8 research outputs found

    Renal function impairment predicts mortality in patients with chronic heart failure treated with resynchronization therapy

    Get PDF
    Background: The use of cardiac resynchronization therapy (CRT) and implantable cardioverter- defibrillator (ICD) for advanced heart failure (HF) is increasing. Renal dysfunction is a common condition in HF which is associated with a worse survival. The study aims at identifying in patients with advanced HF treated with CRT the effect of baseline glomerular filtration rate (GFR), GFR improvement and left ventricular ejection fraction (LVEF) change, after 6-months of CRT implant, on survival. Methods: The study population consisted of 375 advanced HF patients who received a CRT between 1999 and 2009, of these 277 received also an ICD implant. Clinical characteristics (New York Heart Association [NYHA] functional class, ischemic vs. non-ischemic etiology, atrial fibrillation, diabetes, hypertension, LVEF, QRS duration and GFR were recorded. The use of common used drugs was evaluated. Cox proportional hazards analysis was calculated in order to evaluate variables associated to mortality. Results: During a median follow-up of 43.0 months, 93 (24.8%) patients died. Patients deceased during the study had at baseline higher NYHA class and lower LVEF and GFR. In Cox regression analysis, GFR predicts long-term mortality (hazard ratio [HR] 0.983; 95% confidence interval [CI] 0.969–0.998; p = 0.023) independently from the effect of others covariates. In addition, a positive GFR improvement 6 months after CRT implant is significantly associated with a lower hazard of mortality (for each 10 mL/min of GFR improvement HR 0.86; 95% CI 0.75–0.99; p = 0.038). Conclusions: GFR is a significant predictor of mortality in advanced HF patients who received CRT. A GFR improvement 6 months after CRT implant is significantly associated with a lower hazard of mortality.

    Solving the Riddle of Sudden Cardiac Death in Hypertrophic Cardiomyopathy: The Added Role of Cardiac Magnetic Resonance

    No full text
    Cardiac magnetic resonance (CMR) has been recently implemented in clinical practice to refine the daunting task of establishing the risk of sudden cardiac death (SCD) in patients with hypertrophic cardiomyopathy (HCM). We present an exemplificative case highlighting the practical clinical utility of this imaging modality in a 24-year-old man newly diagnosed with an apical HCM. CMR was essential in unmasking a high risk of SCD, which appeared low-intermediate after traditional risk assessment. A discussion examines the essential role of CMR in guiding the patient’s therapy and underlines the added value of CMR, including novel and potential CMR parameters, compared to traditional imaging assessment for SCD risk stratification

    Renal function impairment predicts mortality in patients with chronic heart failure treated with resynchronization therapy

    No full text
    BACKGROUND: The use of cardiac resynchronization therapy (CRT) and implantable cardioverter- defibrillator (ICD) for advanced heart failure (HF) is increasing. Renal dysfunction is a common condition in HF which is associated with a worse survival. The study aims at identifying in patients with advanced HF treated with CRT the effect of baseline glomerular filtration rate (GFR), GFR improvement and left ventricular ejection fraction (LVEF) change, after 6-months of CRT implant, on survival. METHODS: The study population consisted of 375 advanced HF patients who received a CRT between 1999 and 2009, of these 277 received also an ICD implant. Clinical characteristics (New York Heart Association [NYHA] functional class, ischemic vs. non-ischemic etiology, atrial fibrillation, diabetes, hypertension, LVEF, QRS duration and GFR were recorded. The use of common used drugs was evaluated. Cox proportional hazards analysis was calculated in order to evaluate variables associated to mortality. RESULTS: During a median follow-up of 43.0 months, 93 (24.8%) patients died. Patients deceased during the study had at baseline higher NYHA class and lower LVEF and GFR. In Cox regression analysis, GFR predicts long-term mortality (hazard ratio [HR] 0.983; 95% confidence interval [CI] 0.969-0.998; p = 0.023) independently from the effect of others covariates. In addition, a positive GFR improvement 6 months after CRT implant is significantly associated with a lower hazard of mortality (for each 10 mL/min of GFR improvement HR 0.86; 95% CI 0.75-0.99; p = 0.038). CONCLUSIONS: GFR is a significant predictor of mortality in advanced HF patients who received CRT. A GFR improvement 6 months after CRT implant is significantly associated with a lower hazard of mortality

    Bileaflet Tethering With Preserved LV Geometry and Function

    No full text
    An 81-year-old woman presented with acute pulmonary edema. Echocardiography revealed severe functional mitral regurgitation, the mechanism of which was unusual. An atypical bileaflet tethering caused by disharmonic annular remodeling, concomitant aortic dilatation, and reduced aorto-mitral angle without left ventricular dysfunction or dilatation was found. A transcatheter edge-to-edge repair was nonetheless successfully performed

    Stroke volume index and transvalvular flow rate trajectories in severe aortic stenosis treated with TAVR

    No full text
    Aims The prognostic impact of flow trajectories according to stroke volume index (SVi) and transvalvular flow rate (FR) in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) remains poorly assessed. We evaluated and compared SVi and FR prior and after TAVR for severe AS. Methods and results Patients were categorized according to SVi (<35 mL/m(2)) and FR (<200 mL/s). The association of pre- and post-TAVR SVi and FR with all-cause mortality up to 3 years was assessed with multivariable Cox regression models. Among 980 patients with pre-TAVR flow assessment, SVi was reduced in 41.3% and FR in 48.1%. Baseline flow status was not an independent mortality predictor [SVi: hazard ratio (HR) 1.22, 95% confidence interval (CI) 0.85-1.82, FR: HR 0.78, 95% CI 0.48-1.27]. Among 731 patients undergoing early (5 days, interquartile range 2-29) post-TAVR flow assessment, SVi recovered in 40.1% and FR in 49.0% patients with baseline low flow. Reduced FR following TAVR was an independent predictor of mortality (HR 1.67, 95% CI 1.02-2.74), whereas SVi was not (HR 0.97, 95% CI 0.53-1.78). Three-year estimated mortality in patients with recovered FR was lower than that in patients with reduced FR (13.3 vs. 37.7% vs, P = 0.003) and similar to that in patients with normal baseline FR (P = 0.317). Conclusion Baseline flow status was not an independent predictor of mid-term mortality among all-comers with severe AS undergoing TAVR. Flow recovery early after TAVR was frequent. Post-TAVR FR, but not SVi, was independently associated with mid-term all-cause mortality. By impacting flow status, AV replacement modifies the association of flow status with outcomes

    Stress Echocardiography in Italian Echocardiographic Laboratories: A Survey of the Italian Society of Echocardiography and Cardiovascular Imaging

    No full text
    Background: The Italian Society of Echography and Cardiovascular Imaging (SIECVI) conducted a national survey to understand the volumes of activity, modalities and stressors used during stress echocardiography (SE) in Italy. Methods: We analyzed echocardiography laboratory activities over a month (November 2022). Data were retrieved through an electronic survey based on a structured questionnaire, uploaded on the SIECVI website. Results: Data were obtained from 228 echocardiographic laboratories, and SE examinations were performed in 179 centers (80.6%): 87 centers (47.5%) were in the northern regions of Italy, 33 centers (18.4%) were in the central regions, and 61 (34.1%) in the southern regions. We annotated a total of 4057 SE. We divided the SE centers into three groups, according to the numbers of SE performed: &lt;10 SE (low-volume activity, 40 centers), between 10 and 39 SE (moderate volume activity, 102 centers) and &gt;= 40 SE (high volume activity, 37 centers). Dipyridamole was used in 139 centers (77.6%); exercise in 120 centers (67.0%); dobutamine in 153 centers (85.4%); pacing in 37 centers (21.1%); and adenosine in 7 centers (4.0%). We found a significant difference between the stressors used and volume of activity of the centers, with a progressive increase in the prevalence of number of stressors from low to high volume activity (P = 0.033). The traditional evaluation of regional wall motion of the left ventricle was performed in all centers, with combined assessment of coronary flow velocity reserve (CFVR) in 90 centers (50.3%): there was a significant difference in the centers with different volume of SE activity: the incidence of analysis of CFVR was significantly higher in high volume centers compared to low - moderate - volume (32.5%, 41.0% and 73.0%, respectively, P &lt; 0.001). The lung ultrasound (LUS) was assessed in 67 centers (37.4%). Furthermore for LUS, we found a significant difference in the centers with different volume of SE activity: significantly higher in high volume centers compared to low - moderate - volume (25.0%, 35.3% and 56.8%, respectively, P &lt; 0.001). Conclusions: This nationwide survey demonstrated that SE was significantly widespread and practiced throughout Italy. In addition to the traditional indication to coronary artery disease based on regional wall motion analysis, other indications are emerging with an increase in the use of LUS and CFVR, especially in high-volume centers
    corecore