6 research outputs found
Operating a full tungsten actively cooled tokamak: overview of WEST first phase of operation
WEST is an MA class superconducting, actively cooled, full tungsten (W) tokamak, designed to operate in long pulses up to 1000 s. In support of ITER operation and DEMO conceptual activities, key missions of WEST are: (i) qualification of high heat flux plasma-facing components in integrating both technological and physics aspects in relevant heat and particle exhaust conditions, particularly for the tungsten monoblocks foreseen in ITER divertor; (ii) integrated steady-state operation at high confinement, with a focus on power exhaust issues. During the phase 1 of operation (2017–2020), a set of actively cooled ITER-grade plasma facing unit prototypes was integrated into the inertially cooled W coated startup lower divertor. Up to 8.8 MW of RF power has been coupled to the plasma and divertor heat flux of up to 6 MW m−2 were reached. Long pulse operation was started, using the upper actively cooled divertor, with a discharge of about 1 min achieved. This paper gives an overview of the results achieved in phase 1. Perspectives for phase 2, operating with the full capability of the device with the complete ITER-grade actively cooled lower divertor, are also described
Status of severe accident studies at the end of the conceptual design of astrid feedback on mitigation features
International audienceThe ASTRID reactor developed by the CEA with its industrial partners, will be used for demonstration of the safety and operability, at the industrial scale, of sodium fast reactors of the 4th generation. Among the goals assigned to ASTRID, one is to improve the safety and the reliability of such reactor (compared to previous built sodium-cooled fast reactors). Regarding the innovations promoted in the ASTRID design, a low sodium void worth core concept (CFV core) has been developed. By means of various design provisions enhancing the neutron leakage in case of sodium draining, the overall sodium void effect of the ASTRID core is near zero and could even be negative. Additionally, mitigation devices should be implemented into the core in order to limit the calorific energy released in the fuel during the secondary phase of the severe accident. This paper deals with a synthesis of severe accident studies performed during the second period of the pre-conceptual design stage of the ASTRID project (2013-2015). The main insights of the studies in term of mitigation strategy and of mitigation device design are highlighted in the paper. The CFV core transient behavior has been investigated in case of generalized core melting situations initiated by postulated reactivity insertion ramps (UTOP) and unprotected loss of flow (ULOF). In case of UTOP transients, the mechanical energy released by molten fuel vapor expansion does not exceed several tenths of megajoule. Simulated ULOF transients do not lead to energetic power excursions thanks to the mitigation provisions and to the core design. Regarding ULOF transients, early boiling phase leads to core power decrease and the primary phase of the accident is not governed by a power excursion. The paper deals with the approach and the presentation of preliminary findings regarding mitigation provisions. Those provisions are investigated by considering a postulated core degraded state representative of the end of the transition phase. The possible scenario evolutions from this degraded state provide the following parameters mass and temperature of molten materials, mass and flow rates of materials relocated on the core catcher and possible ejected material mass above the core Those parameters are used for the determination of approximate loadings for the primary vessel and for the core catcher
Science and technology research and development in support to ITER and the Broader Approach at CEA
In parallel to the direct contribution to the procurement phase of ITER and Broader Approach, CEA has initiated research & development programmes, accompanied by experiments together with a significant modelling effort, aimed at ensuring robust operation, plasma performance, as well as mitigating the risks of the procurement phase. This overview reports the latest progress in both fusion science and technology including many areas, namely the mitigation of superconducting magnet quenches, disruption-generated runaway electrons, edge-localized modes (ELMs), the development of imaging surveillance, and heating and current drive systems for steady-state operation. The WEST (W Environment for Steady-state Tokamaks) project, turning Tore Supra into an actively cooled W-divertor platform open to the ITER partners and industries, is presented
Science and technology research and development in support to ITER and the Broader Approach at CEA
Équipe 107 : Physique des plasmas chaudsInternational audienceIn parallel to the direct contribution to the procurement phase of ITER and Broader Approach, CEA has initiated research & development programmes, accompanied by experiments together with a significant modelling effort, aimed at ensuring robust operation, plasma performance, as well as mitigating the risks of the procurement phase. This overview reports the latest progress in both fusion science and technology including many areas, namely the mitigation of superconducting magnet quenches, disruption-generated runaway electrons, edge-localized modes (ELMs), the development of imaging surveillance, and heating and current drive systems for steady-state operation. The WEST (W Environment for Steady-state Tokamaks) project, turning Tore Supra into an actively cooled W-divertor platform open to the ITER partners and industries, is presented
Operating a full tungsten actively cooled tokamak: overview of WEST first phase of operation
International audienceAbstract WEST is an MA class superconducting, actively cooled, full tungsten (W) tokamak, designed to operate in long pulses up to 1000 s. In support of ITER operation and DEMO conceptual activities, key missions of WEST are: (i) qualification of high heat flux plasma-facing components in integrating both technological and physics aspects in relevant heat and particle exhaust conditions, particularly for the tungsten monoblocks foreseen in ITER divertor; (ii) integrated steady-state operation at high confinement, with a focus on power exhaust issues. During the phase 1 of operation (2017–2020), a set of actively cooled ITER-grade plasma facing unit prototypes was integrated into the inertially cooled W coated startup lower divertor. Up to 8.8 MW of RF power has been coupled to the plasma and divertor heat flux of up to 6 MW m −2 were reached. Long pulse operation was started, using the upper actively cooled divertor, with a discharge of about 1 min achieved. This paper gives an overview of the results achieved in phase 1. Perspectives for phase 2, operating with the full capability of the device with the complete ITER-grade actively cooled lower divertor, are also described