7 research outputs found
Lip print enhancement: review
Published online: 05 May 2020.Lip print (LP) evidence can be an essential tool for human forensics. LPs have conventionally been developed using substances such as lysochrome dyes, fluorescent dyes, indigo dye, aluminium powder, and silver metallic powder. However, techniques for LP enhancement from various substrates are currently inconsistent and lack standardisation in practice. This review summarises current knowledge on the physical and chemical techniques of LP enhancement, identifies limitations, and provides suggestions for future research on practical applications of cheiloscopy as a forensic tool in criminal justice.Maxwell Abedi, Constance Afoakwah and Dan Nana Osei Mensah Bons
Counterfeit formulations: analytical perspective on anorectics
Published online: 2 January 2021Purpose: This paper examines the scope of anorectics in counterfeit weight-reducing formulations and provides insight into the present state of research in determining such adulterants. Analytical techniques utilised in profiling adulterants found in slimming products, including limitations and mitigation steps of these conventional methods are also discussed. The current legal status of the anorectics and analogues routinely encountered in non-prescription slimming formulations is also explored. Methods: All reviewed literature was extracted from Scopus, Web of Science, PubMed, and Google Scholar databases using relevant search terms, such as, âcounterfeit drugsâ, âweight loss drugsâ, âweight-reducing drugsâ, âslimming drugsâ, âanorectic agentsâ, and âcounterfeit anorexicsâ. Legislation related to anorectics was obtained from the portals of various government and international agencies. Results: Anorectics frequently profiled in counterfeit slimming formulations are mostly amphetamine derivatives or its analogues. Five routinely reported pharmacological classes of adulterants, namely anxiolytics, diuretics, antidepressants, laxatives, and stimulants, are mainly utilised as coadjuvants in fake weigh-reducing formulations to increase bioavailability or to minimise anticipated side effects. Liquid and gas chromatography coupled with mass spectrometric detectors are predominantly used techniques for anorectic analysis due to the possibility of obtaining detailed information of adulterants. However, interference from the complex sample matrices of these fake products limits the accuracy of these methods and requires robust sample preparation methods for enhanced sensitivity and selectivity. The most common anorectics found in counterfeit slimming medicines are either completely banned or available by prescription only, in many countries. Conclusions: Slimming formulations doped with anorectic cocktails to boost their weight-reducing efficacy are not uncommon. Liquid chromatography combined with mass spectrometry remains the gold standard for counterfeit drug analysis, and requires improved preconcentration methods for rapid and quantitative identification of specific chemical constituents. Extensive method development and validation, targeted at refining existing techniques while developing new ones, is expected to improve the analytical profiling of counterfeit anorectics significantly.Dan Osei Mensah Bonsu, Constance Afoakwah, Maria de la Paz Aguilar-Caballo
Evaluation of the efficiency of Isohelix TM and Rayon swabs for recovery of DNA from metal surfaces
Published online: 12 November 2020Purpose We investigated the recovery and extraction efficiency of DNA from three metal surfaces (brass, copper, steel) relevant to forensic casework, and plastic (control) using two different swabbing systems; Rayon and Isohelix⢠swabs, with sterile water and isopropyl alcohol respectively, as the wetting solutions. Methods Twenty nanograms of human genomic DNA were applied directly to Isohelix⢠and Rayon swabs; and to the metal and plastic substrates. All substrates were left to dry for 24 h, followed by single wet swabbing and extraction with the DNA IQ⢠System. DNA extracts were quantified using real time quantitative PCR assays with SYBR green chemistry. Results DNA was extracted from directly seeded Isohelix⢠swabs with a high efficiency of 98%, indicating effective DNArelease from the swab into the extraction buffer. In contrast, only 58% of input DNA was recovered from seeded Rayon swabs, indicating higher DNA retention by these swabs. Isohelix⢠swabs recovered 32 â 53% of DNA from metal surfaces, whilst the Rayon swabs recovered 11â29%. DNA recovery was lowest from copper and highest from brass. Interestingly, Rayon swabs appeared to collect more DNA from the plastic surface than Isohelix⢠swabs, however, due to the lower release of DNA from Rayon swabs they returned less DNA overall following extraction than Isohelix⢠swabs. Conclusion These results demonstrate that DNA samples deposited on metal surfaces can be more efficiently recovered using Isohelix⢠swabs wetted with isopropyl alcohol than Rayon swabs wetted with sterile water, although recovery is affected by the substrate type.Dan O. M. Bonsu, Denice Higgins, Julianne Henry, Jeremy J. Austi
Ethics Reporting in Forensic Science Research Publications - A Review
An essential element of compliance with ethical standards in scientific research is the reporting of a verifiable declaration of ethical approval and, when human subjects are involved - informed consent, in published works. The level of reporting of ethical permission for research published in forensic and investigative sciences journals has not been explored to date. Hence, we examined the reporting of ethical approval and informed consent in original research utilising human or animal subjects published in six forensic science journals from 2010 to 2019. We identified 10,192 articles and retained 3010 that satisfied the inclusion criteria of utilising human (91.2%), or animal (7.0%) or both (1.8%) subjects or tissues in experiments. Just over a third (1079/3010) of all studies declared obtaining ethical approval, with 927 (85.9%) of those indicating the name of the ethical committee, but only 392 (36%) provided an approval code. Furthermore, while consent was said to have been sought in 527 (17.5%) of studies, only 155 of those reported that written informed consent was obtained, eleven stated oral (verbal) consent, while the remaining 357 studies (67.7%) did not report the process used to gain consent. Ethical approval reporting rates differed between different research types, availability of financial support and whether authors were affiliated to academia or industry. The results demonstrate a low level of declaration of ethical approval and informed consent in forensic science research and publication, requiring urgent rectification. We support the adoption of the model proposed by Forensic Science International: Genetics as baseline recommendations to facilitate consistent nomenclature, transparency, and standard of ethical reporting in forensic science.Dan O.M. Bonsua, Constance B. Afoakwah, Maxwell Abedi, Denice Higgins, Jeremy J. Austi
Spectroscopic (analytical) approach to gunshot residue analysis for shooting distance estimation: a systematic review
Published online: 16 November 2021Background: The determination of the shooting distance using gunshot residue (GSR) analysis is crucial in the investigation and reconstruction of firearm-related crimes. However, the conventional chemographic method for GSR analysis is destructive and has limited sensitivity and selectivity. While the spectroscopic method has potential in GSR analysis for crime investigation, there is a current lack of consistency in the spectroscopic results obtained for shooting distance estimation via GSR analysis. Addressing such limitations will enhance the forensic capabilities of law enforcement and provide an added advantage to crime laboratories during an investigation. It will also reinforce the use of such spectroscopic data in a criminal investigation. Main text: We obtained all peer-reviewed articles relevant to shooting distance estimation from searching Scopus, Web of Science, PubMed, and Google Scholar databases. We specifically searched the databases using the keywords âshooting distance,â ârange of fire,â âgunshot residue,â âfirearm discharge residue,â and âfirearm-related crimeâ and obtained 3811 records. We further filtered these records using a combination of two basic keywords âgunshot residueâ and âshooting distance estimationsâ yielding 108 papers. Following a careful evaluation of the titles, abstracts, and full texts, 40 original peer-reviewed articles on shooting distance estimation via GSR analysis were included in the study. The forgoing included additional sources (n = 5) we obtained from looking through the reference lists of the forensic articles we found. Short conclusion: This paper discusses the current scope of research concerning the chemographic and spectroscopic analysis of GSR for shooting distance estimation. It also examines the challenges of these techniques and provides recommendations for future research.Maxwell Abedi, Dan O. M. Bonsu, Isaac K. Badu, Richmond Afoakwah and Pooja Ahuj
Comparison of Isohelix (TM) and Rayon swabbing systems for touch DNA recovery from metal surfaces
Published online: 21 October 2021A previous study evaluating two swabbing systems found that DNA was best recovered from sterile metal substrates using an Isohelix⢠swab wetted with isopropyl alcohol rather than a Rayon swab with water as the wetting agent. We tested the same swabbing systems on metal (aluminum, brass, and stainless steel) and plastic substrates in a regularly touched environment to simulate the non-deliberate transfer of touch evidence likely seen in a casework scenario, to ascertain the performance of these swabs in an uncontrolled situation. Higher amounts of touch DNA were recovered with Isohelix⢠swabs (0.5 â 3.3 ng) compared to Rayon swabs (0.13 â 1.2 ng). The Isohelix⢠swabbing system was found to significantly recover more touch DNA (p = 0.04) from the metal substrates than the Rayon swabbing system, consistent with the findings of our previous work. The results contribute to our understanding of the impact of sample collection techniques on touch DNA recovery from problematic metal surfaces and suggest that supplemental cleaning of substrates as a precautionary step against the spread of infections may affect touch DNA persistence and the recovery efficiency of swabs.Dan O. M. Bonsu, Matthew Rodie, Denice Higgins, Julianne Henry, Jeremy J. Austi
Immunotherapy for acute myeloid leukemia (AML): a potent alternative therapy
The standard therapy of AML for many years has been chemotherapy with or without stem transplantation. However, there has not been any tangible improvement in this treatment beyond induction through chemotherapy and consolidation with allogeneic stem cell transplantation or chemotherapy. Residual AML cells which later cause relapse mostly persist even after rigorous standard therapy. It is imperative therefore to find an alternative therapy that can take care of the residual AML cells. With a better understanding of how the immune system works to destroy tumor cells and inhibit their growth, another therapeutic option immunotherapy has emerged to address the difficulties associated with the standard therapy. Identification of leukemia-associated antigens (LAA) and the fact that T and NK cells can be activated to exert cytotoxicity on AML cells have further introduced diverse immunotherapeutic development strategies. This review discusses the merits of current immunotherapeutic strategies such as the use of antibodies, adoptive T cells and alloreactive NK cell, and vaccination as against the standard therapy of AML.Desmond O. Acheampong, Christian K. Adokoh, Du-Bois Asante, Ernest A. Asiamah, Prince A. Barnie, Dan O.M. Bonsu, Foster Kye