20 research outputs found

    Laparoscopic versus percutaneous cryotherapy for renal tumours: a systematic review and meta-analysis

    Get PDF
    Background: Cryoablation has emerged as an alternative to the more invasive partial nephrectomy for small renal masses. The approach can be carried out by two techniques, either laparoscopic cryoablation (LCA) or percutaneous cryoablation, (PCA) with CT guidance. We aimed to compare between the two procedures. Materials and Methods: A systematic review and meta-analysis was conducted, including studies comparing the two techniques. Outcomes included incomplete ablation, late local recurrence, cancer-specific survival, procedure time, transfusion rates, hospital stay, and complications. Results: A total of 1475 patients were included, 788 patients in the laparoscopic group and 687 patients in the percutaneous group. There was statistical difference favoring the laparoscopic group with regard to having less incomplete ablation (p = 0.0008) and higher cancer-specific survival patients (p = 0.04). However, there was longer hospital stays in the LCA group (p < 0.00001) and was found to be more costly than the PCA group. There was significantly more Clavien-I complications in the PCA group (p = 0.001) and more Clavien-III complications in the LCA group (p = 0.001). Otherwise, there were no differences in any other outcome parameter. Conclusion: LCA was found to have less incomplete tumor ablation rates and higher cancer-specific survival rates, however, higher hospitalization time, more major complications (Clavien III), and was costlier compared with PCA

    18F-FDG PET-CT Findings Before and After Laparoscopic Cryoablation of Small Renal Mass: An Initial Report

    Get PDF
    The aim of this study was to describe the characteristics of positron emission tomography (PET) molecular imaging combined with low-dose computed tomography (CT) in small renal mass (SRM) treated with cryoablation (CA). Currently, treatment success is defined by the absence of contrast enhancement at CT. However, the use of contrast is relatively contraindicated in patients with renal function impairment, mandating alternative follow-up strategies. Several reasons were identified as criteria for performing PET-CT before and/or after SRM-CA in 9 patients, and the results were retrospectively studied. The histology revealed renal cell carcinoma in 7 patients and oncocytoma in 2 patients. In 6 patients, a PET-CT was performed before and after CA. In one patient, the PET-CT was performed only before CA and in 2 patients only after CA. Before CA, clearly there was metabolic uptake of fluorine-18 fluorodeoxyglucose (18F-FDG) in the SRM in all patients. Following CA, the absence of 18F-FDG uptakes in the SRM could clearly be noticed. However, the tracer cannot always be distinguished from focal recurrence or reactive inflammatory tissue. In one patient, asymptomatic metastatic bone lesions were noticed when performing PET-CT at follow-up. This pilot study with 18F-FDG PET-CT for the follow-up of SRM cryosurgery showed that 18F-FDG PET-CT imaging could be used to characterize cryoablative tissue injury at different times after CA

    The PRO-RCC study:a long-term PROspective Renal Cell Carcinoma cohort in the Netherlands, providing an infrastructure for ‘Trial within Cohorts’ study designs

    Get PDF
    BACKGROUND: Ongoing research in the field of both localized, locally advanced and metastatic renal cell carcinoma has resulted in the availability of multiple treatment options. Hence, many questions are still unanswered and await further research. A nationwide collaborative registry allows to collect corresponding data. For this purpose, the Dutch PROspective Renal Cell Carcinoma cohort (PRO-RCC) has been founded, for the prospective collection of long-term clinical data, patient reported outcome measures (PROMs) and patient reported experience measures (PREMs).METHODS: PRO-RCC is designed as a multicenter cohort for all Dutch patients with renal cell carcinoma (RCC). Recruitment will start in the Netherlands in 2023. Importantly, participants may also consent to participation in a 'Trial within cohorts' studies (TwiCs). The TwiCs design provides a method to perform (randomized) interventional studies within the registry. The clinical data collection is embedded in the Netherlands Cancer Registry (NCR). Next to the standardly available data on RCC, additional clinical data will be collected. PROMS entail Health-Related Quality of Life (HRQoL), symptom monitoring with optional ecological momentary assessment (EMA) of pain and fatigue, and optional return to work- and/or nutrition questionnaires. PREMS entail satisfaction with care. Both PROMS and PREMS are collected through the PROFILES registry and are accessible for the patient and the treating physician.TRIAL REGISTRATION: Ethical board approval has been obtained (2021_218) and the study has been registered at ClinicalTrials.gov (NCT05326620).DISCUSSION: PRO-RCC is a nationwide long-term cohort for the collection of real-world clinical data, PROMS and PREMS. By facilitating an infrastructure for the collection of prospective data on RCC, PRO-RCC will contribute to observational research in a real-world study population and prove effectiveness in daily clinical practice. The infrastructure of this cohort also enables that interventional studies can be conducted with the TwiCs design, without the disadvantages of classic RCTs such as slow patient accrual and risk of dropping out after randomization.</p

    Renal cancer seeding metastases following retroperitoneoscopicassisted cryoablation: A case report

    No full text
    Nephron-sparing laparoscopy is the standard surgical treatment for clinical T1a renal tumours. However, the laparoscopic technique brings in its specific oncological safety concerns. Seeding metastases are reported: peritoneal metastases, port-tract metastases, and (sub-) cutaneous metastases. The method of laparoscopic assisted renal mass cryoablation is marked by the fact that traumatic tumour tissue handling is unavoidable. This case report reviews the rare occasion of seeding metastases in the retroperitoneal space following laparoscopic cryoablation of a small renal mass. The primary tumour showed no focal recurrence as reported by histological examination. The combination of two events as harming the integrity of cancer tissue and gas-circulation leading to the development of metastases in the retroperitoneal cavity is discussed. The combination of iatrogenic harming cancer tissue integrity and CO2-circulation leads to metastases in the retroperitoneal cavity. Therefore, we recommend performing image-guided renal mass biopsies before considering cryoablative surger

    18F-FDG PET-CT Findings Before and After Laparoscopic Cryoablation of Small Renal Mass: An Initial Report

    Get PDF
    The aim of this study was to describe the characteristics of positron emission tomography (PET) molecular imaging combined with low-dose computed tomography (CT) in small renal mass (SRM) treated with cryoablation (CA). Currently, treatment success is defined by the absence of contrast enhancement at CT. However, the use of contrast is relatively contraindicated in patients with renal function impairment, mandating alternative follow-up strategies. Several reasons were identified as criteria for performing PET-CT before and/or after SRM-CA in 9 patients, and the results were retrospectively studied. The histology revealed renal cell carcinoma in 7 patients and oncocytoma in 2 patients. In 6 patients, a PET-CT was performed before and after CA. In one patient, the PET-CT was performed only before CA and in 2 patients only after CA. Before CA, clearly there was metabolic uptake of fluorine-18 fluorodeoxyglucose ((18)F-FDG) in the SRM in all patients. Following CA, the absence of (18)F-FDG uptakes in the SRM could clearly be noticed. However, the tracer cannot always be distinguished from focal recurrence or reactive inflammatory tissue. In one patient, asymptomatic metastatic bone lesions were noticed when performing PET-CT at follow-up. This pilot study with (18)F-FDG PET-CT for the follow-up of SRM cryosurgery showed that (18)F-FDG PET-CT imaging could be used to characterize cryoablative tissue injury at different times after CA

    Ultrasonography of renal masses using contrast pulse sequence imaging: a pilot study

    No full text
    BACKGROUND AND PURPOSE: The use of contrast-enhanced ultrasonography for imaging of renal masses was first described in 1994. Since then, many new techniques for visualization of the effect of microbubble contrast agents have been developed. In this pilot study, a small number of patients was investigated with contrast pulse sequence imaging (CPS), and the characteristics of this perfusion imaging technique were evaluated subjectively and judged against the clinical diagnosis and histology findings when available. The purpose of this pilot study was to describe CPS imaging in several cases. PATIENTS AND METHODS: Eighteen patients with 20 previously identified renal masses were examined with CPS. Perfusion imaging was compared with clinical diagnosis and with histologic findings when available. RESULTS: Nineteen masses were visible. Various enhancement patterns could be observed, and interpretations of CPS characteristics are described. In carcinomas, inhomogeneous enhancement patterns were observed, and areas without enhancement inside the inhomogeneous lesions corresponded to necrotic areas in histologic specimens. All simple cysts and complex benign cysts showed absence of enhancement inside or in the wall of the lesion and a regular shape. CONCLUSION: To our knowledge, this is the first study in which the characteristics of CPS imaging of renal masses have been related to clinical diagnoses and histologic features. From the results of this pilot project, we conclude that CPS is a promising technique to determine perfusion patterns in the kidne

    Vascular fluorescence casting and imaging cryomicrotomy for computerized three-dimensional renal arterial reconstruction

    No full text
    OBJECTIVES To assess the combined use of a casting technique, cryomicrotomy imaging, and three-dimensional (3D) computer analysis as a method for visualizing and reconstructing the arterial vascular tree in a porcine renal model. MATERIAL AND METHODS The arterial branches of two porcine kidneys were filled with a fluorescent cast, after which they were cut into slices of 50 mu m in an imaging cryomicrotome. From each section, digital images of the cutting plane of the sample were taken and stored in the computer, after which stacks of images were rendered in 3D. RESULTS A 3D computerized reconstruction of the arterial vascular tree was constructed and showed the complete arterial anatomy up to arterioles of 50 mu m. CONCLUSION With visualization by fluorescence imaging cryomicrotomy, the anatomical and 3D reconstruction of the renal arterial blood supply in a pig kidney is possible up to a resolution of 50 mu

    The performance of 17-gauge cryoprobes in vitro

    No full text
    In cryosurgery it is crucial that the performance of cryoprobes is predictable and constant. In this study we tested the intra- and interneedle variation between 17-gauge cryoprobes in two homogeneous mediums. Also, a multiprobe setup was tested. Cryoprobe performance was defined as the time it takes one cryoprobe to lower the temperature from 0 to -20 degrees C as measured by four thermosensors each at 3 mm distance from the cryoprobe. In agar eight cryoprobes were tested during six freeze cycles, and in gel four cryoprobes during four freeze cycles; each freeze cycle in a different cup of agar or gel. Using more accurate 'bare' thermosensors three cryoprobes were tested in gel during two freeze cycles. A multiprobe configuration with four cryoprobes was tested during two freeze cycles in both agar and gel. Statistical analyses were done using ANOVA for repeated measures. There was no significant intraneedle variation, whereas both in agar and gel there was a significant interneedle variation (p <0.05). Mean performance in gel was better than in agar (p <0.001). Also, there was a significant variation between the four thermosensors (p <0.001). Using bare thermosensors mean performance was 2.7 times faster compared to measurements by regular thermosensors (p <0.001). In a multiprobe configuration, overall performance seems less variable and more reproducible compared to a single cryoprobe. In conclusion, the performance of cryoprobes differs depending on the medium and measuring device used. Cryoprobes deliver reproducible freeze cycles, although there is variation between different cryoprobes. In a multiprobe configuration performance seems less variabl

    Mentor-initiated approach in laparoscopic radical prostatectomy.

    No full text
    We evaluated the efficacy and safety of a mentor-initiated program for laparoscopic radical prostatectomy by analyzing its effect on the learning curve.Comparative StudyJournal ArticleSCOPUS: ar.jinfo:eu-repo/semantics/publishe
    corecore