4 research outputs found
SARS-CoV-2 Neutralizing Antibodies to B.1 and to BA.5 Variant after Booster Dose of BNT162b2 Vaccine in HIV Patients COVID-Naïve and on Successful Antiretroviral Therapy
: Live virus neutralization is the gold standard to investigate immunity. This prospective observational study aimed to determine the magnitude of response against the original B.1 lineage and against the BA.5 lineage six months after the third BNT162b2 mRNA vaccine dose in patients with HIV infection on successful antiretroviral treatment and no previous SARS-CoV-2 infection. A total of 100 subjects (M/F 83/17, median age 54 years) were included in the analysis: 95 had plasma HIV RNA <40 copies/mL, the median CD4+ T cell count at the administration of the third dose was 580 cells/mm3, and the median nadir CD4+ T cell count was 258 cells/mm3. Neutralizing antibodies (NtAb) against B.1 were detectable in all the subjects, but those to BA.5 were only detected in 88 (p < 0.001). The median NtAb titer to B.1 was significantly higher than that to BA.5 (393 vs. 60, p < 0.0001), and there was a strong positive correlation between the paired measurements (p < 0.0001). Linear regression on a subset of 87 patients excluding outlier NtAb titers showed that 48% of the changes in NtAb titers to BA.5 are related to the changes in value titers to B.1. SARS-CoV-2 variants evolve rapidly, challenging the efficacy of vaccines, and data on comparative NtAb responses may help in tailoring intervals between vaccine doses and in predicting vaccine efficacy
Humoral Response after Two Doses of BNT162b2 mRNA Vaccine Has a Role in Predicting Response after Three Doses That Is Related to Plasma HIV Viremia and Nadir CD4+ Cell Count in HIV-Positive Patients
We investigated the spike IgG levels of HIV+ patients on antiretroviral therapy six months after they received their second dose (T2) and six months after the third dose (T3) of the BNT162b2 mRNA vaccine, as well as the influence of different levels of plasma HIV viremia of overall CD4+ cell count and nadir value on the humoral time course. One hundred eighty-four patients were enrolled. The median age was 55 years, the median CD4+ cell count was 639 cells/mm3 and the median nadir value was 258 cells/mm3. On the basis of all tests performed during the study period, persistently undetectable plasma HIV RNA (PUD) was found in 66 patients, low-level viremia (LLV) in 57 and ongoing viremia (OV) in 61. Serum levels of IgG antibodies against a trimeric S-protein antigen were tested with DiaSorin Liaison SARS-CoV-2 TrimericS IgG and the response was classified as optimal (>75th percentile), intermediate (50th–25th percentile) and low (3 had 100% sensitivity in predicting a non-optimal response. In conclusion, we demonstrated the persistence of anti-spike IgG, with high serum levels occurring in most patients six months after the third dose of the BNT162b2 mRNA vaccine and a predictive role of humoral response at T2 in subjects with detectable plasma HIV viremia. Immunological alterations related to past immunodeficiency may persist despite immune reconstitution, and the nadir value could be a useful tool for elaborating personalized vaccine schedules
Organization and Activity of Italian Echocardiographic Laboratories: A Survey of the Italian Society of Echocardiography and Cardiovascular Imaging
Background: The Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI) conducted a national survey to understand better how different echocardiographic modalities are used and accessed in Italy. Methods: We analyzed echocardiography laboratory activities over a month (November 2022). Data were retrieved via an electronic survey based on a structured questionnaire, uploaded on the SIECVI website. Results: Data were obtained from 228 echocardiographic laboratories: 112 centers (49%) in the northern, 43 centers (19%) in the central, and 73 (32%) in the southern regions. During the month of observation, we collected 101,050 transthoracic echocardiography (TTE) examinations performed in all centers. As concern other modalities there were performed 5497 transesophageal echocardiography (TEE) examinations in 161/228 centers (71%); 4057 stress echocardiography (SE) examinations in 179/228 centers (79%); and examinations with ultrasound contrast agents (UCAs) in 151/228 centers (66%). We did not find significant regional variations between the different modalities. The usage of picture archiving and communication system (PACS) was significantly higher in the northern (84%) versus central (49%) and southern (45%) centers (P < 0.001). Lung ultrasound (LUS) was performed in 154 centers (66%), without difference between cardiology and noncardiology centers. The evaluation of left ventricular (LV) ejection fraction was evaluated mainly using the qualitative method in 223 centers (94%), occasionally with the Simpson method in 193 centers (85%), and with selective use of the three-dimensional (3D) method in only 23 centers (10%). 3D TTE was present in 137 centers (70%), and 3D TEE in all centers where TEE was done (71%). The assessment of LV diastolic function was done routinely in 80% of the centers. Right ventricular function was evaluated using tricuspid annular plane systolic excursion in all centers, using tricuspid valve annular systolic velocity by tissue Doppler imaging in 53% of the centers, and using fractional area change in 33% of the centers. When we divided into cardiology (179, 78%) and noncardiology (49, 22%) centers, we found significant differences in the SE (93% vs. 26%, P < 0.001), TEE (85% vs. 18%), UCA (67% vs. 43%, P < 0001), and STE (87% vs. 20%, P < 0.001). The incidence of LUS evaluation was similar between the cardiology and noncardiology centers (69% vs. 61%, P = NS). Conclusions: This nationwide survey demonstrated that digital infrastructures and advanced echocardiography modalities, such as 3D and STE, are widely available in Italy with a notable diffuse uptake of LUS in the core TTE examination, a suboptimal diffusion of PACS recording, and conservative use of UCA, 3D, and strain. There are significant differences between northern and central-southern regions and echocardiographic laboratories that pertain to the cardiac unit. This inhomogeneous distribution of technology represents one of the main issues that must be solved to standardize the practice of echocardiography
Stress Echocardiography in Italian Echocardiographic Laboratories: A Survey of the Italian Society of Echocardiography and Cardiovascular Imaging
Background: The Italian Society of Echography and Cardiovascular Imaging (SIECVI) conducted a national survey to understand the volumes of activity, modalities and stressors used during stress echocardiography (SE) in Italy. Methods: We analyzed echocardiography laboratory activities over a month (November 2022). Data were retrieved through an electronic survey based on a structured questionnaire, uploaded on the SIECVI website. Results: Data were obtained from 228 echocardiographic laboratories, and SE examinations were performed in 179 centers (80.6%): 87 centers (47.5%) were in the northern regions of Italy, 33 centers (18.4%) were in the central regions, and 61 (34.1%) in the southern regions. We annotated a total of 4057 SE. We divided the SE centers into three groups, according to the numbers of SE performed: <10 SE (low-volume activity, 40 centers), between 10 and 39 SE (moderate volume activity, 102 centers) and >= 40 SE (high volume activity, 37 centers). Dipyridamole was used in 139 centers (77.6%); exercise in 120 centers (67.0%); dobutamine in 153 centers (85.4%); pacing in 37 centers (21.1%); and adenosine in 7 centers (4.0%). We found a significant difference between the stressors used and volume of activity of the centers, with a progressive increase in the prevalence of number of stressors from low to high volume activity (P = 0.033). The traditional evaluation of regional wall motion of the left ventricle was performed in all centers, with combined assessment of coronary flow velocity reserve (CFVR) in 90 centers (50.3%): there was a significant difference in the centers with different volume of SE activity: the incidence of analysis of CFVR was significantly higher in high volume centers compared to low - moderate - volume (32.5%, 41.0% and 73.0%, respectively, P < 0.001). The lung ultrasound (LUS) was assessed in 67 centers (37.4%). Furthermore for LUS, we found a significant difference in the centers with different volume of SE activity: significantly higher in high volume centers compared to low - moderate - volume (25.0%, 35.3% and 56.8%, respectively, P < 0.001). Conclusions: This nationwide survey demonstrated that SE was significantly widespread and practiced throughout Italy. In addition to the traditional indication to coronary artery disease based on regional wall motion analysis, other indications are emerging with an increase in the use of LUS and CFVR, especially in high-volume centers