224 research outputs found

    Arkansas Cotton Variety Test 1999

    Get PDF
    The primary aim of the Arkansas Cotton Variety Test is to provide unbiased data regarding the agronomic performance of cotton varieties in the major cotton growing areas in Arkansas. This information helps seed dealers establish marketing strategies and assists producers in choosing varieties to plant. In this way the annual test facilitates the inclusion of new, improved genetic material into Arkansas cotton production. The 1999 test had 67 entries (including 25 transgenic genotypes and 35 first-year entries), which were evaluated at sixsites in eastern Arkansas. The presence of four transgenic and five first-year entries among the top 10 yielding entries suggests that improvement is being accomplished in varietal development. This report also includes the Mississippi County Variety Test (an on-farm evaluation of selected varieties) and on-farm variety trials conducted by the Cooperative Extension Service

    Measurements of Young\u27s Modulus of Elasticity of the Canine Aorta with Ultrasound

    Get PDF
    We have developed an ultrasonic technique for determining the dynamic Young\u27s modulus of elasticity (E) of the canine aorta in vivo. Young\u27s modulus was measured in the descending thoracic aorta (DTA) and the abdominal aorta (AA) of 12 dogs over a range of mean blood pressures from 40-200 mmHg. The vessels were excised and dynamic moduli were determined in vitro postmortem from pressure-volume curves. The data so obtained were compared to the in vivo values. In vivo and in vitro moduli increased exponentially with mean distending pressure (P). The equation of best fit for these data was of the form E= E0 exp(aP). Constants E0 and a depended on the site of measurement (AA or DTA) and upon the particular animal. In vivo and in vitro moduli were not significantly different in the AA (AA: in vivo E0 = 667 ± 382 mmHg, a = 0.017 ± 0.004 mmHg-1; in vitro E0 = 888 ± 367, a= 0.016 ± 0.002). However, in vivo moduli exceeded in vitro moduli in the DTA. (DTA: in vivo E0 = 687 ± 241, a = 0.016 ± 0.004; in vitro E0 = 349 ± 64, a= 0.018 ± 0.003). The increased stiffness of the DTA compared to the AA in vivo may be due to the in situ tethering of the aorta to the spine by the parietal pleura

    Optimal Filling of Shapes

    Full text link
    We present filling as a type of spatial subdivision problem similar to covering and packing. Filling addresses the optimal placement of overlapping objects lying entirely inside an arbitrary shape so as to cover the most interior volume. In n-dimensional space, if the objects are polydisperse n-balls, we show that solutions correspond to sets of maximal n-balls. For polygons, we provide a heuristic for finding solutions of maximal discs. We consider the properties of ideal distributions of N discs as N approaches infinity. We note an analogy with energy landscapes.Comment: 5 page

    Efficacy and safety of the reciprocal pulse defibrillator current waveform

    Get PDF
    The efficacy and safety of a new defibrillating current waveform, consisting of a low-tilt 5 ms trapezoidal pulse followed closely by a second identical pulse of opposite polarity, was tested m seven isolated, perfused, working canine hearts suspended in an isoresistive, isosmotic shock bath at 37 oC. The efficacy and safety of the reciprocal pulse was compared with a single 5 ms pulse, a single 10 ms pulse, and a dual (unidirectional) 5 ms pulse waveform. The mean threshold average current densities for the 5 ms single pulse, 10 ms single pulse, dual 5 ms pulse, and reciprocal pulse (absolute values) were 50, 38, 36, and 37 mA/cm2, respectively. The corresponding mean threshold energy densities in the shock bath were 2.8, 2.9, 2.9, and 3.1 mJ/cm3. Despite the differences in threshold current density among the waveforms, no differences in safety factor (shock strength for 50 per cent post-shock depression, divided by threshold shock strength) were found among the waveforms. The current safety factors were 5.4, 5.4, 5.6, and 5.5 for the 5 ms single pulse, 10 ms single pulse, dual unidirectional pulse and reciprocal pulse, respectively. The corresponding energy density safety factors were 25, 27, 29, and 27. Thus the use of this reciprocal pulse waveform provides no advantage in efficacy or safety over waveforms of the same total duration

    Relationship between pulse-wave velocity and arterial elasticity

    Get PDF
    Pulse wave velocity (PWV) was measured in situ in 11 isolated canine common carotid arteries. Seven arteries exhibited a linear PWV vs. pressure function at pressures ranging from 0 to 200 mmHg. Four arteries yielded a linear relationship between PWV and pressure between 1 and 100 mmHg; for these vessels the relationship was nonlinear at higher pressures. Seven arteries (five from the group which was linear up to 200 mmHg and two from the group which was linear up to 100 mmHg) were excised and pressure/volume measurements were made in vivo. Using pressure/volume data, the Moens-Korteweg equation was evaluated as a predictor of the PWV vs. pressure relationship over the linear region. An expression was developed to enable prediction of the pressure/volume relationship using the coefficients at the linear PWV vs. pressure function, and these predictions were evaluated. We found that, for this range, the Moens-Korteweg equation provides a very good basis for predicting the increase in PWV with increasing bias pressure. In addition, we found that the pressure/volume relationship of common carotid arteries is well represented by an exponential of the form V/V0 = Keαf(P) , which was derived as the inverse solution to the Moens-Korteweg equation

    Attenuation and speed of 10 MHz ultrasound in canine blood of various packed cell volumes at 37C

    Get PDF
    The attenuation coefficient and the speed of 10 MHz ultrasound were determined in canine blood at 37 oC by a differential path length technique. Blood specimens with packed cell volumes (PCV) ranging from 0 to 53% were prepared by separating the cells from the plasma and mixing the two components. The mean attenuation coefficient increased linearly with packed cell volume, the least squares regression function being (dB/cm) = 0.992 +0.039 PCV with a standard error of the estimate = 0.255. The speed of 10 MHz ultrasound, c, in millimetres per second, increased with packed cell volume, the regression function for a wave equation model being 1/C2 = 0.418 +2.09 10-4 (PCV) 1.75 105 (PCV)2 with a standard error of the estimate = 0.0049 (mm/s)2. Both the attention coefficient and speed of 10 MHz ultrasound were greater in blood than in plasma to a degree dependent on the packed cell volume

    Dynamic Intraesophageal Imaging of the Heart with Ultrasound

    Get PDF
    Real-time images of the heart from within the esophagus are produced by a new intraesophageal ultrasonic sector scanner. Sixty images per second are displayed on a gray scale CRT in real-time and recorded on standard videotape for review. By interactive positioning of the esophageal probe, heart ventricles, atria, and valves can be visualized and their dynamics can be studied. The esophageal probe comprises four 5 MHz PZT-5 piezoelements of 6.35 mm diameter, mounted on a shaft that rotates at 900 rpm. The piezoelements are pulsed at a 5 kHz rate and the echoes are processed electronically

    Dynamic intraesophageal imagining of the heart with ultrasound

    Get PDF
    Real-time images of the heart from within the esophagus are produced by a new intraesophageal ultrasonic sector scanner. Sixty images per second are displayed on a gray scale CRT in real-time and recorded on standard videotape for review. By interactive positioning of the esophageal probe, heart ventricles, atria, and valves can be visualized and their dynamics can be studied. The esophageal probe comprises four 5 MHz PZT-5 piezoelements of 6.35 mm diameter, mounted on a shaft that rotates at 900 rpm. The piezoelements are pulsed at a 5 kHz rate and the echoes are processed electronically

    An animal model for testing automatic defibrillators

    Get PDF
    A promising therapy for ventricular fibrillation--a life-threatening cardiac arrhythmia--is the implantation of an automatic defibrillator. A critical component of such a device is the system that detects the presence of ventricular fibrillation. Automatic systems for detecting ventricular fibrillation have been tested with arrhythmias produced by electric shocks in normal canine hearts, but have not been tested with spontaneous arrhythmias in hyperirritable hearts. We have developed an animal model to create arrhythmias without electrical stimulation and have used it to test our automatic defibrillator. This model permits evaluation of both reliability to diagnose ventricular fibrillation and reliability to reject other tachyarrhythmias

    Arkansas Cotton Variety and Strain Tests 1998

    Get PDF
    The primary aim of the Arkansas Cotton Variety Test is to provide unbiased data regarding the agronomic performance of cotton varieties in the major cotton growing areas in Arkansas. This information helps seed dealers establish marketing strategies and assists producers in choosing varieties to plant. In this way the annual test facilitates the inclusion of new, improved genetic material into Arkansas cotton production. The 1998 test had 58 entries (including 19 transgenic genotypes and 21 first-year entries), which were evaluated at six sites in eastern Arkansas. The presence of four transgenic and five first-year entries among the top 10 yielding entries suggests that improvement is being accomplished in varietal development. This report also includes the Mississippi County Variety Test (an on-farm evaluation of selected varieties) and the Commercial Strain Test (a two-location evaluation of advanced breeding lines
    • …
    corecore