26 research outputs found

    Results of conjunctivo-dacryocystorhinostomy with low-density polyethylene tube implant

    Get PDF
    Purpose: To analyze the postoperative complications of conjunctivodacryocystorhinostomy with low-density polyethylene tube and the possible correlations between the various etiologies and complications and surgical success rate. Methods: The study was carried out on 35 lacrimal apparatus of 34 patients who were submitted to conjunctivodacryocystorhinostomy with low-density polyethylene tube during a six-year period, from August 1991 to November 1997. With the aim of studying the possible correlations between the findings (etiology x complications and etiology x success rate) exact Fisher's test was carried out. Results: The most important etiologies were chronic dacryocystitis and failure of dacryocystorhinostomy (53.9%) followed by traumatisms (16.3%). The complication rate was 74.3%. The surgical success rate in one intervention was 25.7%. After two or more surgeries, 17 tubes became pervious and well-located (48.6%). Unsuccessful procedures occurred in 25.7% of the lacrimal apparatus. There was no significant correlation between etiology and complication occurrence neither between etiology and surgical success. Conclusions: There is no difference between complications and success in this study and those reported in the international literature. These findings were not correlated with the obstruction etiology. The advantages of low-density polyethylene tube are its great availability, the easy manufacture in the intraoperative period according to the lenght and width needs of and, finally, it can be exchanged for borosilicate glass when the edema regress.Objetivos: Estabelecer quais são as complicações pós-operatórias da conjuntivodacriocistorrinostomia (CDCR) com implante de prótese lacrimal de polietileno de baixa densidade e relacionar a etiologia da obstrução e o aparecimento destas complicações e, conseqüentemente, o sucesso pós-operatório. Métodos: Foram analisadas 35 vias lacrimais submetidas a conjuntivodacriocistorrinostomia com implante de prótese lacrimal de polietileno. Com a finalidade de estudar as possíveis relações entre as variáveis encontradas (etiologia x complicações e etiologia x sucesso) realizou-se o teste exato de Fisher. Resultados: As etiologias de obstrução mais freqüentes foram a dacriocistite crônica e pós-dacriocistorrinostomia que, em conjunto, foram responsáveis por 53,9% dos casos. Os traumatismos ocasionaram 16,3% das obstruções. A taxa de complicações encontrada foi 74,3%. A conjuntivodacriocistorrinostomia apresentou sucesso em uma única intervenção cirúrgica em 9 vias lacrimais (25,7%). Após duas ou mais intervenções cirúrgicas, 17 próteses lacrimais tornaram-se pérvias e bem localizadas (48,6%). O insucesso ocorreu em 9 vias lacrimais (25,7%). Não houve relação estatisticamente significante entre etiologia e ocorrência de complicações nem entre etiologia e sucesso pós-operatório. Conclusões: As complicações encontradas são similares às descritas na literatura e não tiveram relação com a etiologia da obstrução canalicular. O mesmo pode ser considerado no que se refere ao sucesso da conjuntivodacriocistorrinostomia. As vantagens da prótese lacrimal de polietileno de baixa densidade são a grande disponibilidade, a fácil confecção no per-operatório de acordo com o comprimento e o diâmetro do colarete desejados e pode ser substituída pela prótese lacrimal de vidro de borosilicato assim que o edema regrida.Universidade Federal de São Paulo (UNIFESP) Escola Paulista de Medicina Departamento de OftalmologiaSanta Casa de São Paulo Departamento de OftalmologiaUNIFESP, EPM, Depto. de OftalmologiaSciEL

    Canaliculus obstruction etiology

    Get PDF
    Purpose: There are few Brazilian studies about canaliculus obstruction etiology. To analyze the various etiologies of the obstruction was the goal in the present study. Methods: The study was carried out on 63 lacrimal apparatus of 59 patients who were submitted to external examination, biomicroscopy, Jones' I and II tests and canaliculus measurement. Results: The most important etiologies were chronic dacryocystitis and failure of dacryocystorhinostomy (53.9%) followed by traumatisms caused by aggression, car accidents and a dog bite. Agenesis contributed with 9.5% and less frequent were canaliculus inflammations and infections, surgeries, radiotherapy and idiopathic obstructions. Conclusions: There is no diference between the findings of this study and those re-ported in the international literature.Objetivo: São raros os artigos encontrados na literatura nacional sobre a etiologia da obstrução alta das vias lacrimais de drenagem. O objetivo deste estudo foi, portanto, analisar as diversas etiologias encontradas no nosso meio. Métodos: Foram estudadas 63 vias lacrimais (59 pacientes examinados) com diagnóstico de obstrução alta feito, na maioria dos casos, apenas por meio da propedêutica clínica que incluiu a inspecção, a biomicroscopia, os testes de Jones I e II e a cateterização dos canalículos lacrimais. O estudo foi realizado nos Departamentos de Oftalmologia da Universidade Federal de São Paulo (UNIFESP) - Escola Paulista de Medicina e do Hospital Central da Santa Casa de Misericórdia de São Paulo, no período compreendido entre 1991 e 1997. Resultados: As etiologias mais freqüentes foram a dacriocistite crônica e pós-dacriocistorrinostomia que, em conjunto, foram responsáveis por 53,9% dos casos. Em seguida apareceram os traumatismos, nos quais houve 4 agressões, 5 acidentes automobilísticos e uma mordida de cão. As agenesias contribuíram com 9,5% e menos freqüentes foram a canaliculopatia estenosante, os procedimentos cirúrgicos e radioterápicos no canto medial e as obstruções idiopáticas. Conclusões: Baseando-se nos dados encontrados, pode-se inferir que a etiologia da obstrução alta das vias lacrimais de drenagem em nosso meio não difere da referida na literatura internacional.Universidade Federal de São Paulo (UNIFESP) Escola Paulista de Medicina Departamento de OftalmologiaSanta Casa de São Paulo Seção de Vias LacrimaisUniversidade Federal de São Paulo (UNIFESP) Escola Paulista de MedicinaUNIFESP, EPM, Depto. de OftalmologiaUNIFESP, EPMSciEL

    Obstrucao primaria do ducto nasolacrimal: proposta de classificacao histopatologica

    No full text
    BV UNIFESP: Teses e dissertaçõe

    Microscopic alterations in silicone tubes surface after application of ophthalmological lubricants

    No full text
    Objective: To identify microscopic morphological alterations in the surface of silicone tubes used for intubation of the lachrymal system after exposure to ophthalmological lubricants. Methods: Experimental, descriptive and longitudinal study consisted of the application of ophthalmological lubricants in silicone tubes. The tubes were divided in: Group 1 (Cylocort®), 2 (Epitezan®), 3 (Labcaína®), 4 (Liposic®), 5 (Maxinom®) and 6 (Vista Gel®). One tube was not exposed to any lubricant, used as control. The tubes were observed and photographed after 2 hours, 30 days, 45 days before and after cleaning the surface and lumen. The following aspects were observed: surface (regularity, transparency, quantity, size and shape of the substances) and lumen (obstruction). Results: Control: irregular surface with pores after 2 hours: Group 1 – irregular surface with presence of film; Groups 2, 3 and 5 – abundant and irregular quantity of ointment at the surface; Group 4 – discrete modification at the surface; Group 6 – growth of pigmented (brownish) structures with filaments in the lumen, with discrete film in the surface. 30 Days: Groups 1, 4 and 5 – increase of the irregular superficial film; Group 2 – crust with notorious horizontal lines; Group 3 – diminution of the superficial film; Group 4 – crust less evident. Group 6 – increase of the structure seen with 2 hours of exposition, arboriform aspect. Forty-five days pre cleaning: Group 4 – diminution of the surface crust; Group 6 – expansion of the arboriform structure; unaltered findings in other groups. 45 days after cleaning: Groups 1 and 5 – light diminution of the surface crust; Groups 2, 3 and 4 – kept the modifications; Group 6 – the structure inside the lumen was not identified, clear surface, without evidence of film. Conclusions: Microscopic morphological alterations in the surface and lumen of silicone tubes can occur when those remain in contact with determined ophthalmological lubricants
    corecore