25 research outputs found

    Digital and Microscopic Tools for Ultimate Esthetics and Precision

    Get PDF
    Objective: This clinical report describes and illustrates step-by-step protocols for interdisciplinary esthetic treatment with current digital and microscopic tools. Clinical Considerations: Digital dentistry is no longer limited to impression making and restoration fabrication but starts already in the diagnostic and treatment planning phase. In particular, digital smile design tools have significantly improved clinical and laboratory workflows, allowing for natural and facially driven smiles, based on the patient\u27s specific needs and preferences. Digital technologies also facilitate high precision and accuracy in the laboratory, which are interconnected with the quality of the clinical care. Precision and minimally invasive dentistry require visual magnification aids through high-power loupes or, even better, surgical microscopes. For optimal clinical success, however, these tools must be integrated into efficient workflows and made part of a comprehensive clinical and laboratory concept. Conclusions: Digital and high-magnification tools in clinics and dental laboratories facilitate highly esthetic and precise outcomes when integrated into a comprehensive treatment concept. Clinical Significance: While a plethora of new tools and technologies is available for the dental laboratory and clinical practice, they can be daunting. Clear step-by-step workflows and protocols must be followed to apply them in a most efficient and effective manner for optimal outcomes. © 2022 Wiley Periodicals LLC

    Predictable Immediate Implant Placement and Restoration in the Esthetic Zone

    Get PDF
    This article describes a comprehensive step-by-step protocol for immediate implant placement and restoration in the esthetic zone. Clinical Considerations Immediate implant placement into fresh extraction sockets and immediate restoration have become widely accepted, demonstrating long-term success rates that are comparable with traditional delayed implant protocols. However, they are technique sensitive and require proper treatment planning as well as meticulous execution to be predictable and successful in the long term. This is particularly important in the esthetic zone, where even minor aberrations and mistakes can have devastating consequences, and especially in younger patients, where esthetic and functional outcomes should remain stable for years and possibly decades to come. The eight critical steps for predictable immediate implant placement include: provisional restoration of the failing tooth and presurgical phase, atraumatic tooth extraction, initial implant osteotomy, 3D bone graft packing, guided implant placement with a surgical guide, customized abutment insertion, provisional crown relining, and placement of a connective tissue graft from tuberosity. Immediate implant protocols in the esthetic zone require thorough planning and execution in the proper sequence. Each one of the critical steps discussed in this article has its own importance and challenges, which are critically assessed based on current scientific evidence. © 2021 Wiley Periodicals LL

    Advances in Esthetic Dentistry

    Get PDF

    Relationship Between Air-Blowing Duration and Bond Strengths of Three Adhesive Systems to Dentin After Thermal Aging

    Get PDF
    The purpose was to evaluate the effect of air-blowing duration of three different adhesive systems on immediate or thermal aged resin-dentin shear bond strength (SBS). Human dentin surfaces were bonded with: one-step (Bond Force, BF), two-step (FL-Bond II, FLB) and three-step (Scotch Bond Multi-Purpose, SBMP) adhesive systems. Bonded surfaces from each group were air-blown for 0, 5, or 10 s and cured. Composite cylinders were built on the treated surfaces and cured. Half of the specimens from each group were tested immediately and the other halves were tested after thermal aging. Statistical analysis showed signifcant decrease in SBS after thermal aging compared to immediate testing in all groups, except BF after 5 s air-blowing or FLB and SBMP with no air-blowing (p\u3e0.05). The results suggested that 5 s air-blowing is necessary to obtain a stable SBS for BF. However, extended airblowing duration of FLB and SBMP decreased the SBS significantly after thermal aging

    Diagnosis of Biofilm-Associated Peri-Implant Disease Using a Fluorescence-Based Approach

    Get PDF
    Dental implants have become a routine component of daily dental practice and the demand for dental implants is expected to increase significantly in the future. Despite the high success rates of dental implants, failures do occur, resulting in discomfort, rampant destruction of the oral health, or painful and costly surgical replacement of a failed implant. Peri-implant diseases are inflammatory conditions affecting the soft/hard tissues surrounding a functional dental implant. Plenty of experimental evidence indicates that the accumulation of dental plaque at the soft tissue– implant interface and the subsequent local inflammatory response seems to be key in the pathogenesis of the peri-implant mucositis. Such peri-implant–soft tissue interface is less effective than natural teeth in resisting bacterial invasion, enhancing vulnerability to subsequent peri-implant disease. Furthermore, in certain individuals, it will progress to peri-implantitis, resulting in alveolar bone loss and implant failure. Although early diagnosis and accurate identification of risk factors are extremely important to effectively prevent peri-implant diseases, current systematic reviews revealed that a uniform classification and diagnostic methodology for peri-implantitis are lacking. Recent progress on fluorescence-based technology enabled rapid diagnosis of the disease and effective removal of plaques. Here, we briefly review biofilm-associated peri-implant diseases and propose a fluorescence-based approach for more accurate and objective diagnoses. A fluorescence-based diagnosis tool through headlights combined with special-filtered dental loupes may serve as a hands-free solution for both precise diagnosis and effective removal of plaque-biofilms. © 2021 by the authors. Licensee MDPI, Basel, Switzerland

    3D Printed Complete Removable Dental Prostheses: a Narrative Review

    Get PDF
    Background: The purpose of this paper is to review the available literature on three-dimensionally printed complete dentures in terms of novel biomaterials, fabrication techniques and workflow, clinical performance and patient satisfaction. Methods: The methodology included applying a search strategy, defining inclusion and exclusion criteria, selecting studies and forming tables to summarize the results. Searches of PubMed, Scopus, and Embase databases were performed independently by two reviewers to gather literature published between 2010 and 2020. Results: A total of 126 titles were obtained from the electronic database, and the application of exclusion criteria resulted in the identification of 21 articles pertaining to printed technology for complete dentures. Current innovations and developments in digital dentistry have successfully led to the fabrication of removable dental prostheses using CAD/CAM technologies. Milled dentures have been studied more than 3D printed ones in the currently available literature. The limited number of clinical studies, mainly case reports, suggest current indications of 3D printing in denture fabrication process to be custom tray, record bases, trial, interim or immediate dentures but not definitive prostheses fabrication. Limitations include poor esthetics and retention, inability to balance occlusion and low printer resolution. Conclusions: Initial studies on digital dentures have shown promising short-term clinical performance, positive patient-related results and reasonable cost-effectiveness. 3D printing has potential to modernize and streamline the denture fabrication techniques, materials and workflows. However, more research is required on the existing and developing materials and printers to allow for advancement and increase its application in removable prosthodontics. © 2020, The Author(s)

    Quality of CAD-CAM inlays placed on aged resin-based composite restorations used as deep margin elevation: a laboratory study

    Get PDF
    OBJECTIVES To assess the impact of the age of resin-based composite (RBC) restorations used for deep margin elevation (DME) on the marginal quality and fracture resistance of inlays. MATERIALS AND METHODS Permanent human molars with direct RBC restorations, involving the mesial, occlusal, and distal surface (MOD), were allocated to four groups (each n = 12). Half of the teeth underwent thermomechanical loading including 240,000 occlusal load cycles and 534 thermal cycles (TML, 5 °C/55 °C; 49 N, 1.7 Hz). With RBC left in one proximal box as DME, all teeth received MOD inlays, made from lithium disilicate (LDS) or a polymer-infiltrated ceramic network material (PICN). The restored teeth underwent TML including 1.2 million occlusal cyclic loadings and 2673 thermal cycles. The marginal quality was assessed at baseline and after both runs of TML. Load-to-fracture tests were performed. The statistical analysis comprised multiple linear regressions (α = 0.05). RESULTS Simulated aging of RBC restorations had no significant effect on the marginal quality at the interface between the RBC and the tooth and the RBC and the inlay (p ≥ 0.247). Across time points, higher percentages of non-continuous margin were observed between the inlay and the tooth than between the tooth and the RBC (p ≤ 0.039). The age of the DME did not significantly affect the fracture resistance (p ≥ 0.052). CONCLUSIONS Artificial aging of RBC restorations used for DME had no detrimental effect on the marginal quality and fracture resistance of LDS and PICN inlays. CLINICAL RELEVANCE This laboratory study suggests that-in select cases-intact, direct RBC restorations not placed immediately before the delivery of an indirect restoration may be used for DME

    Clinical outcome of single porcelain-fused-to-zirconium dioxide crowns: a systematic review

    No full text
    STATEMENT OF PROBLEM The increasing demand by patients for esthetic and metal-free restorations has driven the development of ceramic restorations with good esthetic and mechanical stability. Recent clinical studies have investigated the use of zirconium dioxide as a core material for complete crowns and computer-aided-design/computer-aided-manufacturing fabricated restorations. PURPOSE The aim of this systematic review was to evaluate the clinical survival rates of porcelain-fused-to-zirconia (PFZ) single crowns on anterior and posterior teeth and to compare them with metal ceramic (MC) crowns. MATERIAL AND METHODS A systematic search was conducted with PubMed and manual research to identify literature written in English that refers to in vivo studies published from January 1, 1950 through July 1, 2011. Clinical trials that evaluated PFZ and MC single crowns on natural teeth were selected for further analysis. Titles and/or abstracts of articles identified through the electronic searches were reviewed and evaluated for appropriateness. In addition, a hand search of relevant dental journals was peformed, and reference lists of culled articles were screened to identify publications. RESULTS The search resulted in a total of 488 initial matches. Nineteen studies with a total of 3621 crowns met the inclusion criteria. The survival rates of PFZ crowns (total 300) ranged from 92.7% to 100% for a follow-up time of 24 to 39 months, whereas those of MC crowns (total 3321) ranged from 70% to 100% for a follow-up time of 12 to 298 months. Studies that reported long-term results were found only for the MC crown group. CONCLUSIONS The scientific clinical data available to compare PFZ and MC crowns are limited. The survival rates may well be influenced by the selection and appropriate use of the veneering ceramic, and, therefore, additional prospective long-term clinical trials are necessary to draw reliable conclusions

    Achieving Aesthetic and Restorative Excellence Using an Advanced Biomaterial: Part I

    No full text
    The following article of a 2 part series provides a review of composite resin technology and demonstrates the application of core clinical concepts in the restoration of the maxillary anterior segment taking aesthetic consideration of the anatomic variations of the adjacent teeth to produce direct composite resin restorations in harmony with the surrounding dentition

    Virtual implant planning in the edentulous maxilla: criteria for decision making of prosthesis design

    No full text
    OBJECTIVES To evaluate prosthetic parameters in the edentulous anterior maxilla for decision making between fixed and removable implant prosthesis using virtual planning software. MATERIAL AND METHODS CT- or DVT-scans of 43 patients (mean age 62 ± 8 years) with an edentulous maxilla were analyzed with the NobelGuide software. Implants (≥3.5 mm diameter, ≥10 mm length) were virtually placed in the optimal three-dimensional prosthetic position of all maxillary front teeth. Anatomical and prosthetic landmarks, including the cervical crown point (C-Point), the acrylic flange border (F-Point), and the implant-platform buccal-end (I-Point) were defined in each middle section to determine four measuring parameters: (1) acrylic flange height (FLHeight), (2) mucosal coverage (MucCov), (3) crown-Implant distance (CID) and (4) buccal prosthesis profile (ProsthProfile). Based on these parameters, all patients were assigned to one of three classes: (A) MucCov ≤ 0 mm and ProsthProfile≥45(0) allowing for fixed prosthesis, (B) MucCov = 0-5 mm and/or ProsthProfile = 30(0) -45(0) probably allowing for fixed prosthesis, and (C) MucCov ≥ 5 mm and/or ProsthProfile ≤ 30(0) where removable prosthesis is favorable. Statistical analyses included descriptive methods and non-parametric tests. RESULTS Mean values were for FLHeight 10.0 mm, MucCov 5.6 mm, CID 7.4 mm, and ProsthProfile 39.1(0) . Seventy percent of patients fulfilled class C criteria (removable), 21% class B (probably fixed), and 2% class A (fixed), while in 7% (three patients) bone volume was insufficient for implant planning. CONCLUSIONS The proposed classification and virtual planning procedure simplify the decision-making process regarding type of prosthesis and increase predictability of esthetic treatment outcomes. It was demonstrated that in the majority of cases, the space between the prosthetic crown and implant platform had to be filled with prosthetic materials
    corecore