10 research outputs found

    Colorectal cancer screening with faecal immunochemical testing, sigmoidoscopy or colonoscopy: a microsimulation modelling study

    Get PDF
    OBJECTIVE: To estimate benefits and harms of different colorectal cancer screening strategies, stratified by (baseline) 15-year colorectal cancer risk. DESIGN: Microsimulation modelling study using MIcrosimulation SCreening ANalysis-Colon (MISCAN-Colon). SETTING: A parallel guideline committee (BMJ Rapid Recommendations) defined the time frame and screening interventions, including

    The second round of the Dutch colorectal cancer screening program: Impact of an increased fecal immunochemical test cut-off level on yield of screening

    Get PDF
    The Dutch colorectal cancer (CRC) screening program started in 2014, inviting the target population biennially to perform a fecal immunochemical test (FIT). We obtained prospectively collected data from the national screening information-system to present the results of the second round (2016) and evaluate the impact of increasing the FIT cut-off halfway through the first round from 15 to 47 ÎĽg Hb/g feces on outcomes in the second round. Second round screening was done with a 47 ÎĽg Hb/g feces FIT cut-off. Participants were classified based on first round participation status as either FIT (15,47) or FIT (47,47) participants, and previous nonparticipants. In total, 348,891 (75.9%) out of 459,740 invitees participated in the second round. Participation rates were 93.4% among previous participants and 21.0% among previous non-participants. FIT(47,47) participants had a significantly higher detection rate of AN (15.3 vs. 10.4 per 1,000 participants) compared to FIT(15,47) participants in the second round, while their cumulative detection rate of AN over two rounds was significantly lower (45.6 vs. 52.6 per 1,000 participants). Our results showed that participation in the Dutch CRC screening program was consistently high and that second round detection rates depended on the first round FIT cut-off. The cumulative detection over two rounds was higher among FIT(15,47) participants. These findings suggest that a substantial part of, but not all the missed findings in the first round due to the increased FIT cut-off were detected in the subsequent round

    Development and Validation of Three Regional Microsimulation Models for Predicting Colorectal Cancer Screening Benefits in Europe

    Get PDF
    Background. Validated microsimulation models have been shown to be useful tools in providing support for colorec- tal cancer (CRC) screening decisions. Aiming to assist European countries in reducing CRC mortality, we developed and validated three regional models for evaluating CRC screening in Europe. Methods. Microsimulation Screening Analysis–Colon (MISCAN-Colon) model versions for Italy, Slovenia, and Finland were quantified using data from different national institutions. These models were validated against the best available evidence for the effectiveness of screening from their region (when available): the Screening for COlon REctum (SCORE) trial and the Florentine fecal immunochemical test (FIT) screening study for Italy; the Norwegian Colorectal Cancer Prevention (NORCCAP) trial and the guaiac fecal occult blood test (gFOBT) Finnish population-based study for Finland. When published evidenc

    The impact of information about different absolute benefits and harms on intention to participate in colorectal cancer screening: A think-aloud study and online randomised experiment

    Get PDF
    Background There is considerable heterogeneity in individuals’ risk of disease and thus the absolute benefits and harms of population-wide screening programmes. Using colorectal cancer (CRC) screening as an exemplar, we explored how people make decisions about screening when presented with information about absolute benefits and harms, and how those preferences vary with baseline risk, between screening tests and between individuals. Method We conducted two linked studies with members of the public: a think-aloud study exploring decision making in-depth and an online randomised experiment quantifying preferences. In both, participants completed a web-based survey including information about three screening tests (colonoscopy, sigmoidosc

    Colonoscopy-Related Mortality in a Fecal Immunochemical Test–Based Colorectal Cancer Screening Program

    No full text
    Background &amp; Aims: Many countries have introduced colorectal cancer (CRC) screening programs with fecal immunochemical tests (FITs), and follow-up colonoscopies for individuals with a positive FIT result. In order to make an informed decision to participate, individuals must be informed about the benefits and harms of FIT-based screening and subsequent colonoscopy. Colonoscopy-related fatal complications in FIT-based screening are understudied. We aimed to estimate the colonoscopy-related mortality in a national FIT-based CRC screening program. Methods: Colonoscopy-related mortality within 30 days after colonoscopy was assessed by analysis of data from national endoscopy complication databases in the Netherlands, determining the excess 30-day rate of death in FIT-positive individuals undergoing colonoscopy vs FIT-negative individuals (based on data from the national screening database), and determining the rate of likely colonoscopy-related deaths based on registered causes of death by the Statistics Netherlands. Results: Between October 2013 and December 2017, 172,797 participants underwent colonoscopy after a positive result from a FIT in the Dutch national CRC screening program; 13,848 participants received a diagnosis of CRC. The reported fatal complication rate was 0.23 per 10,000 FIT-positive participants (or 1 per 43,199; 95% CI, 0.090 – 0.60) undergoing colonoscopy, whereas this was 0.91 per 10,000 FIT-positive participants (or 1 per 10,961; 95% CI, 0.44 – 1.38) according to the excess death rate. Likely colonoscopy-related causes of death were reported in 0.86 per 10,000 FIT-positive participants (or 1 per 11,236; 95% CI, 0.48 – 1.63) who underwent colonoscopy, of which 50% considered cardiovascular events. Conclusions: Colonoscopy-related mortality within the Dutch FIT-based CRC screening program was estimated to range from 0.23 to 0.91 per 10,000 FIT-positive participants undergoing colonoscopy. These findings indicate underreporting of fatal complications in registries and a noteworthy incidence of fatal cardiovascular adverse events that requires further investigation. Nevertheless, the harm of FIT-based CRC screening is vastly outweighed by the benefits.</p

    Quality monitoring of a fit-based colorectal cancer screening program

    No full text
    BACKGROUND: Quality assessment is crucial for consistent program performance of colorectal cancer (CRC) screening programs using fecal immunochemical test for hemoglobin (FIT). However, literature on the consistency of FIT performance in laboratory medicine was lacking. This study examined the consistency of FIT in testing positive or detecting advanced neoplasia (AN) for different specimen collection devices, lot reagents, and laboratories. METHODS: All participants with a FIT sample with a cutoff concentration of 47 g Hb/g feces in the Dutch CRC screening program in 2014 and 2015 were included in the analyses. Multivariable logistic regression analyses were performed to estimate the odds ratios of collection devices, reagents, and laboratories on testing positive or detecting AN and positive predictive value (PPV). RESULTS: In total, 87 519 (6.4%) of the 1 371 169 participants tested positive. Positivity rates and detection rates of AN differed between collection devices and reagents (all P 0.01). In contrast, PPVs were not found to vary between collection devices, reagents, or laboratories (all P 0.05). Positivity rates showed a small difference for laboratories (P 0.004) but not for detection rates of AN. Size of the population affected by the deviating positivity rates was small (0.1% of the total tested population). CONCLUSIONS: Variations were observed in positivity and detection rates between collection devices and reagents, but there was no detected variation in PPV. Although the overall population effect of these variations on the screened population is expected to be modest, there is room for improvement
    corecore