950 research outputs found
Monte carlo study of the physics performance of a digital hadronic calorimeter
A digital hadronic calorimeter using MICROMEGAS as active elements is a very
promising choice for particle physics experiments at future lepton colliders.
These experiments will be optimized for application of the particle flow
algorithm and therefore require calorimeters with very fine lateral
segmentation. A 1 m2 prototype based on MICROMEGAS chambers with 1x1 cm2
readout pads is currently being developed at LAPP. The GEANT4 simulation of the
physics performance of a MICROMEGAS calorimeter is presented. The main
characteristics, such as energy resolution, linearity and shower profile, have
been carefully examined for various passive materials with pions over a wide
energy range from 3 to 200 GeV. The emphasis is put on the comparison of the
analog and digital readout.Comment: 8 pages, 5 figures, MPGD09 conferenc
Vitry-sur-Orne
Identifiant de l'opération archéologique : F1357200100153 Date de l'opération : 2001 (EX) La commune de Vitry-sur-Orne est située sur la rive gauche de l'Orne, affluent gauche de la Moselle, à 16 km au nord de Metz et à 10 km au sud de Thionville. La ZAC de la Plaine s'étend sur l'ancien ban du village disparu de « Vallange », sur une terrasse de l'Orne, à environ 20 m au-dessus du lit majeur de la rivière. Le substrat y est constitué de graviers calcaires recouverts par endroits de limon bru..
Vitry-sur-Orne – ZAC de la Plaine et dispositif d'assainissement
Identifiant de l'opération archéologique : F1357200100153 Date de l'opération : 2001 (EX) La commune de Vitry-sur-Orne est située sur la rive gauche de l'Orne, affluent gauche de la Moselle, à 16 km au nord de Metz et à 10 km au sud de Thionville. La ZAC de la Plaine s'étend sur l'ancien ban du village disparu de « Vallange », sur une terrasse de l'Orne, à environ 20 m au-dessus du lit majeur de la rivière. Le substrat y est constitué de graviers calcaires recouverts par endroits de limon bru..
Physics performances for Scalar Electrons, Scalar Muons and Scalar Neutrinos searches at CLIC
The determination of scalar leptons and gauginos masses is an important part
of the program of spectroscopic studies of Supersymmetry at a high energy
linear collider. In this talk we present results of a study of pair produced
Scalar Electrons, Scalar Muons and Scalar Neutrinos searches in a
Supersymmetric scenario at 3 TeV at CLIC. We present the performances on the
lepton energy resolution and report the expected accuracies on the production
cross sections and on the scalar leptons and gauginos masses.Comment: Linera Collider Workshop, LCWS11, 6 pages, 2 figures, 4 table
Physics performances for Z' searches at 3 TeV and 1.5 TeV CLIC
Extra neutral gauge bosons (Z') are predicted in many extensions of the
Standard Model (SM). In the minimal anomaly-free Z' model (AFZ'), the
phenomenology is controlled by only three parameters beyond the SM ones, the Z'
mass and two effective coupling constants g'_Y and g'_{BL}. We study the Z'
5-sigma discovery potential in e+e- collisions at 1.4 and 3 TeV CLIC. Assuming
LHC discovers a Z' of 5 TeV mass, the expected accuracies on the Z'mu+mu-
couplings are presented. We discuss also the requirements on detector
performance and beam polarization.Comment: 12 pages, CLIC Study repor
Sarrebourg – Golf du pays de Sarrebourg, parcours 9 trous
Identifiant de l'opération archéologique : F1357200100130 Date de l'opération : 2001 (EV) Le terrain, de 5 500 m2, est situé à 2 km à l'ouest du centre historique de la ville. Il s'agit d'une extension du golf existant. Aucun vestige archéologique n'y a été relevé
Status of the Micromegas semi-DHCAL
The activities towards the fabrication and test of a 1 m3 semi-digital
hadronic calorime- ter are reviewed. The prototype sampling planes would
consist of 1 m2 Micromegas chambers with 1 cm2 granularity and embedded 2 bits
readout suitable for PFA calorime- try at an ILC detector. The design of the 1
m2 chamber is presented first, followed by an overview of the basic performance
of small prototypes. The basic units composing the 1 m2 chamber are 32 \times
48 cm2 boards with integrated electronics and a micro-mesh. Results of
character- ization tests of such boards are shown. Micromegas as a proportional
detector is well suited for semi-digital hadronic calorimetry. In order to
quantify the gain in perfor- mance when using one or more thresholds,
simulation studies are being carried out, some of which will be reported in
this contribution
- …