30 research outputs found

    Controversies Surrounding Renal Denervation:Lessons Learned From Real-World Experience in Two United Kingdom Centers

    Get PDF
    Renal denervation (RDN) is a therapy that targets treatment‐resistant hypertension (TRH). The Renal Denervation in Patients With Uncontrolled Hypertension (Symplicity) HTN‐1 and Symplicity HTN‐2 trials reported response rates of >80%; however, sham‐controlled Symplicity HTN‐3 failed to reach its primary blood pressure (BP) outcome. The authors address the current controversies surrounding RDN, illustrated with real‐world data from two centers in the United Kingdom. In this cohort, 52% of patients responded to RDN, with a 13±32 mm Hg reduction in office systolic BP (SBP) at 6 months (n=29, P=.03). Baseline office SBP and number of ablations correlated with office SBP reduction (R=−0.47, P=.01; R=−0.56, P=.002). RDN appears to be an effective treatment for some patients with TRH; however, individual responses are highly variable. Selecting patients for RDN is challenging, with only 10% (33 of 321) of the screened patients eligible for the study. Medication alterations and nonadherence confound outcomes. Adequate ablation is critical and should impact future catheter design/training. Markers of procedural success and improved patient selection parameters remain key research aims

    Cardiovascular magnetic resonance imaging of myocardial oedema following acute myocardial infarction: Is whole heart coverage necessary?

    Get PDF
    © 2016 Hamshere et al. Background: AAR measurement is useful when assessing the efficacy of reperfusion therapy and novel cardioprotective agents after myocardial infarction. Multi-slice (Typically 10-12) T2-STIR has been used widely for its measurement, typically with a short axis stack (SAX) covering the entire left ventricle, which can result in long acquisition times and multiple breath holds. This study sought to compare 3-slice T2-short-tau inversion recovery (T2- STIR) technique against conventional multi-slice T2-STIR technique for the assessment of area at risk (AAR). Methods: CMR imaging was performed on 167 patients after successful primary percutaneous coronary intervention. 82 patients underwent a novel 3-slice SAX protocol and 85 patients underwent standard 10-slice SAX protocol. AAR was obtained by manual endocardial and epicardial contour mapping followed by a semi- automated selection of normal myocardium; the volume was expressed as mass (%) by two independent observers. Results: 85 patients underwent both 10-slice and 3-slice imaging assessment showing a significant and strong correlation (intraclass correlation coefficient = 0.92;p < 0.0001) and a low Bland-Altman limit (mean difference -0.03 ± 3.21 %, 95 % limit of agreement,- 6.3 to 6.3) between the 2 analysis techniques. A further 82 patients underwent 3-slice imaging alone, both the 3-slice and the 10-slice techniques showed statistically significant correlations with angiographic risk scores (3-slice to BARI r = 0.36, 3-slice to APPROACH r = 0.42, 10-slice to BARI r = 0.27, 10-slice to APPROACH r = 0.46). There was low inter-observer variability demonstrated in the 3-slice technique, which was comparable to the 10-slice method (z = 1.035, p = 0.15). Acquisition and analysis times were quicker in the 3-slice compared to the 10-slice method (3-slice median time: 100 seconds (IQR: 65-171 s) vs (10-slice time: 355 seconds (IQR: 275-603 s); p < 0.0001. Conclusions: AAR measured using 3-slice T2-STIR technique correlates well with standard 10-slice techniques, with no significant bias demonstrated in assessing the AAR. The 3-slice technique requires less time to perform and analyse and is therefore advantageous for both patients and clinicians
    corecore