72 research outputs found

    Tumor Necrosis Factor-α Contributes to Ischemia- and Reperfusion-Induced Endothelial Activation in Isolated Hearts

    Get PDF
    During myocardial reperfusion, polymorphonuclear neutrophil (PMN) adhesion involving the intercellular adhesion molecule-1 (ICAM-1) may lead to aggravation and prolongation of reperfusion injury. We studied the role of early tumor necrosis factor-α (TNF-α) cleavage and nuclear factor-ÎșB (NF-ÎșB) activation on ICAM-1 expression and venular adhesion of PMN in isolated hearts after ischemia (15 minutes) and reperfusion (30 to 480 minutes). NF-ÎșB activation (electromobility shift assay) was found after 30 minutes of reperfusion and up to 240 minutes. ICAM-1 mRNA, assessed by Northern blot, increased during the same interval. Functional effect of newly synthesized adhesion molecules was found by quantification (in situ fluorescence microscopy) of PMN, given as bolus after ischemia, which became adherent to small coronary venules (10 to 50 mm in diameter). After 480 minutes of reperfusion, ICAM-1–dependent PMN adhesion increased 2.5-fold compared with PMN adhesion obtained during acute reperfusion. To study the influence of NF-ÎșB on PMN adhesion, we inhibited NF-ÎșB activation by transfection of NF-ÎșB decoy oligonucleotides into isolated hearts using HJV-liposomes. Decoy NF-ÎșB but not control oligonucleotides blocked ICAM-1 upregulation and inhibited the subacute increase in PMN adhesion. Similar effects were obtained using BB 1101 (10 ÎŒg), an inhibitor of TNF-α cleavage enzyme. These data suggest that ischemia and reperfusion in isolated hearts cause liberation of TNF-α, activation of NF-ÎșB, and upregulation of ICAM-1, an adhesion molecule involved in inflammatory response after ischemia and reperfusion

    Transcutaneous aortic valve replacement with the Edwards SAPIEN XT and Medtronic CoreValve prosthesis under fluoroscopic guidance and local anaesthesia only

    Get PDF
    Objective: To assess the feasibility of transcatheter aortic valve implantation (TAVI; Medtronic CoreValve and Edwards SAPIEN XT) under local anaesthesia with only mild analgesic medication and fluoroscopic guidance. Methods: 461 patients underwent TAVI under local anaesthesia with lidocaine. The procedure was performed successfully in 459 of the cases. All patients were also treated with piritramide, metoclopramide hydrochloride and 62 mg dimenhydrinate. Monitoring consisted of a six-electrode, virtual 12-lead ECG, pulse oximetry, and invasive arterial pressure measurement. There was no continuous surveillance by an anaesthesiologist. Results: There was no need for conversion to general anaesthesia except in four patients who required cardiopulmonary resuscitation. Conscious sedation with intravenous administration of midazolam for agitation or inotropic medication for prolonged hypotension was necessary in only seven of the 461 patients. The combined safety end point according to the Valve Academic Research Consortium consensus document was reached in 12.6%. Conclusions: Our results show that TAVI performed under local anaesthesia with only mild analgesic medication and under fluoroscopic guidance is feasible, with good outcome comparable to published data

    Direct stenting with the Bx VELOCITY balloon-expandable stent mounted on the Raptor rapid exchange delivery system versus predilatation in a European randomized Trial: the VELVET trial.

    Get PDF
    Abstract AIMS: This study examined the six-month angiographic results of direct coronary stenting, and compared the nine-month safety, efficacy and cost of this strategy versus stenting after balloon predilatation. METHODS: In phase I of VELVET, 122 patients (mean age = 62.3 +/- 10.1 years, 77% male, 11% with diabetes) with angina pectoris or myocardial ischemia resulting from a single de novo 51% to 95% coronary stenosis underwent direct stenting. The endpoints of phase I included angiographic findings and rates of major adverse cardiac events up to six months of follow-up. In phase II, 401 patients (mean age = 61.3 +/- 10.8 years, 79% male, 16% with diabetes) with angina pectoris or documented myocardial ischemia resulting from single or multiple, de novo or restenotic, coronary lesions were randomized between direc

    Treatment of aortic stenosis with a self-expanding transcatheter valve: the International Multi-centre ADVANCE Study

    Get PDF
    Aim Transcatheter aortic valve implantation has become an alternative to surgery in higher risk patients with symptomatic aortic stenosis. The aim of the ADVANCE study was to evaluate outcomes following implantation of a self-expanding transcatheter aortic valve system in a fully monitored, multi-centre ‘real-world' patient population in highly experienced centres. Methods and results Patients with severe aortic stenosis at a higher surgical risk in whom implantation of the CoreValve System was decided by the Heart Team were included. Endpoints were a composite of major adverse cardiovascular and cerebrovascular events (MACCE; all-cause mortality, myocardial infarction, stroke, or reintervention) and mortality at 30 days and 1 year. Endpoint-related events were independently adjudicated based on Valve Academic Research Consortium definitions. A total of 1015 patients [mean logistic EuroSCORE 19.4 ± 12.3% [median (Q1,Q3), 16.0% (10.3, 25.3%)], age 81 ± 6 years] were enrolled. Implantation of the CoreValve System led to a significant improvement in haemodynamics and an increase in the effective aortic valve orifice area. At 30 days, the MACCE rate was 8.0% (95% CI: 6.3-9.7%), all-cause mortality was 4.5% (3.2-5.8%), cardiovascular mortality was 3.4% (2.3-4.6%), and the rate of stroke was 3.0% (2.0-4.1%). The life-threatening or disabling bleeding rate was 4.0% (2.8-6.3%). The 12-month rates of MACCE, all-cause mortality, cardiovascular mortality, and stroke were 21.2% (18.4-24.1%), 17.9% (15.2-20.5%), 11.7% (9.4-14.1%), and 4.5% (2.9-6.1%), respectively. The 12-month rates of all-cause mortality were 11.1, 16.5, and 23.6% among patients with a logistic EuroSCORE ≀10%, EuroSCORE 10-20%, and EuroSCORE >20% (P< 0.05), respectively. Conclusion The ADVANCE study demonstrates the safety and effectiveness of the CoreValve System with low mortality and stroke rates in higher risk real-world patients with severe aortic stenosi

    Delayed intracardial shunting and hypoxemia after massive pulmonary embolism in a patient with a biventricular assist device

    Get PDF
    We describe the interdisciplinary management of a 34-year-old woman with dilated cardiomyopathy three months postpartum on a cardiac biventricular assist device (BVAD) as bridge to heart transplantation with delayed onset of intracardial shunting and subsequent hypoxemia due to massive pulmonary embolism. After emergency surgical embolectomy pulmonary function was highly compromised (PaO2/FiO2 54) requiring bifemoral veno-venous extracorporeal membrane oxygenation. Transesophageal echocardiography detected atrial level hypoxemic right-to-left shunting through a patent foramen ovale (PFO). Percutaneous closure of the PFO was achieved with a PFO occluder device. After placing the PFO occluder device oxygenation increased significantly (Δ paO2 119 Torr). The patient received heart transplantation 20 weeks after BVAD implantation and was discharged from ICU 3 weeks after transplantation

    Guided de-escalation of antiplatelet treatment in patients with acute coronary syndrome undergoing percutaneous coronary intervention (TROPICAL-ACS): a randomised, open-label, multicentre trial

    Full text link
    • 

    corecore