1,536 research outputs found
The Photosynthetic Function of Manganese and Chloride
Author Institution: Charles F. Kettering Foundation, Yellow Springs, Ohi
Comparative Analysis of LASIK Flap Diameter and its Centration Using Two Different Femtosecond Lasers
The aim of this study was to compare the diameter, accuracy, variability, and centration with respect to the limbus of corneal flaps created by two femtosecond lasers, the VisuMax, and Wavelight FS200, for laser in situ keratomileusis (LASIK) and how these flaps affect visual outcomes. This is a retrospective chart review of flap morphology created during LASIK Surgery. Overall, 168 eyes underwent flap creation using the WaveLight FS200 laser, and on 189 eyes, the VisuMax laser was used. Of these total number, flap morphology was analyzed in a random sample of 158 eyes; 80 with the Visumax laser and 78 with the WaveLight FS200 laser. Intraoperative photos of the flaps taken by the Wavelight Allegretto EX500 were analyzed. Flap diameters and centration were measured using Adobe Acrobat Pro. All patients had visual acuity measurements including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent refraction (SE) and refractive astigmatism recorded three months postoperatively. Greater than 90% of patients in both groups achieved a UDVA of 20/20 postoperatively. The mean difference between targeted and achieved flap diameter was 0.50 +/- 0.15 mm in the VisuMax group and 0.35 +/- 0.15 millimeters (mm) in the FS200 group (P<0.01). The flap diameters of the VisuMax group were more precise with a variance of 0.024 mm compared to a variance of 0.038 mm in the FS200 group (P<0.05). VisuMax flaps were more nasally displaced (log(NA/TA) = -0.21 +/- 0.10 mm) compared to the FS200 flaps (log(NA/TA) = 0.03 +/- 0.10 mm), (P< 0.01). We concluded that both the VisuMax and FS200 created flaps larger than the preoperative targeted diameter. VisuMax created corneal flaps that had a greater degree of deviation from the targeted diameter when compared to flaps from the FS200. However, there was less variance in the VisuMax flap diameter. In addition, VisuMax flaps were more nasally displaced. There were no statistically significant differences in visual outcomes when comparing the two femtosecond lasers
Comparative Analysis of LASIK Flap Diameter and its Centration Using Two Different Femtosecond Lasers
The aim of this study was to compare the diameter, accuracy, variability, and centration with respect to the limbus of corneal flaps created by two femtosecond lasers, the VisuMax, and Wavelight FS200, for laser in situ keratomileusis (LASIK) and how these flaps affect visual outcomes. This is a retrospective chart review of flap morphology created during LASIK Surgery. Overall, 168 eyes underwent flap creation using the WaveLight FS200 laser, and on 189 eyes, the VisuMax laser was used. Of these total number, flap morphology was analyzed in a random sample of 158 eyes; 80 with the Visumax laser and 78 with the WaveLight FS200 laser. Intraoperative photos of the flaps taken by the Wavelight Allegretto EX500 were analyzed. Flap diameters and centration were measured using Adobe Acrobat Pro. All patients had visual acuity measurements including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent refraction (SE) and refractive astigmatism recorded three months postoperatively. Greater than 90% of patients in both groups achieved a UDVA of 20/20 postoperatively. The mean difference between targeted and achieved flap diameter was 0.50 +/- 0.15 mm in the VisuMax group and 0.35 +/- 0.15 millimeters (mm) in the FS200 group (P<0.01). The flap diameters of the VisuMax group were more precise with a variance of 0.024 mm compared to a variance of 0.038 mm in the FS200 group (P<0.05). VisuMax flaps were more nasally displaced (log(NA/TA) = -0.21 +/- 0.10 mm) compared to the FS200 flaps (log(NA/TA) = 0.03 +/- 0.10 mm), (P< 0.01). We concluded that both the VisuMax and FS200 created flaps larger than the preoperative targeted diameter. VisuMax created corneal flaps that had a greater degree of deviation from the targeted diameter when compared to flaps from the FS200. However, there was less variance in the VisuMax flap diameter. In addition, VisuMax flaps were more nasally displaced. There were no statistically significant differences in visual outcomes when comparing the two femtosecond lasers
Corneal Refractive Surgery in Patients with History of Optic Neuritis
Purpose The purpose of this study was to evaluate the risk of recurrence of optic neuritis after corneal refractive surgery in patients with a history of optic neuritis and to examine the safety and efficacy of the procedure in this population. Methods This was a retrospective chart review of patients with a history of optic neuritis who underwent laser-assisted in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) at a single tertiary center from June 1996 to December 2014. Fifteen eyes of 14 patients were included in this study. Visual acuity before and after the surgery was recorded. Patients were followed-up for over five years postoperatively for the recurrence of optic neuritis. Results The average LogMAR best corrected visual acuity (BCVA) preoperatively was 0.12 ± 0.19 (–0.10 to 0.60) and postoperatively was 0.06 ± 0.10 (–0.10 to 0.30). No eyes lost lines of BCVA. The average LogMAR uncorrected distance visual acuity (UDVA) after surgery was 0.12 ± 0.13 (0.00 to 0.48). Twenty-eight percent of patients reached a UDVA of 20/20 or better after refractive surgery. Optic neuritis recurred in 3/15 (20%) eyes and 3/14 patients (21%). Conclusion While corneal refractive procedures appear safe in patients with a history of optic neuritis, our data suggest that their efficacy may be reduced
Challenges of a Sustained Climate Observing System
Observations of planet Earth and especially all climate system components and forcings are increasingly needed for planning and informed decision making related to climate services in the broadest sense. Although significant progress has been made, much more remains to be done before a fully functional and dependable climate observing system exists. Observations are needed on spatial scales from local to global, and all time scales, especially to understand and document changes in extreme events. Climate change caused by human activities adds a new dimension and a vital imperative: to acquire climate observations of sufficient quality and coverage, and analyze them into products for multiple purposes to inform decisions for mitigation, adaptation, assessing vulnerability and impacts, possible geoengineering, and predicting climate variability and change and their consequences. A major challenge is to adequately deal with the continually changing observing system, especially from satellites and other remote sensing platforms such as in the ocean, in order to provide a continuous climate record. Even with new computational tools, challenges remain to provide adequate analysis, processing, meta-data, archival, access, and management of the resulting data and the data products. As volumes of data continue to grow, so do the challenges of distilling information to allow us to understand what is happening and why, and what the implications are for the future. The case is compelling that prompt coordinated international actions are essential to provide for information-based actions and decisions related to climate variability and change
Corneal Refractive Surgery in Patients with History of Optic Neuritis
Purpose: The purpose of this study was to evaluate the risk of recurrence of optic neuritis after corneal refractive surgery in patients with a history of optic neuritis and to examine the safety and efficacy of the procedure in this population.
Methods: This was a retrospective chart review of patients with a history of optic neuritis who underwent laser-assisted in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) at a single tertiary center from June 1996 to December 2014. Fifteen eyes of 14 patients were included in this study. Visual acuity before and after the surgery was recorded. Patients were followed-up for over five years postoperatively for the recurrence of optic neuritis.
Results: The average LogMAR best corrected visual acuity (BCVA) preoperatively was 0.12 ± 0.19 (–0.10 to 0.60) and postoperatively was 0.06 ± 0.10 (–0.10 to 0.30). No eyes lost lines of BCVA. The average LogMAR uncorrected distance visual acuity (UDVA) after surgery was 0.12 ± 0.13 (0.00 to 0.48). Twenty-eight percent of patients reached a UDVA of 20/20 or better after refractive surgery. Optic neuritis recurred in 3/15 (20%) eyes and 3/14 patients (21%).
Conclusion: While corneal refractive procedures appear safe in patients with a history of optic neuritis, our data suggest that their efficacy may be reduced
Astigmatic correction with implantation of a light adjustable vs monofocal lens: a single site analysis of a randomized controlled trial
AIM To evaluate the light adjustable lens (LAL) vs a standard monofocal lens in achieving target astigmatic refraction and improving postoperative uncorrected distance visual acuity (UDVA). METHODS This randomized controlled clinical trial included 40 patients with pre-existing astigmatism and visually significant cataract. Twenty-eight patients received the LAL and 12 control patients received a monofocal intraocular lens (IOL) after cataract extraction at a single institution. The patients with the LAL underwent adjustment by ultraviolet (UV) light postoperatively plus subsequent lock-in procedures and all patients returned to clinic for follow up of study parameters at 6, 9, and 12mo. Manifest refraction, distance visual acuity, and adverse events were recorded at each visit. RESULTS The mean cylinder before adjustment in eyes with the LAL was -0.89±0.58 D (-2.00 to 0.00 D) and -0.34±0.34 D (-1.25 to 0.00 D) after lock-in (P=1.68x10−8). The mean cylinder in patients with the monofocal lens was -1.00±0.32 D (-1.50 to -0.50 D) at 17-21d postoperatively, which was statistically different from the LAL cylinder post lock-in (P=1.43x10−6). UDVA in the LAL group was 20/20 or better in 79% of patients post lock-in with good stability over 12mo compared with 33% of the control patients with UDVA of 20/20 or better. CONCLUSION These results demonstrate that the LAL is more effective in achieving target refractions and improving postoperative UDVA in patients with pre-existing corneal astigmatism than a standard monofocal lens
Liposomal Bupivacaine Reduces Opioid Requirements Following Ravitch Repair of Pectus Excavatum
Presented as a poster at Indiana Society of Anesthesiologists Annual Meeting 2021
Slogging and Stumbling Toward Social Justice in a Private Elementary School: The Complicated Case of St. Malachy
This case study examines St. Malachy, an urban Catholic elementary school primarily serving children traditionally marginalized by race, class, linguistic heritage, and disability. As a private school, St. Malachy serves the public good by recruiting and retaining such traditionally marginalized students. As empirical studies involving Catholic schools frequently juxtapose them with public schools, the author presents this examination from a different tack. Neither vilifying nor glorifying Catholic schooling, this study critically examines the pursuit of social justice in this school context. Data gathered through a 1-year study show that formal and informal leaders in St. Malachy adapted their governance, aggressively sought community resources, and focused their professional development to build the capacity to serve their increasingly pluralistic student population. The analysis confirms the deepening realization that striving toward social justice is a messy, contradictory, and complicated pursuit, and that schools in both public and private sectors are allies in this pursuit
Wide-Field InfraRed Survey Telescope (WFIRST) Final Report
In December 2010, NASA created a Science Definition Team (SDT) for WFIRST,
the Wide Field Infra-Red Survey Telescope, recommended by the Astro 2010
Decadal Survey as the highest priority for a large space mission. The SDT was
chartered to work with the WFIRST Project Office at GSFC and the Program Office
at JPL to produce a Design Reference Mission (DRM) for WFIRST. Part of the
original charge was to produce an interim design reference mission by mid-2011.
That document was delivered to NASA and widely circulated within the
astronomical community. In late 2011 the Astrophysics Division augmented its
original charge, asking for two design reference missions. The first of these,
DRM1, was to be a finalized version of the interim DRM, reducing overall
mission costs where possible. The second of these, DRM2, was to identify and
eliminate capabilities that overlapped with those of NASA's James Webb Space
Telescope (henceforth JWST), ESA's Euclid mission, and the NSF's ground-based
Large Synoptic Survey Telescope (henceforth LSST), and again to reduce overall
mission cost, while staying faithful to NWNH. This report presents both DRM1
and DRM2.Comment: 102 pages, 57 figures, 17 table
- …