26 research outputs found

    The Prevalence of Bacterial Infection in Patients Undergoing Elective ACDF for Degenerative Cervical Spine Conditions: A Prospective Cohort Study With Contaminant Control

    Get PDF
    Study Design: Prospective cohort study. Objectives: To determine the prevalence of bacterial infection, with the use of a contaminant control, in patients undergoing anterior cervical discectomy and fusion (ACDF). Methods: After institutional review board approval, patients undergoing elective ACDF were prospectively enrolled. Samples of the longus colli muscle and disc tissue were obtained. The tissue was then homogenized, gram stained, and cultured in both aerobic and anaerobic medium. Patients were classified into 4 groups depending on culture results. Demographic, preoperative, and postoperative factors were evaluated. Results: Ninety-six patients were enrolled, 41.7% were males with an average age of 54 ± 11 years and a body mass index of 29.7 ± 5.9 kg/m2. Seventeen patients (17.7%) were considered true positives, having a negative control and positive disc culture. Otherwise, no significant differences in culture positivity was found between groups of patients. However, our results show that patients were more likely to have both control and disc negative than being a true positive (odds ratio = 6.2, 95% confidence interval = 2.5-14.6). Propionibacterium acnes was the most commonly identified bacteria. Two patients with disc positive cultures returned to the operating room secondary to pseudarthrosis; however, age, body mass index, prior spine surgery or injection, postoperative infection, and reoperations were not associated with culture results. Conclusion: In our cohort, the prevalence of subclinical bacterial infection in patients undergoing ACDF was 17.7%. While our rates exclude patients with positive contaminant control, the possibility of contamination of disc cultures could not be entirely rejected. Overall, culture results did not have any influence on postoperative outcomes

    37th International Symposium on Intensive Care and Emergency Medicine (part 3 of 3)

    Full text link

    Enlarging premaxillary mass: A unique manifestation of extranodal diffuse B-cell lymphoma

    No full text
    Lymphomas are the most common nonepithelial malignancy in the head and neck region. Among these, non-Hodgkin Lymphoma (NHL) is the most prevalent, and diffuse large B-cell lymphoma (DLBCL) is the most common histologic subtype. NHL is known for its propensity for extranodal involvement, which can affect any anatomical location. The presence of perineural spread is frequently encountered in head and neck malignancies, including lymphomas. We report a case of a 40-year-old male with an enlarging infraorbital facial mass with associated erythema, pain, and paresthesia, which was subsequently found to be extranodal DLBCL with retrograde perineural spread along the infraorbital nerve

    Catastrophic acute failure of pelvic fixation in adult spinal deformity requiring revision surgery: a multicenter review of incidence, failure mechanisms, and risk factors

    No full text
    OBJECTIVE: There are few prior reports of acute pelvic instrumentation failure in spinal deformity surgery. The objective of this study was to determine if a previously identified mechanism and rate of pelvic fixation failure were present across multiple institutions, and to determine risk factors for these types of failures. METHODS: Thirteen academic medical centers performed a retrospective review of 18 months of consecutive adult spinal fusions extending 3 or more levels, which included new pelvic screws at the time of surgery. Acute pelvic fixation failure was defined as occurring within 6 months of the index surgery and requiring surgical revision. RESULTS: Failure occurred in 37 (5%) of 779 cases and consisted of either slippage of the rods or displacement of the set screws from the screw tulip head (17 cases), screw shaft fracture (9 cases), screw loosening (9 cases), and/or resultant kyphotic fracture of the sacrum (6 cases). Revision strategies involved new pelvic fixation and/or multiple rod constructs. Six patients (16%) who underwent revision with fewer than 4 rods to the pelvis sustained a second acute failure, but no secondary failures occurred when at least 4 rods were used. In the univariate analysis, the magnitude of surgical correction was higher in the failure cohort (higher preoperative T1-pelvic angle [T1PA], presence of a 3-column osteotomy; p \u3c 0.05). Uncorrected postoperative deformity increased failure risk (pelvic incidence-lumbar lordosis mismatch \u3e 10°, higher postoperative T1PA; p \u3c 0.05). Use of pelvic screws less than 8.5 mm in diameter also increased the likelihood of failure (p \u3c 0.05). In the multivariate analysis, a larger preoperative global deformity as measured by T1PA was associated with failure, male patients were more likely to experience failure than female patients, and there was a strong association with implant manufacturer (p \u3c 0.05). Anterior column support with an L5-S1 interbody fusion was protective against failure (p \u3c 0.05). CONCLUSIONS: Acute catastrophic failures involved large-magnitude surgical corrections and likely resulted from high mechanical strain on the pelvic instrumentation. Patients with large corrections may benefit from anterior structural support placed at the most caudal motion segment and multiple rods connecting to more than 2 pelvic fixation points. If failure occurs, salvage with a minimum of 4 rods and 4 pelvic fixation points can be successful
    corecore