4 research outputs found
Human astrovirus infection associated with encephalitis in an immunocompetent child: a case report
Background
Until today, classic human astroviruses have not been associated with central nervous system infections in immunocompetent patients.
Case presentation
A 16-month-old Caucasian girl presented with repetitive generalized seizures with a 4-day history of watery diarrhea, which had already gradually improved. Initially, the prolonged seizures ceased after systemic midazolam treatment and were thought to be fever associated. However, her mental status remained altered, and after seizure recurrence, she was transferred to our pediatric intensive care unit. Seizure control was achieved by a combination of high-dose levetiracetam and phenobarbital, but she remained unconscious. An electroencephalogram at this time revealed generalized high voltage theta activity. All laboratory analyses, including extended blood and cerebrospinal fluid analyses, and a brain magnetic resonance imaging were normal.
On day 4, the child gradually became conscious, but was very agitated and not able to walk. Since an electroencephalogram at this time still revealed generalized high voltage theta activity, although she had not received sedative medications for 72 hours, she was diagnosed as having encephalopathy. At that time, results of diagnostic testing of the stool sample were positive for classic astrovirus infection, and we decided to analyze the initially obtained cerebrospinal fluid for astrovirus as well. Cerebrospinal fluid was also found positive for human astrovirus. Sequencing analysis revealed a classic astrovirus genotype 1 with exactly the same nucleotide sequence as in the feces. Clinically, the child gradually improved and was discharged on day 9.
Conclusions
Whereas the new human astrovirus subtypes have been recently associated with central nervous system infection, this is the first case of encephalitis in an immunocompetent child due to classic human astrovirus. Considering that classic human astroviruses are the third most common etiological agents of viral gastroenteritis in children, we believe that human astroviruses as causative agents for central nervous system infections should be considered more often, especially in children and infants with preceding gastroenteritis.Peer Reviewe
Evaluation of a microscale quantitative suspension test to determine the bactericidal and yeasticidal activity of glutaral – one step to improve sustainability in disinfectant testing
Aims: To evaluate a newly developed microscale quantitative suspension test compared to the existing standard suspension test using determination of the bactericidal and yeasticidal activity of glutaral as one step to improve the sustainability of disinfectant testing.Methods: The testing principles of the quantitative suspension test according to VAH method 9 (comparable to EN 13727) was used as a standard suspension test using 8.0 mL product test solution, 1.0 mL organic load and 1.0 mL test suspension. In addition, a micro-scale suspension test was performed in 96-well plates with 160 µL product test solution, 20 µL organic load and 20 µL test suspension. ATCC 6538, ATCC 15442 and ATCC 10231 were test organisms. Glutaral was tested at concentrations of 0.05%, 0.1%, 0.2% and 0.3% with exposure times of 1, 5 and 15 min. Polysorbate 80 (30 g/L), lecithin (9 g/L), L-histidine (1 g/L) and glycine (1/L) were used as validated neutralizers. After serial dilution of the disinfectant-neutralizer-mixture, plates were incubated for 48 h at 36°C (bacteria) or 72 hours at 30°C () and colony forming units (cfu) counted. The lg reduction was calculated as the difference between the results of the water control and the disinfectant at the end of the exposure time. All experiments were done in triplicate under clean conditions. Means of lg reduction were compared with the unpaired test, p<0.05 was considered to be significant.Results: Sufficient bactericidal activity according the VAH test requirements of at least 5 lg was found with both methods in 16 data sets of 24 data sets in total, and insufficient bactericidal activity of less than 5 lg was found with both methods in 7 data sets. In one data set, the mean lg reduction was above 5 lg with the microscale method and g with the VAH method, with no significant difference between the data sets (p=0.3096; 0.2% glutaral, 1 min, ). A sufficient yeasticidal activity of at least 4 lg was found with both methods in one data set, an insufficient yeasticidal activity of less than 4 lg was found with both methods in 8 data sets. With one exception, no significant differences were detected between the two methods below the efficacy threshold.Conclusions: The microscale quantitative suspension test proved to provide results similar to those of VAH method 9 when the bactericidal and yeasticidal activity of glutaralwas evaluated, with 32 out of 33 evaluations yielding consistent results in terms of efficacy. Its suitability should be confirmed with additional bacterial species, additional biocidal active substances and in other laboratories
Effect of Safety Measures on Bacterial Contamination Rates of Blood Components in Germany
Summary Requirements for bacterial testing of blood components on a defined quantity as part of routine quality control were in-troduced in Germany by the National Advisory Committee Blood of the German Federal Ministry of Health in 1997. The philosophy was to establish standardized methods for bac-terial testing. Numerous measures to reduce the risk of bac-terial contamination were implemented into the blood do-nation and manufacturing processes between 1999 and 2002. German Blood establishments performed culture-based bacterial testing on random samples of platelet con-centrates (PCs), red blood cells (RBCs) and fresh frozen plasma (FFP) and reported data out of the production peri-ods 1998, 2001 and 2005/2006. While the bacterial contami-nation rate of apheresis PCs remained nearly unchanged, i