213 research outputs found

    Endoscopic off-pump aortic valve replacement: does the pericardial cuff improve the sutureless closure of left ventricular access?

    Get PDF
    Objective: Off-pump trans left ventricular approach provides more precise deployment of stented aortic valve of any size with respect to the endovascular replacement. One of the key steps of this procedure is the ventricle repair after catheter withdrawing. We designed an animal study to compare the consistency of a sutureless repair of the left ventricle access using nitinol occluder with and without pericardial cuff on the ventricular side. Methods: Material description: The Amplatz-nitinol occluder consists of two square heads squeezing ventricle wall in between them, sealing the defect. To improve its sealing property, a pericardial patch was sutured to the ventricular head of the occluder. Animal study setup: In adult pigs, a 30F sheath was inserted into the epigastric area through the cardiac apex, up to the left ventricle, simulating the approach for off-pump aortic valve replacement. The sheath was then removed and the ventricle closed with standard occluder in half of the animals, and cuffed occluder in the other half. Animals were followed-up for 3h, collecting haemodynamics data and pericardial bleeding. Results: Device was successfully deployed in 12 animals in less than 1min. In the group where the standard occluder was used, bleeding during the deployment was 80±20ml and after the deployment was 800±20ml over 3h. In the group where the cuffed occluder was used, bleeding during the deployment was 85±20ml and after the deployment was 100±5ml over 3h. In the cuffed group, bleeding was significantly lower than the standard group, p-value being ≪0.001. Conclusions: The occluder is easy to use and the pericardial cuff dramatically increases its efficacy as demonstrated by a significant reduction of blood loss. The cuffed occluder opens the way for endoscopic, off-pump, transventricular aortic valve replacemen

    Endoscopic access closure for direct implantation of valved stents

    Get PDF
    OBJECTIVES: The off-pump trans left ventricular approach provides an alternative option for insertion of stented aortic valves of any size for endovascular replacement. One of the key steps in this procedure is the repair of the ventricle after catheter withdrawal. This study evaluates the reliability of a new device for sutureless and quick repair of the left ventricle access. METHODS: The Amplatz-nitinol occluder consists of two square heads that squeeze the ventricle wall between them thus sealing the ventricular defect. In four adult pigs weighing 55 kg, left thoracoscopy was performed to open the pericardium and visualise the cardiac apex. Following a heparin injection (100 U/kg) under ICUS and fluoroscopic control, we inserted a 30 F sheath into the epigastric area through the cardiac apex up into the left ventricle thus simulating the approach for an off-pump aortic valve replacement. The sheath was then removed and the ventricle closed with the occluder. Animals were followed-up for three hours; the haemodynamics and pericardial bleeding were recorded. The animals were then sacrificed and the gross anatomy of the heart was examined. RESULTS: The device was successfully deployed in four animals in less than one minute. ACT was above 200 seconds in all cases. All animals survived the procedure with a mean arterial pressure of 50 +/- 15 mm Hg. Bleeding during deployment was 80 +/- 20 ml and over a 3 hour period was 800 +/- 20 ml. Examination of the gross anatomy examination demonstrated the correct positioning of the device. CONCLUSIONS: The occluder is easy to use and the procedure is feasible and reproducible. However, the occluder design requires technical improvements in order to reduce bleeding before it can be used clinically

    Analysis of filtration processes in small experimental embankment based on numerical modeling and temperature measurements

    Get PDF
    Abstract This paper presents analysis of filtration processes in small experimental embankment. The analysis is based on field measurements and numerical modeling. The measurements were performed on experimental embankment, which size is in scale 1:5 comparing to typical river embankments in Poland. The measurements are made during flooding experiment. Two parameters during experiment ware measured: pore pressure and temperature. Additionally, the thermograpical observation of air side of embankment was conducted. The FLAC 7.0 software was used in 2D numerical modeling. Modification the parameters of the model allowed to fit the modelled data to the measured data

    Closure of left ventricle perforation with the use of muscular VSD occluder

    Get PDF
    Growing experience in interventional cardiology leads to the use of large diameter of vascular equipment. In some instances, the so-called hybrid procedures are performed. After performing the interventional procedure, the opening in ventricular wall is closed surgically. Our intention was to check if the MVSDO can be used to close the perforation in the heart after the interventional cardiology procedure performed through the left ventricular (LV) free wall. In three pigs under general anesthesia, the heart was exposed through a small substernal incision. The LV was punctured and an 18F sheath was introduced into the LV. A 14 mm MVSDO was inserted through the 10F Delivery System. Using both the echocardiographic and angiographic guidance, the MVSDO was placed on the LV wall to close the opening in the LV. Time and volume of bleeding was recorded. In all cases the occluder was successfully placed closing the opening, bleeding observed after deployment of occluder lasted for approximately 2 min. We think MVSD occluder can be used to close the LV free wall perforation after hybrid interventional cardiac procedure. Early bleeding through MVSDO might be resolved by the manufacturing of new occluder with better sealing properties

    Oxidative stress biomarkers and acetylcholinesterase activity in human erythrocytes exposed to clomazone (in vitro)

    Get PDF
    The aim of this study was to investigate the effect of clomazone herbicide on oxidative stress biomarkers and acetylcholinesterase activity in human erythrocytes in in vitro conditions. The activity of catalase (CAT), superoxide dismutase (SOD) and acetylcholinesterase (AChE), as well as the levels of thiobarbituric acid reactive substances (TBARS) and reduced glutathione (GSH) were measured in human erythrocytes exposed (in vitro) to clomazone at varying concentrations in the range of 0, 100, 250 and 500 µg/L for 1 h at 37 °C.TBARS levels were significantly higher in erythrocytes incubated with clomazone at 100, 250 and 500 µg/L. However, erythrocyte CAT and AChE activities were decreased at all concentrations tested. SOD activity was increased only at 100 µg/L of clomazone. GSH levels did not change with clomazone exposure. These results clearly showed clomazone to induce oxidative stress and AChE inhibition in human erythrocytes (in vitro). We, thus, suggest a possible role of ROS on toxicity mechanism induced by clomazone in humans

    Position effects at the FGF8 locus are associated with femoral hypoplasia

    Get PDF
    Copy-number variations (CNVs) are a common cause of congenital limb malformations and are interpreted primarily on the basis of their effect on gene dosage. However, recent studies show that CNVs also influence the 3D genome chromatin organization. The functional interpretation of whether a phenotype is the result of gene dosage or a regulatory position effect remains challenging. Here, we report on two unrelated families with individuals affected by bilateral hypoplasia of the femoral bones, both harboring de novo duplications on chromosome 10q24.32. The ∼0.5 Mb duplications include FGF8, a key regulator of limb development and several limb enhancer elements. To functionally characterize these variants, we analyzed the local chromatin architecture in the affected individuals’ cells and re-engineered the duplications in mice by using CRISPR-Cas9 genome editing. We found that the duplications were associated with ectopic chromatin contacts and increased FGF8 expression. Transgenic mice carrying the heterozygous tandem duplication including Fgf8 exhibited proximal shortening of the limbs, resembling the human phenotype. To evaluate whether the phenotype was a result of gene dosage, we generated another transgenic mice line, carrying the duplication on one allele and a concurrent Fgf8 deletion on the other allele, as a control. Surprisingly, the same malformations were observed. Capture Hi-C experiments revealed ectopic interaction with the duplicated region and Fgf8, indicating a position effect. In summary, we show that duplications at the FGF8 locus are associated with femoral hypoplasia and that the phenotype is most likely the result of position effects altering FGF8 expression rather than gene dosage effects.M.S. and A.S.-S. were supported by the Polish National Science Centre (UMO-2016/23/N/NZ2/02362 to M.S. and UMO-2016/21/D/NZ5/00064 to A.S.-S.). A.S.-S. was also supported by the Polish National Science Centre scholarship for PhD students (UMO-2013/08/T/NZ2/00027). C.L. is supported by postdoctoral Beatriu de Pinós from Secretaria d’Universitats I Recerca del Departament d’Empresa i Coneixement de la Generalitat de Catalunya and by the Marie Sklodowska-Curie COFUND program from H2020 (2018-BP-00055). A.J. was supported by the Polish National Science Centre (UMO-2016/22/E/NZ5/00270) as well as the Polish National Centre for Research and Development (LIDER/008/431/L-4/12/NCBR/2013). M.S. is supported by grants from the Deutsche Forschungsgemeinschaft (DFG) (SP1532/3-1, SP1532/4-1, and SP1532/5-1), the Max Planck Foundation, and the Deutsches Zentrum für Luft- und Raumfahrt (DLR 01GM1925)

    Effects of rose hip intake on risk markers of type 2 diabetes and cardiovascular disease: a randomized, double-blind, cross-over investigation in obese persons

    Get PDF
    BACKGROUND/OBJECTIVES:In studies performed in mice, rose hip powder has been shown to both prevent and reverse high-fat diet-induced obesity and glucose intolerance as well as reduce plasma levels of cholesterol. The aim of this study was to investigate whether daily intake of rose hip powder over 6 weeks exerts beneficial metabolic effects in obese individuals.SUBJECTS/METHODS:A total of 31 obese individuals with normal or impaired glucose tolerance were enrolled in a randomized, double-blind, cross-over study in which metabolic effects of daily intake of a rose hip powder drink over 6 weeks was compared with a control drink. Body weight, glucose tolerance, blood pressure, blood lipids and markers of inflammation were assessed in the subjects.RESULTS:In comparison with the control drink, 6 weeks of daily consumption of the rose hip drink resulted in a significant reduction of systolic blood pressure (-3.4%; P=0.021), total plasma cholesterol (-4.9%; P=0.0018), low-density lipoprotein (LDL) cholesterol (-6.0%; P=0.012) and LDL/HDL ratio (-6.5%; P=0.041). The Reynolds risk assessment score for cardiovascular disease was decreased in the rose hip group compared with the control group (-17%; P=0.007). Body weight, diastolic blood pressure, glucose tolerance, and plasma levels of high-density lipoprotein (HDL) cholesterol, triglycerides, incretins and markers of inflammation did not differ between the two groups.CONCLUSIONS:Daily consumption of 40 g of rose hip powder for 6 weeks can significantly reduce cardiovascular risk in obese people through lowering of systolic blood pressure and plasma cholesterol levels.European Journal of Clinical Nutrition advance online publication, 14 December 2011; doi:10.1038/ejcn.2011.203
    corecore