93 research outputs found

    Early QCD measurements with ATLAS

    Get PDF
    This paper describes some of the QCD measurements that ATLAS will make using data from the Large Hadron Collider (LHC). Studies of minimum bias events and the underlying event that can be made with the first LHC data are presented. The determination of the jet energy scale of high Pt jets is discussed

    A Study of the Reaction e+e- → mu+mu- Using the CELLO Detector

    Get PDF
    A study was made of the reaction e+e- → mu+mu- using the CELLO detector at PETRA. Using data collected at a centre of mass energy of 35 GeV the total cross section, sigma0 and the electroweak charge asymmetry. Afb were measured giving: Rmumu =sigma0/sigmaQED = 0.95+/-0.02+/-0.05; Afb = -8.9+/-2.0+/-1.0 % The results are in good agreement with the values predicted by the electroweak model of Rmumu = 1.0 and Afb = -8.9% at this energy. Using data collected at a centre of mass energy of 43 GeV a search was made for acoplanar muon pairs, a signature of scalar muons. No candidates were found and the following masses were excluded at the 95% C. L

    Low Noise and High Photodetection Probability SPAD in 180 nm Standard CMOS Technology

    Get PDF
    A square shaped, low noise and high photo-response single photon avalanche diode suitable for circuit integration, implemented in a standard CMOS 180 nm high voltage technology, is presented. In this work, a p+ to shallow n-well junction was engineered with a very smooth electric field profile guard ring to attain a photo detection probability peak higher than 50% with a median dark count rate lower than 2 Hz/ÎĽm2 when operated at an excess bias of 4 V. The reported timing jitter full width at half maximum is below 300 ps for 640 nm laser pulses

    Mapping the depleted area of silicon diodes using a micro-focused X-ray beam

    Full text link
    For the Phase-II Upgrade of the ATLAS detector at CERN, the current ATLAS Inner Detector will be replaced with the ATLAS Inner Tracker. The ATLAS Inner Tracker will be an all-silicon detector, consisting of a pixel tracker and a strip tracker. Sensors for the ITk strip tracker are required to have a low leakage current up to bias voltages of -700 V to maintain a low noise and power dissipation. In order to minimise sensor leakage currents, particularly in the high-radiation environment inside the ATLAS detector, sensors are foreseen to be operated at low temperatures and to be manufactured from wafers with a high bulk resistivity of several k{\Omega} cm. Simulations showed the electric field inside sensors with high bulk resistivity to extend towards the sensor edge, which could lead to increased surface currents for narrow dicing edges. In order to map the electric field inside biased silicon sensors with high bulk resistivity, three diodes from ATLAS silicon strip sensor prototype wafers were studied with a monochromatic, micro-focused X-ray beam at the Diamond Light Source. For all devices under investigation, the electric field inside the diode was mapped and its dependence on the applied bias voltage was studied. The findings showed that the electric field in each diode under investigation extended beyond its bias ring and reached the dicing edge

    Modeling of Charge Transfer Inefficiency in a CCD with High Speed Column Parallel Readout

    Full text link
    Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived particles. The Linear Collider Flavour Identification (LCFI) collaboration is developing Column-Parallel CCDs (CPCCDs) for the vertex detector of a future Linear Collider. The CPCCDs can be read out many times faster than standard CCDs, significantly increasing their operating speed. An Analytic Model has been developed for the determination of the charge transfer inefficiency (CTI) of a CPCCD. The CTI values determined with the Analytic Model agree largely with those from a full TCAD simulation. The Analytic Model allows efficient study of the variation of the CTI on parameters like readout frequency, operating temperature and occupancy.Comment: 5 pages, 13 figures, presented on behalf of the LCFI Collaboration, proceedings IEEE 2008 Nuclear Science Symposium, Dresden, Germany, and 11th Topical Seminar on Innovative Particle and Radiation Detectors (IPRD08) 2008, Siena, Ital

    A 64x64 SPAD array for portable colorimetric sensing, fluorescence and X-ray imaging

    Get PDF
    We present the design and application of a 64x64 pixel SPAD array to portable colorimetric sensing, and fluorescence and x-ray imaging. The device was fabricated on an unmodified 180 nm CMOS process and is based on a square p+/n active junction SPAD geometry suitable for detecting green fluorescence emission. The stand-alone SPAD shows a photodetection probability greater than 60% at 5 V excess bias, with a dark count rate of less than 4 cps/µm2 and sub-ns timing jitter performance. It has a global shutter with an in-pixel 8-bit counter; four 5-bit decoders and two 64-to-1 multiplexer blocks allow the data to be read-out. The array of sensors was able to detect fluorescence from a fluorescein isothiocyanate (FITC) solution down to a concentration of 900 pM with a SNR of 9.8 dB. A colorimetric assay was performed on top of the sensor array with a limit of quantification of 3.1 µM. X-rays images, using energies ranging from 10 kVp to 100 kVp, of a lead grating mask were acquired without using a scintillation crystal

    Radiation hardness of MALTA2 monolithic CMOS imaging sensors on Czochralski substrates

    Get PDF
    MALTA2 is the latest full-scale prototype of the MALTA family of Depleted Monolithic Active Pixel Sensors (DMAPS) produced in Tower Semiconductor 180 nm CMOS sensor imaging technology. In order to comply with the requirements of high energy physics (HEP) experiments, various process modifications and front-end changes have been implemented to achieve low power consumption, reduce random telegraph signal (RTS) noise, and optimise the charge collection geometry. Compared to its predecessors, MALTA2 targets the use of a high-resistivity, thick Czochralski (Cz) substrates in order to demonstrate radiation hardness in terms of detection efficiency and timing resolution up to 3 Ă— 1015 1 MeV neq/cm2 with backside metallisation to achieve good propagation of the bias voltage. This manuscript shows the results that were obtained with non-irradiated and irradiated MALTA2 samples on Cz substrates from the CERN SPS test beam campaign from 2021 to 2023 using the MALTA telescope

    Performance of the MALTA Telescope

    Get PDF
    MALTA is part of the Depleted Monolithic Active Pixel sensors designed in Tower 180nm CMOS imaging technology. A custom telescope with six MALTA planes has been developed for test beam campaigns at SPS, CERN, with the ability to host several devices under test. The telescope system has a dedicated custom readout, online monitoring integrated into DAQ with realtime hit map, time distribution and event hit multiplicity. It hosts a dedicated fully configurable trigger system enabling to trigger on coincidence between telescope planes and timing reference from a scintillator. The excellent time resolution performance allows for fast track reconstruction, due to the possibility to retain a low hit multiplicity per event which reduces the combinatorics. This paper reviews the architecture of the system and its performance during the 2021 and 2022 test beam campaign at the SPS North Area

    Latest developments and characterisation results of DMAPS in TowerJazz 180nm for High Luminosity LHC

    Get PDF
    The last couple of years have seen the development of Depleted Monolithic Active Pixel Sensors (DMAPS) fabricated in TowerJazz 180nm with a process modification to increase the radiation tolerance. While many of MAPS developments focus on low radiation environment, we have taken the development to high radiation environment like pp-experiments at High Luminosity LHC. DMAPS are a cost effective and lightweight alternative to state-of-the-art hybrid detectors if they can fulfil the given requirements for radiation hardness, signal response time and hit rate capability. The MALTA and Mini-MALTA sensors have shown excellent detection efficiency after irradiation to the life time dose expected at the outer layers of the ATLAS pixel tracker Upgrade. Our development focuses on providing large pixel matrixes with excellent time resolution (<2ns) and tracking. This publication will discuss characterisation results of the DMAPS devices with special focus on the new MALTA2 sensor and will show the path of future development
    • …
    corecore