4 research outputs found
Recommended from our members
Contamination source review for Building E3613, Edgewood Area, Aberdeen Proving Ground, Maryland
This report was prepared by Argonne National Laboratory (ANL) to document the results of a contamination source review of Building E3613 at the Aberdeen Proving Ground (APG) in Maryland. The report may be used to assist the U.S. Army in planning for the future use or disposition of this building, The review included a historical records search, physical inspection, photographic documentation, geophysical investigation, and collection of air samples. The field investigations were performed by ANL during 1994 and 1995. Building E3613 (APG designation) is located in the Canal Creek Area of APG. The building was constructed in 1954 for use as a change house, office, and storage building in support of the white phosphorus smoke program. The building has not been used since 1988. During an inspection in 1988, asbestos was listed as the only potential contaminant. The physical inspection and photographic documentation of Building E3613 were completed in November 1994. At the time of the inspection, Building E3613 was inactive and in disrepair. The single-story, rectangular structure contains five rooms and measures 16 ft 2 in. by 32 ft. The building is wood frame construction with a gabled roof. The exterior walls and roof are constructed of wood covered with asphalt sheeting. The building rests on a concrete foundation. The interior walls are 6-in.-thick wood, and the ceiling is assumed to be white drywall nailed to a wooden frame. Overhead steam pipes supported by vertical pipes traverse the area. Two concrete footings for guy wires that support the overhead steam pipes are located north and west of the building. Four additional vertical pipes exit the ground east of the building
Recommended from our members
Contamination source review for Building E5974, Edgewood Area, Aberdeen Proving Ground, Maryland
This report documents the results of a contamination source review of Building E5974 at the Aberdeen Proving Ground (APG) in Maryland. The primary mission at APG has been the testing and evaluation of US Army warfare materials. Since its beginning in 1917, the Edgewood Area of APG has been the principal location for chemical warfare agent research, development, and testing in the US. APG was also used for producing chemical warfare agents during both world wars, and it has been a center for the storage of chemical warfare material. An attempt was made to identify and define areas of toxic or hazardous contaminants and to assess the physical condition and accessibility of APG buildings. The information obtained from this review may be used to assist the US Army in planning for the future use or disposition of the buildings. The contamination source review consisted of the following tasks: historical records search, physical inspection, photographic documentation, geophysical investigation, and collection of air samples
Recommended from our members
X-ray fluorescence investigation of heavy-metal contamination on metal surfaces in the Pilot Plant Complex, Aberdeen Proving Ground, Maryland
A field program using a portable x-ray fluorescence (XRF) instrument was carried out to obtain data on loadings of RCRA-regulated heavy metals in paint on metal surfaces within the Pilot Plant Complex at Aberdeen Proving Ground, Maryland. Measured loadings of heavy metals were sufficiently small that they do not present problems for either human exposure or the disposition of building demolition rubble. An attempt to develop an external calibration of the XRF instrument for cadmium, chromium, and lead was unsuccessful. Significant substrate effects were observed for cadmium and chromium; for accurate results for these elements, it appears necessary to calibrate by using a sample of the actual metal substrate on which the paint is located. No substrate effects were observed for lead, but the use of lead L-shell x-ray emission lines in the instrument mode utilized in this study appears to result in a significant underestimate of the lead loading due to self-absorption of these emissions