42 research outputs found

    Low thalamic activity during a digit-symbol substitution task is associated with symptoms of subjective cognitive decline

    Get PDF
    IntroductionSubjective cognitive decline (SCD) may represent the earliest preclinical stage of Alzheimer's Disease (AD) for some older adults. However, the underlying neurobiology of SCD is not completely understood. Since executive function may be affected earlier than memory function in the progression of AD, we aimed to characterize SCD symptoms in terms of fMRI brain activity during the computerized digit-symbol substitution task (DSST), an executive function task. We also explored associations of DSST task performance with brain activation, SCD severity, and amyloid-ß (Aß) load.MethodsWe analyzed data from 63 cognitively normal older individuals (mean age 73.6 ± 7.2) with varying degree of SCD symptoms. Participants completed a computerized version of DSST in the MR scanner and a Pittsburgh Compound-B (PiB)-PET scan to measure global cerebral Aß load.ResultsA voxel-wise analysis revealed that greater SCD severity was associated with lower dorsomedial thalamus activation. While task performance was not associated with brain activation nor Aß load, slower reaction time was associated with greater SCD severity.DiscussionThe observed lower dorsomedial thalamus activation may reflect declining familiarity-based working memory and the trans-thalamic executive function pathway in SCD. SCD symptoms may reflect altered neural function and subtle decline of executive function, while Aß load may have an indirect impact on neural function and performance. Self-perceived cognitive decline may serve as a psychological/subjective marker reflecting subtle brain changes

    Post-mortem correlates of in vivo PiB-PET amyloid imaging in a typical case of Alzheimer's disease

    Get PDF
    The positron emission tomography (PET) radiotracer Pittsburgh Compound-B (PiB) binds with high affinity to β-pleated sheet aggregates of the amyloid-β (Aβ) peptide in vitro. The in vivo retention of PiB in brains of people with Alzheimer's disease shows a regional distribution that is very similar to distribution of Aβ deposits observed post-mortem. However, the basis for regional variations in PiB binding in vivo, and the extent to which it binds to different types of Aβ-containing plaques and tau-containing neurofibrillary tangles (NFT), has not been thoroughly investigated. The present study examined 28 clinically diagnosed and autopsy-confirmed Alzheimer's disease subjects, including one Alzheimer's disease subject who had undergone PiB-PET imaging 10 months prior to death, to evaluate region- and substrate-specific binding of the highly fluorescent PiB derivative 6-CN-PiB. These data were then correlated with region-matched Aβ plaque load and peptide levels, [3H]PiB binding in vitro, and in vivo PET retention levels. We found that in Alzheimer's disease brain tissue sections, the preponderance of 6-CN-PiB binding is in plaques immunoreactive to either Aβ42 or Aβ40, and to vascular Aβ deposits. 6-CN-PiB labelling was most robust in compact/cored plaques in the prefrontal and temporal cortices. While diffuse plaques, including those in caudate nucleus and presubiculum, were less prominently labelled, amorphous Aβ plaques in the cerebellum were not detectable with 6-CN-PiB. Only a small subset of NFT were 6-CN-PiB positive; these resembled extracellular ‘ghost’ NFT. In Alzheimer's disease brain tissue homogenates, there was a direct correlation between [3H]PiB binding and insoluble Aβ peptide levels. In the Alzheimer's disease subject who underwent PiB-PET prior to death, in vivo PiB retention levels correlated directly with region-matched post-mortem measures of [3H]PiB binding, insoluble Aβ peptide levels, 6-CN-PiB- and Aβ plaque load, but not with measures of NFT. These results demonstrate, in a typical Alzheimer's disease brain, that PiB binding is highly selective for insoluble (fibrillar) Aβ deposits, and not for neurofibrillary pathology. The strong direct correlation of in vivo PiB retention with region-matched quantitative analyses of Aβ plaques in the same subject supports the validity of PiB-PET imaging as a method for in vivo evaluation of Aβ plaque burden

    Validation of amyloid PET positivity thresholds in centiloids: a multisite PET study approach

    Full text link
    Abstract Background Inconsistent positivity thresholds, image analysis pipelines, and quantitative outcomes are key challenges of multisite studies using more than one β-amyloid (Aβ) radiotracer in positron emission tomography (PET). Variability related to these factors contributes to disagreement and lack of replicability in research and clinical trials. To address these problems and promote Aβ PET harmonization, we used [18F]florbetaben (FBB) and [18F]florbetapir (FBP) data from the Alzheimer’s Disease Neuroimaging Initiative (ADNI) to derive (1) standardized Centiloid (CL) transformations and (2) internally consistent positivity thresholds based on separate young control samples. Methods We analyzed Aβ PET data using a native-space, automated image processing pipeline that is used for PET quantification in many large, multisite AD studies and trials and made available to the research community. With this pipeline, we derived SUVR-to-CL transformations using the Global Alzheimer’s Association Interactive Network data; we used reference regions for cross-sectional (whole cerebellum) and longitudinal (subcortical white matter, brain stem, whole cerebellum) analyses. Finally, we developed a FBB positivity threshold using an independent young control sample (N=62) with methods parallel to our existing FBP positivity threshold and validated the FBB threshold using a data-driven approach in ADNI participants (N=295). Results The FBB threshold based on the young sample (1.08; 18 CL) was consistent with that of the data-driven approach (1.10; 21 CL), and the existing FBP threshold converted to CL with the derived transformation (1.11; 20 CL). The following equations can be used to convert whole cerebellum- (cross-sectional) and composite- (longitudinal) normalized FBB and FBP data quantified with the native-space pipeline to CL units: [18F]FBB: CLwhole cerebellum = 157.15 × SUVRFBB − 151.87; threshold=1.08, 18 CL [18F]FBP: CLwhole cerebellum = 188.22 × SUVRFBP − 189.16; threshold=1.11, 20 CL [18F]FBB: CLcomposite = 244.20 × SUVRFBB − 170.80 [18F]FBP: CLcomposite = 300.66 × SUVRFBP − 208.84 Conclusions FBB and FBP positivity thresholds derived from independent young control samples and quantified using an automated, native-space approach result in similar CL values. These findings are applicable to thousands of available and anticipated outcomes analyzed using this pipeline and shared with the scientific community. This work demonstrates the feasibility of harmonized PET acquisition and analysis in multisite PET studies and internal consistency of positivity thresholds in standardized units.http://deepblue.lib.umich.edu/bitstream/2027.42/173807/1/13195_2021_Article_836.pd

    Utility of 3'-[(18)F]fluoro-3'-deoxythymidine as a PET tracer to monitor response to gene therapy in a xenograft model of head and neck carcinoma.

    No full text
    Noninvasive imaging methodologies are needed to assess treatment responses to novel molecular targeting approaches for the treatment of squamous cell carcinoma of the head and neck (SCCHN). Computer tomography and magnetic resonance imaging do not effectively distinguish tumors from fibrotic tissue commonly associated with SCCHN tumors. Positron emission tomography (PET) offers functional non-invasive imaging of tumors. We determined the uptake of the PET tracers 2-deoxy-2-[(18)F]fluoro-D-glucose ([(18)F]FDG) and 3'-[(18)F]Fluoro-3'-deoxythymidine ([(18)F]FLT) in several SCCHN xenograft models. In addition, we evaluated the utility of [(18)F]FLT microPET imaging in monitoring treatment response to an EGFR antisense approach targeted therapy that has shown safety and efficacy in a phase I trial. Two of the 3 SCCHN xenograft models tested demonstrated no appreciable uptake or retention of [(18)F]FDG, but consistent accumulation of [(18)F]FLT. The third tumor xenograft SCCHN model (Cal33) demonstrated variable uptake of both tracers. SCCHN xenografts (1483) treated with EGFR antisense gene therapy decreased tumor volumes in 4/6 mice. Reduced uptake of [(18)F]FLT was observed in tumors that responded to epidermal growth factor antisense (EGFRAS) gene therapy compared to non-responding tumors or tumors treated with control sense plasmid DNA. These findings indicate that [(18)F]FLT PET imaging may be useful in monitoring SCCHN response to molecular targeted therapies, while [(18)F]FDG uptake in SCCHN xenografts may not be reflective of the level of metabolic activity characteristic of human SCCHN tumors

    Current use, training, and barriers in point-of-care ultrasound in hospital medicine: A national survey of VA hospitals

    No full text
    BACKGROUND: Point-of-care ultrasound (POCUS) can reduce procedural complications and improve the diagnostic accuracy of hospitalists. Currently, it is unknown how many practicing hospitalists use POCUS, which applications are used most often, and what barriers to POCUS use exist. OBJECTIVE: This study aimed to characterize current POCUS use, training needs, and barriers to use among hospital medicine groups (HMGs). DESIGN, SETTING, AND PARTICIPANTS: A prospective observational study of all Veterans Affairs (VA) medical centers was conducted between August 2019 and March 2020 using a web-based survey sent to all chiefs of HMGs. These data were compared to a similar survey conducted in 2015. RESULT: Chiefs from 117 HMGs were surveyed, with a 90% response rate. There was ongoing POCUS use in 64% of HMGs. From 2015 to 2020, procedural POCUS use decreased by 19%, but diagnostic POCUS use increased for cardiac (8%), pulmonary (7%), and abdominal (8%) applications. The most common barrier to POCUS use was lack of training (89%), and only 34% of HMGs had access to POCUS training. Access to ultrasound equipment was the least common barrier (57%). The proportion of HMGs with ≥1 ultrasound machine increased from 29% to 71% from 2015 to 2020. An average of 3.6 ultrasound devices per HMG was available, and 45% were handheld devices. CONCLUSION: From 2015 to 2020, diagnostic POCUS use increased, while procedural use decreased among hospitalists in the VA system. Lack of POCUS training is currently the most common barrier to POCUS use among hospitalists

    Ligand-based design of [18F]OXD-2314 for PET imaging in non-Alzheimer’s disease tauopathies

    No full text
    Abstract Positron emission tomography (PET) imaging of tau aggregation in Alzheimer’s disease (AD) is helping to map and quantify the in vivo progression of AD pathology. To date, no high-affinity tau-PET radiopharmaceutical has been optimized for imaging non-AD tauopathies. Here we show the properties of analogues of a first-in-class 4R-tau lead, [18F]OXD-2115, using ligand-based design. Over 150 analogues of OXD-2115 were synthesized and screened in post-mortem brain tissue for tau affinity against [3H]OXD-2115, and in silico models were used to predict brain uptake. [18F]OXD-2314 was identified as a selective, high-affinity non-AD tau PET radiotracer with favorable brain uptake, dosimetry, and radiometabolite profiles in rats and non-human primate and is being translated for first-in-human PET studies
    corecore