4 research outputs found

    A Pressure sensitive Mat for Measuring Contact pressure Distributions of Patients Lying on Hospital Beds

    Get PDF
    The authors describe a novel system for sensing and displaying the distribution of contact pressure caused by a patient\u27s lying on a hospital bed. The system includes a flexible, pressure sensitive mat, electronics to activate the mat, a small computer to process data, and a color video display. The present prototypes can sense pressure at 1,536 discrete locations in a rectangular grid of 24 x 64 nodes, each node representing an area of 4 cm2. The computer receives data from each node and displays the results as a false-color map, refreshable every 5 seconds. The pressure sensitive mat itself includes two orthogonal arrays of ribbon-like conductors, composed of silver coated nylon fabric, which are separated by insulating open cell foam rubber. The system monitors the electrical capacitance between selected pairs of horizontal and vertical conductors on opposite sides of the foam. The crossing points form pressure sensitive nodes. Increased contact pressure compresses the foam, thereby decreasing the distance between the conductors and increasing the capacitance. Node capacitance is determined by measuring the current through it from a voltage source. The outputs of the various nodes are scanned, normalized, and converted to pressures using the known compressive stressstrain relationship for the foam, and the data are then displayed as a false-color image of the pressure distribution

    Therapeutic indices for transchest defibrillator shocks: Effective, damaging, and lethal electrical doses

    Get PDF
    Although prospective studies of defibrillator shock overdose cannot be performed in man, the therapeutic indices of various defibrillating current waveforms can be measured in animals. We determined the ratios TD50/ED50 and LD50/ ED50 (where TD50 = median toxic or damageinducing dose, ED50 = median effective or defibrillating dose, and LD50 = median lethal dose) as measures of the therapeutic index for damped sine wave defibrillator shocks in dogs. Death of an animal and/or any degree of cardiac damage found by gross or microscopic examination were defined as harmful effects of shock, analogous to drug toxicity. In terms of peak current, the ED50, TD50, and LD50 were 1.1, 5.8, and 24 amperes/ kg; the therapeutic indices were TD50/ED50 = 5 for morphologic damage and LD50/ED50 = 22 for death. In terms of delivered energy the ED50, TD50, and LD50 were 1.5, 30, and 470 joules/kg; the therapeutic indices were TD50/ED50 = 20 for damage and LD50/ED50 = 320 for death. These data indicate a reasonable margin of safety for damped sine wave defibrillator shocks in dogs, and are consistent with reported incidences of suspected shockinduced damage in humans

    Insight into the Salivary Gland Transcriptome of Lygus lineolaris (Palisot de Beauvois)

    No full text
    corecore