695 research outputs found

    Cutaneous Infrared Thermometry for Detecting Febrile Patients

    Get PDF
    We assessed the accuracy of cutaneous infrared thermometry, which measures temperature on the forehead, for detecting patients with fever in patients admitted to an emergency department. Although negative predictive value was excellent (0.99), positive predictive value was low (0.10). Therefore, we question mass detection of febrile patients by using this method

    A re-appraisal of the reliability of the 20 m multi-stage shuttle run test

    Get PDF
    This is the author's PDF version of an article published in European journal of applied physiology in 2007. The original publication is available at www.springerlink.co

    Accuracy of SenseWear Pro2 armband to predict resting energy expenditure in childhood obesity.

    Get PDF
    OBJECTIVE: We evaluate the accuracy of the SenseWear Pro2 Armband (SWA) in estimating resting energy expenditure (REE) in children and adolescents with obesity, using indirect calorimetry (IC) as a reference. DESIGN AND METHODS: REE was assessed using both the SWA and IC in 40 obese subjects (26 M/14 F, age 11.5±2.57 years, z-score BMI 3.14±0.53). The agreement between methods was assessed by the Bland-Altman procedure. The relationship between REE assessments and patients' characteristics was also analyzed. RESULTS: SWA- and IC-derived estimates of REE showed a significant correlation (r=0.614; P<0.001), but the SWA overestimated mean REE by 13% (P<0.001). Age and kg of fat-free mass (kgFFM) were significantly correlated with both REE estimation by SWA (r=0.434 and r=0.564; respectively) and IC (r=0.401 and r=0.518; respectively). Only kgFFM was demonstrated to be the main predictor factor of REE variability (r2 79% SWA; 75% IC). CONCLUSIONS: The SWA overestimated mean REE in childhood obesity, suggesting that the SWA and IC are not yet interchangeable methods. This would require improving the SWA by developing better algorithms for predicting REE and, probably, bias in each individual REE could be reduced by an adjustment for subjects' kgFFM

    Impact of UV Radiation from Giant Spirals on the Evolution of Dwarf Galaxies

    Full text link
    We show that ultraviolet radiation, with wavelengths shorter than 2000 A, escaping from the disks of giant spirals could be one of the principal factors affecting the evolution of low mass satellite galaxies. We demonstrate, using a semi-qualitative model, that the Lyman continuum part of the radiation field can lead to ionization of the ISM of the dwarf galaxies through the process of photoevaporation, making the ISM virtually unobservable. The FUV part (912 < lambda < 2000 A) is shown to dominate over the internal sources of radiation for most of the Galactic dwarf spheroidals. The proposed environmental factor could be at least partially responsible for the bifurcation of the low mass proto-galaxies into two sequences - dwarf irregulars and dwarf spheroidals. We discuss many peculiarities of the Local Group early-type dwarfs which can be accounted for by the impact of the UV radiation from the host spiral galaxy (Milky Way or M31).Comment: 15 pages, 12 figures. Accepted for publication in MNRAS. More consistent photoionization model is used in Sect. 2. All main results stay unchange

    Validation of the SenseWear armband in circuit resistance training with different loads

    Get PDF
    The use of the SenseWear™ armband (SWA), an objective monitor of physical activity, is a relatively new device used by researchers to measure energy expenditure. These monitors are practical, relatively inexpensive and easy-to-use. The aim of the present study was to assess the validity of SWAs for the measurement of energy expenditure (EE) in circuit resistance training (CRT) at three different intensities in moderately active, healthy subjects. The study subjects (17 females, 12 males) undertook CRT at 30, 50 and 70% of the 15 repetition maximum for each exercise component wearing an SWA as well as an Oxycon Mobile (OM) portable metabolic system (a gold standard method for measuring EE). The EE rose as exercise intensity increased, but was underestimated by the SWAs. For women, Bland-Altman plots showed a bias of 1.13 ± 1.48 METs and 32.1 ± 34.0 kcal in favour of the OM system, while for men values of 2.33 ± 1.82 METs and 75.8 ± 50.8 kcal were recorded

    The Dutch version of the Oral Health Impact Profile (OHIP-NL): Translation, reliability and construct validity

    Get PDF
    Background The purpose of this study was to make a cross-culturally adapted, Dutch version of the Oral Health Impact Profile (OHIP), a 49-item questionnaire measuring oral health-related quality of life, and to examine its psychometric properties. Methods The original English version of the OHIP was translated into the Dutch language, following the guidelines for cross-cultural adaptation of health-related quality of life measures. The resulting OHIP-NL's psychometric properties were examined in a sample of 119 patients (68.9 % women; mean age = 57.1 ± 12.2 yrs). They were referred to the clinic of Prosthodontics and Implantology with complaints concerning their partial or full dentures or other problems with missing teeth. To establish the reliability of the OHIP-NL, internal consistency and test-retest reliability (N = 41; 1 - 2 weeks interval) were examined, using Cronbach's alpha and intraclass correlation coefficients (ICC), respectively. Further, construct validity was established by calculating ANOVA. Results Internal consistency and test-retest reliability were excellent (Cronbach's alpha = 0.82 - 0.97; ICC = 0.78 - 0.90). In addition, all associations were significant and in the expected direction. Conclusion In conclusion: the OHIP-NL can be considered a reliable and valid instrument to measure oral health-related quality of life

    A Search for Very Extended Ionized Gas in Nearby Starburst and Active Galaxies

    Get PDF
    We report the results from a pilot study of 10 nearby starburst and active galaxies conducted with the Taurus Tunable Filter (TTF) on the Anglo-Australian and William Herschel Telescopes. The main purpose of this imaging survey is to search for warm emission-line gas on the outskirts (galactocentric distances R > 10 kpc) of galaxies to provide direct constraints on the size and geometry of the ``zone of influence'' of these galaxies on their environment. Gaseous complexes or filaments larger than ~ 20 kpc are discovered or confirmed in six of the galaxies in the sample (NGC 1068, NGC 1482, NGC 4388, NGC 6240, NGC 7213, and MR 2251-178). Slightly smaller structures are seen for the first time in the ionization cones and galactic winds of NGC 1365, NGC 1705, Circinus galaxy, and ESO484-G036. The TTF data are combined with new optical long-slit spectra as well as published and archived radio and X-ray maps to constrain the origin and source of ionization of these filaments. A broad range of phenomena is observed, including large-scale ionization cones and galactic winds, tidal interaction, and ram-pressure stripping by an intracluster medium. The source of ionization in this gas ranges from shock ionization to photoionization by the central AGN or in-situ hot young stars. The sample is too small to draw statistically meaningful conclusions about the extent and properties of the warm ionized medium on large scale and its relevance to galaxy formation and evolution. The next generation of tunable filters on large telescopes promises to improve the sensitivity to faint emission-line fluxes at least tenfold and allow systematic surveys of a large sample of emission-line galaxies.Comment: 17 pages + 20 gif figures (high-resolution color version of these gif figures will be available with the electronic version of the published paper). Accepted for publication in the Astronomical Journal, November 2003 issu

    Extracellular ascorbate modulates glutamate dynamics: role of behavioral activation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>A physiological increase in extracellular ascorbate (AA), an antioxidant vitamin found throughout the striatum, elevates extracellular glutamate (GLU). To determine the role of behavioral arousal in this interaction, microdialysis was used to measure striatal GLU efflux in rats tested in either a lights-off or lights-on condition while reverse dialysis either maintained the concentration of AA at 250 μM or increased it to 1000 μM to approximate endogenous changes.</p> <p>Results</p> <p>When lights were off, both locomotion and GLU increased regardless of AA dose. In contrast, animals in the lights-on condition were behaviorally inactive, and infusion of 1000, but not 250, μM AA significantly increased extracellular GLU. Interestingly, when ambient light returned to the lights-off group, 1000 μM prolonged the GLU increase relative to the 250 μM group.</p> <p>Conclusion</p> <p>Our results not only support evidence that elevated striatal AA increases extracellular GLU but also indicate that this effect depends on behavioral state and the corresponding level of endogenous GLU release.</p

    A new efficient trial design for assessing reliability of ankle-brachial index measures by three different observer groups

    Get PDF
    BACKGROUND: The usual method of assessing the variability of a measure such as the ankle brachial index (ABI) as a function of different observer groups is to obtain repeated measurements. Because the number of possible observer-subject combinations is impractically large, only a few small studies on inter- and intraobserver variability of ABI measures have been carried out to date. The present study proposes a new and efficient study design. This paper describes the study methodology. METHODS: Using a partially balanced incomplete block design, six angiologists, six primary-care physicians and six trained medical office assistants performed two ABI measurements each on six individuals from a group of 36 unselected subjects aged 65–70 years. Each test subject is measured by one observer from each of the three observer groups, and each observer measures exactly six of the 36 subjects in the group. Each possible combination of two observers occurs exactly once per patient and is not repeated on a second subject. The study involved four groups of 36 subjects (144), plus standbys. RESULTS: The 192 volunteers present at the study day were similar in terms of demographic characteristics and vascular risk factors: mean age 68.6 ± 1.7; mean BMI 29.1 ± 4.6; mean waist-hip ratio 0.92 ± 0.09; active smokers 12%; hypertension 60.9%; hypercholesterolemia 53.4%; diabetic 17.2%. A complete set of ABI measurements (three observers performing two Doppler measurements each) was obtained from 108 subjects. From all other subjects at least one ABI measurement was obtained. The mean ABI was 1.08 (± 0.13), 15 (7.9%) volunteers had an ABI <0.9, and none had an ABI >1.4, i.e. a ratio that may be associated with increased stiffening of the arterial walls. CONCLUSION: This is the first large-scale study investigating the components of variability and thus reliability in ABI measurements. The advantage of the new study design introduced here is that only one sixth of the number of theoretically possible measurements is required to obtain information about measurement errors. Bland-Altman plots show that there are only small differences and no systematic bias between the observers from three occupational groups with different training backgrounds
    corecore