4 research outputs found

    Comparing Patch vs Pen Bolus Insulin Delivery in Type 2 Diabetes Using Continuous Glucose Monitoring Metrics and Profiles

    Get PDF
    OBJECTIVE: CeQur Simplicity™ (CeQur, Marlborough, MA) is a 3-day insulin delivery patch designed to meet mealtime insulin requirements. A recently reported 48-week, randomized, multicenter, interventional trial compared efficacy, safety and self-reported outcomes in 278 adults with type 2 diabetes (T2D) on basal insulin therapy who initiated and managed mealtime insulin therapy with a patch pump versus insulin pen. We assessed changes in key glycemic metrics among a subset of patients who wore a continuous glucose monitoring (CGM) device. METHODS: Study participants (patch, n = 49; pen, n = 48) wore a CGM device in masked setting during the baseline period and prior to week 24. Glycemic control was assessed using international consensus guidelines for percentage of Time In Range (%TIR: \u3e70% at 70-180 mg/dL), Time Below Range (%TBR: \u3c4% at \u3c70 mg/dL; \u3c1% at \u3c54 mg/dL), and Time Above Range (%TAR: \u3c25% at \u3e180 mg/dL; \u3c5% at \u3e250 mg/dL). RESULTS: Both the patch and pen groups achieved recommended targets in %TIR (74.1% ± 18.7%, 75.2 ± 16.1%, respectively) and marked reductions in %TAR \u3e180 mg/dL (21.1% ± 19.9%, 19.7% ± 17.5%, respectively) but with increased %TBR \u3c70 mg/dL (4.7% ± 5.2%, 5.1 ± 5.8, respectively), all P \u3c .0001. No significant between-group differences in glycemic improvements or adverse events were observed. CONCLUSIONS: CGM confirmed that the patch or pen can be used to safely initiate and optimize basal-bolus therapy using a simple insulin adjustment algorithm with SMBG. Preference data suggest that use of the patch vs pen may enhance treatment adherence

    Implementation of Basal-Bolus Therapy in Type 2 Diabetes:A Randomized Controlled Trial Comparing Bolus Insulin Delivery Using an Insulin Patch with an Insulin Pen

    Get PDF
    Background: Barriers to mealtime insulin include complexity, fear of injections, and lifestyle interference. This multicenter, randomized controlled trial evaluated efficacy, safety, and self-reported outcomes in adults with type 2 diabetes, inadequately controlled on basal insulin, initiating and managing mealtime insulin with a wearable patch versus an insulin pen. Methods: Adults with type 2 diabetes (n = 278, age: 59.2 +/- 8.9 years), were randomized to patch (n = 139) versus pen (n = 139) for 48 weeks, with crossover at week 44. Baseline insulin was divided 1:1 basal: bolus. Using a pattern-control logbook, subjects adjusted basal and bolus insulin weekly using fasting and premeal glucose targets. Results: Glycated hemoglobin (HbA1c) change (least squares mean +/- standard error) from baseline to week 24 (primary endpoint) improved (P \u3c 0.0001) in both arms, -1.7% +/- 0.1% and -1.6% +/- 0.1% for patch and pen (-18.6 +/- 1.1 and -17.5 +/- 1.1 mmol/mol), and was maintained at 44 weeks. The coefficient of variation of 7-point self-monitoring blood glucose decreased more (P = 0.02) from baseline to week 44 for patch versus pen. There were no differences in adverse events, including hypoglycemia (three severe episodes per arm), and changes in weight and insulin doses. Subject-reported treatment satisfaction, quality of life, experience ratings at week 24, and device preferences at week 48 significantly favored the patch. Most health care providers preferred patch for mealtime insulin. Conclusions: Bolus insulin delivered by patch and pen using an algorithm-based weekly insulin dose titration significantly improved HbA1c in adults with type 2 diabetes, with improved subject and health care provider experience and preference for the patch
    corecore