2 research outputs found

    Establishment of Valid Laboratory Case Definition for Human Leptospirosis

    Get PDF
    Laboratory case definition of leptospirosis is scarcely de ned by a solid evaluation that determines cut-off values in the tests that are applied. This study describes the process of determining optimal cut-off titers of laboratory tests for leptospirosis for a valid case definition of leptospirosis. In this case the tests are the microscopic agglutination test (MAT) and an in-house IgM enzyme-linked immunosorbent assay (ELISA) both on single serum and paired samples using a positive culture as the reference test in the Dutch population. The specificity was assessed using panels of sera from healthy donors, cases with known other diseases and non-leptospirosis cases with symptoms compatible with leptospirosis. Cases were divided into three periods corroborating the acute phase (1-10 days post onset of illness (DPO)), the early convalescent (11-20 DPO) and the late convalescent phase (>20 DPO). Cut-off titers for MAT and IgM ELISA were determined as 1:160 and 1:80 respectively for all three periods. These cut-off titers combined 100% specificity with a sensitivity that changed according to the stage of disease for both tests. The low sensitivities in the early acute phase are consistent with the dynamics of the humoral immune response. IgM ELISA yielded higher sensitivities compared to MAT in the acute and early convalescent stages. Moreover, the optimal sensitivity of MAT, the gold standard was < 82%, implying that a significant part of global cases is missed by this recommended test. MAT and IgM ELISA manifested partly complementary, resulting in a higher sensitivity when combining the results of these two tests. The availability of paired samples and of adequate clinical and epidemiological data are other parameters that

    Prospective evaluation of three rapid diagnostic tests for diagnosis of human leptospirosis.

    Get PDF
    Diagnosis of leptospirosis by the microscopic agglutination test (MAT) or by culture is confined to specialized laboratories. Although ELISA techniques are more common, they still require laboratory facilities. Rapid Diagnostic Tests (RDTs) can be used for easy point-of-care diagnosis. This study aims to evaluate the diagnostic performance of the RDTs LeptoTek Dri Dot, LeptoTek Lateral Flow, and Leptocheck-WB, prospectively. During 2001 to 2012, one or two of the RDTs at the same time have been applied prior to routine diagnostics (MAT, ELISA and culture) on serum specimens from participants sent in for leptospirosis diagnosis. The case definition was based on MAT, ELISA and culture results. Participants not fulfilling the case definition were considered not to have leptospirosis. The diagnostic accuracy was determined based on the 1(st) submitted sample and paired samples, either in an overall analysis or stratified according to days post onset of illness. The overall sensitivity and specificity for the LeptoTek Dri Dot was 75% respectively 96%, for the LeptoTek Lateral Flow 78% respectively 95%, and for the Leptocheck-WB 78% respectively 98%. Based on the 1(st) submitted sample the sensitivity was low (51% for LeptoTek Dri Dot, 69% for LeptoTek Lateral Flow, and 55% for Leptocheck-WB), but substantially increased when the results of paired samples were combined, although accompanied by a lower specificity (82% respectively 91% for LeptoTek Dri Dot, 86% respectively 84% for LeptoTek Lateral Flow, and 80% respectively 93% for Leptocheck-WB). All three tests present antibody tests contributing to the diagnosis of leptospirosis, thus supporting clinical suspicion and contributing to awareness. Since the overall sensitivity of the tested RDTs did not exceed 80%, one should be cautious to rely only on an RDT result, and confirmation by reference tests is strongly recommended
    corecore