liquid biopsies. It holds immense potential for revolutionizing cancer diagnosis, early detection, patient stratification, and monitoring, thereby greatly enhancing patient care and treatment outcomes. In conclusion, our study contributes a pioneering technique to the liquid biopsy domain, aligning with the ongoing quest for non-invasive, reliable, and efficient diagnostic methods. It opens new avenues for cancer diagnosis and monitoring, representing a substantial leap forward in personalized medicine and oncology
    corecore