9 research outputs found

    Long-term impact of the Vascular Study Group of New England carotid patch quality initiative.

    No full text
    OBJECTIVE: Patch angioplasty has been shown to decrease rates of restenosis after carotid endarterectomy (CEA). In 2003, the Vascular Study Group of New England (VSGNE) implemented its first quality initiative aimed at increasing the rates of patch closure after CEA. This study reports the effects of that initiative on the rate of patch closure in the VSGNE and also postoperative and 1-year CEA outcomes. METHODS: Patients undergoing CEA (N = 14,636) within the VSGNE between 2003 and 2014 were studied. Rates of in-hospital postoperative events (death, ipsilateral stroke or transient ischemic attack [TIA], and return to the operating room for bleeding) and events during 1 year of follow-up (stroke or TIA and restenosis \u3e70% or occlusion) were compared by repair type-patch closure, primary closure, or eversion. One-year follow-up events were also compared over time and by annualized surgeon volume. RESULTS: During the 12 years studied, patch use increased from 71% to 91% (P \u3c .001). There was no difference in postoperative death or ipsilateral stroke or TIA between the repair types. However, there was a statistically lower rate of return to the operating room for bleeding (P \u3c .001), 1-year stroke or TIA (P \u3c .003), and 1-year restenosis or occlusion (P \u3c .001) with patch closure. Overall, the rates of 1-year stroke or TIA and restenosis decreased over time in the VSGNE. The initiative affected patch closure rates and outcomes of high-volume surgeons (\u3e47 CEAs/y) the most. High-volume surgeons increased patch use from 50% to 90% and decreased their restenosis rates from 9.0% to 1.2% and 1-year stroke or TIA from 4.9% to 1.9% (P \u3c .001). CONCLUSIONS: The VSGNE carotid patch quality initiative successfully increased the rates of CEA patch closure. During the same time, there has been a decrease in postoperative bleeding requiring reoperation and 1-year ipsilateral neurologic events and restenosis or occlusion

    Outcomes of carotid endarterectomy in the Vascular Quality Initiative based on patch type.

    No full text
    OBJECTIVE: The Vascular Quality Initiative (VQI) is the largest registry of vascular surgical procedures and as such is capable of distinguishing small but important differences in outcomes. The goal of this study was to determine the outcomes of carotid endarterectomy (CEA) based on patch type, including bovine pericardium, autogenous vein, polytetrafluoroethylene (PTFE), and Dacron. METHODS: All primary CEAs performed with primary repair and patching (n = 70,987) within the VQI were retrospectively analyzed. Reoperative CEA and combined CEA and coronary artery bypass were excluded. Rates of any postoperative neurologic event, return to the operating room (bleeding, neurologic event, or wound complication), and restenosis (\u3e50% and \u3e80%) at 1-year follow-up were primary outcomes. Rates were compared by patch type using χ RESULTS: During the period of study, 2003 to 2017, there were 70,987 CEAs entered into the VQI registry. Bovine pericardium was the patch material with the highest frequency of use (n = 51,480), followed by Dacron (n = 12,356), vein (n = 1460), and PTFE (n = 1638). Bovine pericardium, vein, and Dacron had lower rates of postoperative neurologic events compared with PTFE or primary repair. Bovine pericardium had the lowest rate of restenosis at 1 year. By multivariate analysis, bovine pericardium (odds ratio [OR], 0.70; 95% confidence interval [CI], 0.56-0.89) and protamine use (OR, 0.74; 95% CI, 0.60-0.91) were associated with a lower incidence of return to the operating room. The use of Dacron, vein, and PTFE patches was not significantly different from the reference of primary closure. Multivariate analysis of postoperative neurologic events revealed that bovine pericardium (OR, 0.59; CI, 0.48-0.72) and Dacron (OR, 0.56; CI, 0.43-0.72) were associated with lower incidence of stroke or transient ischemic attack, whereas vein and PTFE were no different from primary closure. Bovine pericardium (OR, 0.57; CI, 0.44-0.75), Dacron (OR, 0.70; CI, 0.50-0.98), vein (OR, 0.72; CI, 0.53-0.98), and never smoking (OR, 0.87; CI, 0.78-0.96) were associated with a lower incidence of restenosis at 1 year by multivariate analysis. CONCLUSIONS: Bovine pericardium has superior outcomes both postoperatively and at 1 year compared with other patch materials. The large volume of patient data contained in the VQI makes it possible to compare outcomes that have small but meaningful differences

    Understanding the Effect of Bias on the Experience of Women Surgeons: A Qualitative Study

    No full text
    BACKGROUND: Exploring the lived experiences of surgeons is necessary to understand the changing culture of surgery and the unique challenges of being a woman in surgery. Surgeons have significant experiences and observations best discovered through qualitative study. The purpose of this study is to identify the similarities and differences between the experiences of men and women surgeons after initiation of mandatory microaggression training. STUDY DESIGN: Qualitative semi-structured interviews with female and male surgeons and residents were done following a year-long series of training sessions on the detrimental effects of microaggression. Participants were selected using a convenience sampling method. MAXQDA coding software (Verbi) was used to evaluate interview transcripts with thematic analysis. RESULTS: Nineteen surgeons and surgical residents were interviewed. The participants were of equal gender identification, with the majority being attending surgeons. Multiple themes highlighted similarities and differences between male and female participants. Differences were noted in identification of a sensitive personality, family planning considerations, and experiences of bias. Similarities were related to the personality traits required to be successful in surgery, the sacrifice inherent to a surgical career, and the war rhetoric used to describe the comradery of residency. CONCLUSION: The challenges and rewards of surgery are similar for women and men, but women have additional stressors, including gender-based bias, microaggression, and family planning. These stressors take up energy, decreasing the mental space available for additional roles and affecting the work environment. Microaggression education can incite necessary discussions of bias and provide women with an opportunity to reflect on and share their experiences

    Outcomes of carotid endarterectomy in the Vascular Quality Initiative based on patch type.

    No full text
    OBJECTIVE: The Vascular Quality Initiative (VQI) is the largest registry of vascular surgical procedures and as such is capable of distinguishing small but important differences in outcomes. The goal of this study was to determine the outcomes of carotid endarterectomy (CEA) based on patch type, including bovine pericardium, autogenous vein, polytetrafluoroethylene (PTFE), and Dacron. METHODS: All primary CEAs performed with primary repair and patching (n = 70,987) within the VQI were retrospectively analyzed. Reoperative CEA and combined CEA and coronary artery bypass were excluded. Rates of any postoperative neurologic event, return to the operating room (bleeding, neurologic event, or wound complication), and restenosis (\u3e50% and \u3e80%) at 1-year follow-up were primary outcomes. Rates were compared by patch type using χ RESULTS: During the period of study, 2003 to 2017, there were 70,987 CEAs entered into the VQI registry. Bovine pericardium was the patch material with the highest frequency of use (n = 51,480), followed by Dacron (n = 12,356), vein (n = 1460), and PTFE (n = 1638). Bovine pericardium, vein, and Dacron had lower rates of postoperative neurologic events compared with PTFE or primary repair. Bovine pericardium had the lowest rate of restenosis at 1 year. By multivariate analysis, bovine pericardium (odds ratio [OR], 0.70; 95% confidence interval [CI], 0.56-0.89) and protamine use (OR, 0.74; 95% CI, 0.60-0.91) were associated with a lower incidence of return to the operating room. The use of Dacron, vein, and PTFE patches was not significantly different from the reference of primary closure. Multivariate analysis of postoperative neurologic events revealed that bovine pericardium (OR, 0.59; CI, 0.48-0.72) and Dacron (OR, 0.56; CI, 0.43-0.72) were associated with lower incidence of stroke or transient ischemic attack, whereas vein and PTFE were no different from primary closure. Bovine pericardium (OR, 0.57; CI, 0.44-0.75), Dacron (OR, 0.70; CI, 0.50-0.98), vein (OR, 0.72; CI, 0.53-0.98), and never smoking (OR, 0.87; CI, 0.78-0.96) were associated with a lower incidence of restenosis at 1 year by multivariate analysis. CONCLUSIONS: Bovine pericardium has superior outcomes both postoperatively and at 1 year compared with other patch materials. The large volume of patient data contained in the VQI makes it possible to compare outcomes that have small but meaningful differences

    Patients with end-stage renal disease have poor outcomes after endovascular abdominal aortic aneurysm repair.

    No full text
    OBJECTIVE: Although endovascular repair of abdominal aortic aneurysms (AAAs) has been demonstrated to have favorable outcomes, not all cohorts of patients with AAA fare equally well. Our goal was to investigate perioperative and 1-year outcomes in patients with end-stage renal disease (ESRD) on dialysis, who have traditionally fared worse after vascular interventions, to assess how ESRD affects outcomes in a large modern cohort of endovascular aneurysm repair (EVAR) patients. METHODS: The Vascular Quality Initiative database was queried for all patients undergoing EVAR from 2010 to 2017. ESRD patients were compared with patients not on dialysis. Propensity-matched scoring and multivariable analysis were used to isolate the effects of ESRD. RESULTS: Of 28,683 EVARs identified, there were 321 (1.12%) patients with ESRD on dialysis. Patients with ESRD had no difference in presenting AAA size (57.5 ± 12.7 mm vs 56.7 ± 17.2 mm; P = .44); however, they had more urgent/emergent repairs (20.6% vs 13.6%; P = .002) than those without ESRD. ESRD patients were more often younger, nonwhite, and nonobese and less likely to have commercial insurance (P \u3c .05). ESRD patients more often had hypertension, coronary artery disease, congestive heart failure, previous lower extremity bypass, aneurysm repair, and carotid interventions (P \u3c .05). There was no difference in the rate of concomitant procedures. Matching based on demographics, comorbidities, and operative details showed that ESRD patients had longer hospital length of stay (4.8 ± 9.4 days vs 4.1 ± 12.6 days; P = .026) and higher 30-day mortality (7% vs 2.4%; P \u3c .001). There was no difference in cardiac, pulmonary, lower extremity, bowel, and stroke complications or return to the operating room. On multivariable analysis, ESRD was associated with 30-day mortality (odds ratio, 4.1; 95% confidence interval, 2.6-6.7; P \u3c .001). Of the 24,750 elective EVARs, 1.04% had ESRD on dialysis. Matched data for elective EVAR show increased postoperative length of stay, hospital mortality, and 30-day mortality for ESRD patients on dialysis compared with those who are not. There was no association with postoperative myocardial infarction or pulmonary complications. At 1 year, patients with ESRD on dialysis had worse survival (78% vs 94%; P \u3c .001), and ESRD was associated with higher mortality (hazard ratio, 3.3; 95% confidence interval, 2.5-4.2; P \u3c .001). CONCLUSIONS: Among patients undergoing EVAR, ESRD is independently associated with higher perioperative and 1-year mortality despite not being associated with higher postoperative complications. This should be taken into account during informed consent for EVAR and risk-benefit considerations in this high-risk population, particularly for elective repair

    Comparison of major adverse event rates after elective endovascular aneurysm repair in New England using a novel measure of complication severity.

    No full text
    OBJECTIVE: Major adverse event (MAE) rates are used as an outcome measure after surgical procedures. Although MAE rates summarize the occurrences of adverse events, they do not reflect differences in severity of these events. We propose that a measure of complication severity could provide a more accurate assessment about the quality of care. We aimed to analyze and to describe the regional variation in elective endovascular aneurysm repair (EVAR) MAE rates across centers in the Vascular Study Group of New England and to create an index for describing complication severity. METHODS: Patients undergoing elective EVAR (n = 4731) at 30 Vascular Study Group of New England centers between 2003 and 2016 were studied. The MAE composite end point was defined as the occurrence of any of the following postoperative events: myocardial infarction, dysrhythmia, congestive heart failure, leg ischemia, renal insufficiency, bowel complication, reoperation, surgical site infection, stroke, respiratory complication, and no home discharge. An adjustment factor (complication severity index) was calculated as a ratio of length of stay for complicated to uncomplicated cases. Multivariate logistic regression was used to calculate predicted MAE rates. The observed and predicted MAE rates as well as complication severity index rates were compared among centers and across quintiles of center volume. RESULTS: Observed MAE rates varied widely, ranging from 0% to 39%. Multivariate predictors of MAE included abdominal aortic aneurysm diameter \u3e6 cm (odds ratio [OR], 2.1; 95% confidence interval [CI], 2.0-2.3), female sex (OR, 2.0; 95% CI, 1.8-2.2), chronic renal insufficiency (OR, 1.9; 95% CI, 1.7-2.1), age \u3e75 years (OR, 1.9; 95% CI, 1.8-2.1), congestive heart failure (OR, 1.7; 95% CI, 1.5-1.9), chronic obstructive pulmonary disease (OR, 1.5; 95% CI, 1.4-1.6), diabetes (OR, 1.4; 95% CI, 1.1-1.7), positive stress test result (OR, 1.2; 95% CI, 1.1-1.4), preoperative beta blocker (OR, 1.2; 95% CI, 1.1-1.3), and no preoperative statin (OR, 1.2; 95% CI, 1.1-1.3). Predicted MAE rates had little variation (range, 21%-29%). In comparing observed MAE rates and complication severity, there was an inverse relation between the two, suggesting that although certain centers had a greater number of MAEs, the complications were less severe. CONCLUSIONS: MAE rates after elective EVAR vary widely. However, centers with higher MAE rates tended to have less severe complications, suggesting that observed MAE rates may not be a good measure of outcomes assessment after elective EVARs
    corecore