20 research outputs found

    Trends in Pediatric Patient-Ventilator Asynchrony During Invasive Mechanical Ventilation

    Get PDF
    OBJECTIVES: To explore the level and time course of patient-ventilator asynchrony in mechanically ventilated children and the effects on duration of mechanical ventilation, PICU stay, and Comfort Behavior Score as indicator for patient comfort.DESIGN: Secondary analysis of physiology data from mechanically ventilated children.SETTING: Mixed medical-surgical tertiary PICU in a university hospital.PATIENTS: Mechanically ventilated children 0-18 years old were eligible for inclusion. Excluded were patients who were unable to initiate and maintain spontaneous breathing from any cause.MEASUREMENTS AND MAIN RESULTS: Twenty-nine patients were studied with a total duration of 109 days. Twenty-two study days (20%) were excluded because patients were on neuromuscular blockade or high-frequency oscillatory ventilation, yielding 87 days (80%) for analysis. Patient-ventilator asynchrony was detected through analysis of daily recorded ventilator airway pressure, flow, and volume versus time scalars. Approximately one of every three breaths was asynchronous. The percentage of asynchronous breaths significantly increased over time, with the highest prevalence on the day of extubation. There was no correlation with the Comfort Behavior score. The percentage of asynchronous breaths during the first 24 hours was inversely correlated with the duration of mechanical ventilation. Patients with severe patient-ventilator asynchrony (asynchrony index &gt; 10% or &gt; 75th percentile of the calculated asynchrony index) did not have a prolonged duration of ventilation.CONCLUSIONS: The level of patient-ventilator asynchrony increased over time was not related to patient discomfort and inversely related to the duration of mechanical ventilation.</p

    Additional work of breathing from trigger errors in mechanically ventilated children

    Get PDF
    BACKGROUND: Patient-ventilator asynchrony is associated with increased morbidity and mortality. A direct causative relationship between Patient-ventilator asynchrony and adverse clinical outcome have yet to be demonstrated. It is hypothesized that during trigger errors excessive pleural pressure swings are generated, contributing to increased work-of-breathing and self-inflicted lung injury. The objective of this study was to determine the additional work-of-breathing and pleural pressure swings caused by trigger errors in mechanically ventilated children. METHODS: Prospective observational study in a tertiary paediatric intensive care unit in an university hospital. Patients ventilated > 24 h and < 18 years old were studied. Patients underwent a 5-min recording of the ventilator flow-time, pressure-time and oesophageal pressure-time scalar. Pressure-time-product calculations were made as a proxy for work-of-breathing. Oesophageal pressure swings, as a surrogate for pleural pressure swings, during trigger errors were determined. RESULTS: Nine-hundred-and-fifty-nine trigger errors in 28 patients were identified. The additional work-of-breathing caused by trigger errors showed great variability among patients. The more asynchronous breaths were present the higher the work-of-breathing of these breaths. A higher spontaneous breath rate led to a lower amount of trigger errors. Patient-ventilator asynchrony was not associated with prolonged duration of mechanical ventilation or paediatric intensive care stay. CONCLUSIONS: The additional work-of-breathing caused by trigger errors in ventilated children can take up to 30-40% of the total work-of-breathing. Trigger errors were less common in patients breathing spontaneously and those able to generate higher pressure-time-product and pressure swings. TRIAL REGISTRATION: Not applicable

    The effect of pressure support on imposed work of breathing during paediatric extubation readiness testing

    Get PDF
    BACKGROUND: Paediatric critical care practitioners often make use of pressure support (PS) to overcome the perceived imposed work of breathing (WOBimp) during an extubation readiness test (ERT). However, no paediatric data are available that shows the necessity of adding of pressure support during such tests. We sought to measure the WOBimp during an ERT with and without added pressure support and to study its clinical correlate. This was a prospective study in spontaneously breathing ventilated children < 18 years undergoing ERT. Using tracheal manometry, WOBimp was calculated by integrating the difference between positive end-expiratory pressure (PEEP) and tracheal pressure (Ptrach) over the measured expiratory tidal volume (VTe) under two paired conditions: continuous positive airway pressure (CPAP) with and without PS. Patients with post-extubation upper airway obstruction were excluded. RESULTS: A total of 112 patients were studied. Median PS during the ERT was 10 cmH2O. WOBimp was significantly higher without PS (median 0.27, IQR 0.20-0.50 J/L) than with added PS (median 0.00, IQR 0.00-0.11 J/L). Although there were statistically significant changes in spontaneous breath rate [32 (23-42) vs. 37 (27-46) breaths/min, p < 0.001] and higher ET-CO2 [5.90 (5.38-6.65) vs. 6.23 (5.55-6.94) kPa, p < 0.001] and expiratory Vt decreased [7.72 (6.66-8.97) vs. 7.08 (5.82-8.08) mL/kg, p < 0.001] in the absence of PS, these changes appeared clinically irrelevant since the Comfort B score remained unaffected [12 (10-13) vs. 12 (10-13), P = 0.987]. Multivariable analysis showed that changes in WOBimp occurred independent of endotracheal tube size. CONCLUSIONS: Withholding PS during ERT does not lead to clinically relevant increases in WOBimp, irrespective of endotracheal tube size

    Driving Pressure Is Associated With Outcome in Pediatric Acute Respiratory Failure

    Get PDF
    OBJECTIVES: Driving pressure (ratio of tidal volume over respiratory system compliance) is associated with mortality in acute respiratory distress syndrome. We sought to evaluate if such association could be identified in critically ill children. DESIGN: We studied the association between driving pressure on day 1 of mechanical ventilation and ventilator-free days at day 28 through secondary analyses of prospectively collected physiology data. SETTING: Medical-surgical university hospital PICU. PATIENTS: Children younger than 18 years (stratified by Pediatric Mechanical Ventilation Consensus Conference clinical phenotype definitions) without evidence of spontaneous respiration. INTERVENTIONS: Inspiratory hold maneuvers. MEASUREMENTS AND MAIN RESULTS: Data of 222 patients with median age 11 months (2-51 mo) were analyzed. Sixty-five patients (29.3%) met Pediatric Mechanical Ventilation Consensus Conference criteria for restrictive and 78 patients (35.1%) for mixed lung disease, and 10.4% of all patients had acute respiratory distress syndrome. Driving pressure calculated by the ratio of tidal volume over respiratory system compliance for the whole cohort was 16 cm H2O (12-21 cm H2O) and correlated with the static airway pressure gradient (plateau pressure minus positive end-expiratory pressure) (Spearman correlation coefficient = 0.797; p < 0.001). Bland-Altman analysis showed that the dynamic pressure gradient (peak inspiratory pressure minus positive end-expiratory pressure) overestimated driving pressure (levels of agreement -2.295 to 7.268). Rematching the cohort through a double stratification procedure (obtaining subgroups of patients with matched mean levels for one variable but different mean levels for another ranking variable) showed a reduction in ventilator-free days at day 28 with increasing driving pressure in patients ventilated for a direct pulmonary indication. Competing risk regression analysis showed that increasing driving pressure remained independently associated with increased time to extubation (p < 0.001) after adjusting for Pediatric Risk of Mortality III 24-hour score, presence of direct pulmonary indication jury, and oxygenation index. CONCLUSIONS: Higher driving pressure was independently associated with increased time to extubation in mechanically ventilated children. Dynamic assessments of driving pressure should be cautiously interpreted

    Performance of acute respiratory distress syndrome definitions in a high acuity paediatric intensive care unit

    Get PDF
    BACKGROUND: For years, paediatric critical care practitioners used the adult American European Consensus Conference (AECC) and revised Berlin Definition (BD) for acute respiratory distress syndrome (ARDS) to study the epidemiology of paediatric ARDS (PARDS). In 2015, the paediatric specific definition, Paediatric Acute Lung Injury Consensus Conference (PALICC) was developed. The use of non-invasive metrics of oxygenation to stratify disease severity were introduced in this definition, although this potentially may lead to a confounding effect of disease severity since it is more common to place indwelling arterial lines in sicker patients. We tested the hypothesis that PALICC outperforms AECC/BD in our high acuity PICU, which employs a liberal use of indwelling arterial lines and high-frequency oscillatory ventilation (HFOV). METHODS: We retrospectively collected data from children < 18 years mechanically ventilated for at least 24 h in our tertiary care, university-affiliated paediatric intensive care unit. The primary endpoint was the difference in the number of PARDS cases between AECC/BD and PALICC. Secondary endpoints included mortality and ventilator free days. Performance was assessed by the area under the receiver operating characteristics curve (AUC-ROC). RESULTS: Data from 909 out of 2433 patients was eligible for analysis. AECC/BD identified 35 (1.4%) patients (mortality 25.7%), whereas PALICC identified 135 (5.5%) patients (mortality 14.1%). All but two patients meeting AECC/Berlin criteria were also identified by PALICC. Almost half of the cohort (45.2%) had mild, 33.3% moderate and 21.5% severe PALICC PARDS at onset. Highest mortality rates were seen in patients with AECC acute lung injury (ALI)/mild Berlin and severe PALICC PARDS. The AUC-ROC for Berlin was the highest 24 h (0.392 [0.124–0.659]) after onset. PALICC showed the highest AUC-ROC at the same moment however higher than Berlin (0.531 [0.345–0.716]). Mortality rates were significantly increased in patients with bilateral consolidations (9.3% unilateral vs 26.3% bilateral, p = 0.025). CONCLUSIONS: PALICC identified more new cases PARDS than the AECC/Berlin definition. However, both PALICC and Berlin performed poorly in terms of mortality risk stratification. The presence of bilateral consolidations was associated with a higher mortality rate. Our findings may be considered in future modifications of the PALICC criteria. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12931-021-01848-z

    Energy transmission in mechanically ventilated children:a translational study

    Get PDF
    Background: Recurrent delivery of tidal mechanical energy (ME) inflicts ventilator-induced lung injury (VILI) when stress and strain exceed the limits of tissue tolerance. Mechanical power (MP) is the mathematical description of the ME delivered to the respiratory system over time. It is unknown how ME relates to underlying lung pathology and outcome in mechanically ventilated children. We therefore tested the hypothesis that ME per breath with tidal volume (Vt) normalized to bodyweight correlates with underlying lung pathology and to study the effect of resistance on the ME dissipated to the lung. Methods: We analyzed routinely collected demographic, physiological, and laboratory data from deeply sedated and/or paralyzed children < 18 years with and without lung injury. Patients were stratified into respiratory system mechanic subgroups according to the Pediatric Mechanical Ventilation Consensus Conference (PEMVECC) definition. The association between MP, ME, lung pathology, and duration of mechanical ventilation as a primary outcome measure was analyzed adjusting for confounding variables and effect modifiers. The effect of endotracheal tube diameter (ETT) and airway resistance on energy dissipation to the lung was analyzed in a bench model with different lung compliance settings. Results: Data of 312 patients with a median age of 7.8 (1.7-44.2) months was analyzed. Age (p < 0.001), RR p < 0.001), and Vt < 0.001) were independently associated with MPrs. ME but not MP correlated significantly (p < 0.001) better with lung pathology. Competing risk regression analysis adjusting for PRISM III 24 h score and PEMVECC stratification showed that ME on day 1 or day 2 of MV but not MP was independently associated with the duration of mechanical ventilation. About 33% of all energy generated by the ventilator was transferred to the lung and highly dependent on lung compliance and airway resistance but not on endotracheal tube size (ETT) during pressure control (PC) ventilation. Conclusions: ME better related to underlying lung pathology and patient outcome than MP. The delivery of generated energy to the lung was not dependent on ETT size during PC ventilation. Further studies are needed to identify injurious MErs thresholds in ventilated children

    Transcutaneous electromyographic respiratory muscle recordings to quantify patient-ventilator interaction in mechanically ventilated children

    Get PDF
    BACKGROUND: To explore the feasibility of transcutaneous electromyographic respiratory muscle recordings to automatically quantify the synchronicity of patient-ventilator interaction in the pediatric intensive care unit. METHODS: Prospective observational study in a tertiary paediatric intensive care unit in an university hospital. Spontaneous breathing mechanically ventilated children < 18 years of age were eligible for inclusion. Patients underwent a 5-min continuous recording of ventilator pressure waveforms and transcutaneous electromyographic signal of the diaphragm. To evaluate patient-ventilator interaction, the obtained neural inspiration and ventilator pressurization timings were used to calculate trigger and cycle-off errors of each breath. Calculated errors were displayed in the dEMG-phase scale. RESULTS: Data of 23 patients were used for analysis. Based on the dEMG-phase scale, the median rates of synchronous, dyssynchronous and asynchronous breaths as classified by the automated analysis were 12.2% (1.9-33.8), 47.5% (36.3-63.1), and 28.9% (6.6-49.0). CONCLUSIONS: The dEMG-phase scale quantifying patient-ventilator breath synchronicity was demonstrated to be feasible and a reliable scale for mechanically ventilated children, reflected by high intra-class correlation coefficients. As this non-invasive tool is not restricted to a type of ventilator, it could easily be clinical implemented in the ventilated pediatric population. However; correlation studies between the EMG signal measured by surface EMG and esophageal catheters have to be performed
    corecore