5 research outputs found

    Comparison of Hemoglobin A1c assay performance on two different commercial systems

    Get PDF
    Introduction: Glycated hemoglobin (HbA1c) is formed by non-enzymatic binding of glucose to the free amino group of the N-terminal end of the Ɵ-chain of hemoglobin A. HbA1c is representative of the mean blood glucose level over three months. The aim of the study was to evaluate the Hemoglobin A1c immunoturbidimetric assay performance on two different commercial systems.Methods: We evaluated the precision and trueness for determination of HbA1c in whole blood. Concentrations of total hemoglobin and HbA1c were evaluated on Dimension Xpand (Siemens) and Cobas 501 (Roche) analyzers. HbA1c was measured in a latex agglutination inhibition test. Commercial controls Liquichek Diabetes Control Level 1 and Liquichek Diabetes Control Level 2 (Bio Rad) at two levels were used for quality control. Analytical validation of HbA1c included: within-run imprecision, between-day imprecision, inaccuracy and comparison determination on the human samples on 2 systems: Dimension Xpand and Cobas 501 analyzers. Results: Within-run imprecision on the commercially controls for Level 1 is 4.5% and Level 2 is 3.2% between-day imprecision on commercially controls is 6.1% Level 1 and 5.1% Level 2 for respectively inac- curacy on commercially controls for Level 1 is 1.8% and Level 2 is 4.8%. Method comparison on human samples shows the correlation coefficient of 0.99.Conclusion: The presented results of the analytical evaluation methods for the determination of HbA1c showed an acceptable accuracy and precision

    Evaluation of tumor marker HE4 assay on the Elecsys 2010 analyzer

    Get PDF
    Introduction: Whey-acidic protein human epididymis protein 4 (HE4) is a new promising biomarker for epithelial ovarian cancer. The measured HE4 values may depend on the testing procedure used. The aim of this study was to evaluate the Methods: We evaluated a HE4 method on Elecsys 2010 analyzer. The method for quantitative determination of HE4 is direct, competitive chemiluminescent immunoassay. For quality control we use Elecsys PreciControl HE4 1 and 2. HE4 was measure on sera obtained from 56 women ( 20 healthy and 36 with epithelial ovarian cancer). Results: The Roche HE4 assays showed a good linearity (r=0.99) and precision (intrassayed total CV<5%). The median HE4 serum concentrations was significantly higher among EOC patients than healthy females (p<0,05). Elevated levels HE4 were found in 78 % patients with epithelial ovarian cancer. Conclusions: The presented results of the analytical evaluation methods for the determination of HE4 on the Elecsys 2010 analyzer showed an acceptable accuracy and precision

    Evaluation of tumor marker HE4 assay on the Elecsys 2010 analyzer

    No full text
    Introduction: Whey-acidic protein human epididymis protein 4 (HE4) is a new promising biomarker for epithelial ovarian cancer. The measured HE4 values may depend on the testing procedure used. The aim of this study was to evaluate the Methods: We evaluated a HE4 method on Elecsys 2010 analyzer. The method for quantitative determination of HE4 is direct, competitive chemiluminescent immunoassay. For quality control we use Elecsys PreciControl HE4 1 and 2. HE4 was measure on sera obtained from 56 women ( 20 healthy and 36 with epithelial ovarian cancer). Results: The Roche HE4 assays showed a good linearity (r=0.99) and precision (intrassayed total CV<5%). The median HE4 serum concentrations was significantly higher among EOC patients than healthy females (p<0,05). Elevated levels HE4 were found in 78 % patients with epithelial ovarian cancer. Conclusions: The presented results of the analytical evaluation methods for the determination of HE4 on the Elecsys 2010 analyzer showed an acceptable accuracy and precision

    Comparison of Hemoglobin A1c assay performance on two different commercial systems

    Get PDF
    Introduction: Glycated hemoglobin (HbA1c) is formed by non-enzymatic binding of glucose to the free amino group of the N-terminal end of the Ɵ-chain of hemoglobin A. HbA1c is representative of the mean blood glucose level over three months. The aim of the study was to evaluate the Hemoglobin A1c immunoturbidimetric assay performance on two different commercial systems. Methods: We evaluated the precision and trueness for determination of HbA1c in whole blood. Concentrations of total hemoglobin and HbA1c were evaluated on Dimension Xpand (Siemens) and Cobas 501 (Roche) analyzers. HbA1c was measured in a latex agglutination inhibition test. Commercial controls Liquichek Diabetes Control Level 1 and Liquichek Diabetes Control Level 2 (Bio Rad) at two levels were used for quality control. Analytical validation of HbA1c included: within-run imprecision, between-day imprecision, inaccuracy and comparison determination on the human samples on 2 systems: Dimension Xpand and Cobas 501 analyzers. Results: Within-run imprecision on the commercially controls for Level 1 is 4.5% and Level 2 is 3.2% between-day imprecision on commercially controls is 6.1% Level 1 and 5.1% Level 2 for respectively inac- curacy on commercially controls for Level 1 is 1.8% and Level 2 is 4.8%. Method comparison on human samples shows the correlation coefficient of 0.99. Conclusion: The presented results of the analytical evaluation methods for the determination of HbA1c showed an acceptable accuracy and precision

    Clinical aspects and importance of nutrition in homeostasis of the bone tissue

    Get PDF
    Substantial changes have occurred in the nutritional management of many diseases in the last twenty years. Introduction of standards, clinical review and implementation of evidence based practice led to re-evaluation of some established dietary interventions. The most common form of osteoporosis is the primary osteoporosis, which is the result of the bone loss and deterioration of bone structure, as people age. Bone loss and osteoporosis can be prevented through adequate nutrition, physical activity, and, if necessary, appropriate treatment. This review will focus on nutritional and clinical aspects of bone tissue homeostasis, with references to physiological and pathophysiological processes.Ā 
    corecore