Efficacy and Safety of Appropriate Shocks and Antitachycardia Pacing in Transvenous and Subcutaneous Implantable Defibrillators: Analysis of All Appropriate Therapy in the PRAETORIAN Trial.
BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) showed noninferiority of subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous implantable cardioverter defibrillator (TV-ICD) with regard to inappropriate shocks and complications. In contrast to TV-ICD, S-ICD cannot provide antitachycardia pacing for monomorphic ventricular tachycardia. This prespecified secondary analysis evaluates appropriate therapy and whether antitachycardia pacing reduces the number of appropriate shocks. METHODS: The PRAETORIAN trial was an international, investigator-initiated randomized trial that included patients with an indication for implantable cardioverter defibrillator (ICD) therapy. Patients with previous ventricular tachycardia <170 bpm or refractory recurrent monomorphic ventricular tachycardia were excluded. In 39 centers, 849 patients were randomized to receive an S-ICD (n=426) or TV-ICD (n=423) and were followed for a median of 49.1 months. ICD programming was mandated by protocol. Appropriate ICD therapy was defined as therapy for ventricular arrhythmias. Arrhythmias were classified as discrete episodes and storm episodes (≥3 episodes within 24 hours). Analyses were performed in the modified intention-to-treat population. RESULTS: In the S-ICD group, 86 of 426 patients received appropriate therapy, versus 78 of 423 patients in the TV-ICD group, during a median follow-up of 52 months (48-month Kaplan-Meier estimates 19.4% and 17.5%; P=0.45). In the S-ICD group, 83 patients received at least 1 shock, versus 57 patients in the TV-ICD group (48-month Kaplan-Meier estimates 19.2% and 11.5%; P=0.02). Patients in the S-ICD group had a total of 254 shocks, compared with 228 shocks in the TV-ICD group (P=0.68). First shock efficacy was 93.8% in the S-ICD group and 91.6% in the TV-ICD group (P=0.40). The first antitachycardia pacing attempt successfully terminated 46% of all monomorphic ventricular tachycardias, but accelerated the arrhythmia in 9.4%. Ten patients with S-ICD experienced 13 electrical storms, versus 18 patients with TV-ICD with 19 electrical storms. Patients with appropriate therapy had an almost 2-fold increased relative risk of electrical storms in the TV-ICD group compared with the S-ICD group (P=0.05). CONCLUSIONS: In this trial, no difference was observed in shock efficacy of S-ICD compared with TV-ICD. Although patients in the S-ICD group were more likely to receive an ICD shock, the total number of appropriate shocks was not different between the 2 groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022
Device-related complications in the subcutaneous and transvenous ICD: a secondary analysis of the PRAETORIAN trial.
BACKGROUND: The subcutaneous ICD (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the combined primary endpoint of inappropriate shocks and complications. This prespecified secondary analysis evaluates all complications in the PRAETORIAN trial. METHODS: The PRAETORIAN trial is an international, multicenter, randomised trial in which 849 patients with an indication for ICD therapy were randomised to receive an SICD (N = 426) or TV-ICD (N = 423) and followed for a median of 49 months. Endpoints were device-related complications, lead-related complications, systemic infections and the need for invasive interventions. RESULTS: Thirty-six device-related complications occurred in 31 patients in the S-ICD group of which bleedings were the most frequent. In the TV-ICD group 49 complications occurred in 44 patients of which lead-dysfunction was most frequent (HR 0.69; P =0.11). In both groups half of all complications were within 30 days after implantation. Lead-related complications and systemic infections occurred significantly less in the S-ICD group compared to the TV-ICD group (P <0.001, P =0.03 respectively). Significantly more complications required invasive interventions in the TV-ICD group compared to the S-ICD group (8.3% vs. 4.3%, HR 0.59; P =0.047). CONCLUSIONS: This secondary analysis shows that, lead-related complications and systemic infections are more prevalent in the TV-ICD group compared to the S-ICD group. In addition, complications in the TV-ICD group were more severe as they required significantly more invasive interventions. This data contributes to shared decision making in clinical practice
Recurrent cardiac ischemic events early after discontinuation of short-term heparin treatment in acute coronary syndromes - Results from the thrombolysis in myocardial infarction (TIMI) 11B and efficacy and safety of subcutaneous enoxaparin in non-Q-wave coronary events (ESSENCE) studies
AbstractObjectivesThe aim of this study was to determine whether discontinuation of low-molecular-weight heparin (LMWH) treatment results in a clustering of cardiac ischemic events as previously observed after cessation of unfractionated heparin (UFH) in acute coronary syndrome (ACS) patients.BackgroundClinical trials in patients with ACS have shown early recurrent ischemic events after discontinuation of UFH treatment. We analyzed whether LMWH cessation also results in early ischemic recurrence events and if continuation of a fixed-dose LMWH prevents this complication.MethodsThe combined incidence of death, myocardial infarction, or urgent revascularization in the first seven days after discontinuation of UFH (n = 3,012), short-term enoxaparin 1 mg/kg subcutaneously twice a day (n = 2,011), and short-term enoxaparin followed by prolonged enoxaparin 60 mg subcutaneously twice a day (n = 1,075) was analyzed from the combined Thrombolysis In Myocardial Infarction (TIMI) 11B/Efficacy and Safety of Subcutaneous Enoxaparin in Non–Q-Wave Coronary Events (ESSENCE) database in a per patient analysis.ResultsThe cessation of both UFH and short-term enoxaparin resulted in a similar clustering of recurrent ischemic events on the first day, with an incidence of the primary end point of 2.8% in both groups. Of all recurrent events in the first week after cessation, 40% occurred in the first 24 h. The continuation of a fixed-dose enoxaparin treatment prevented this early excess, with a first day incidence of 0.4% (p < 0.0001). The TIMI risk score characteristics predicted the incidence of early rebound ischemic events.ConclusionsThere is significant clustering of recurrent ischemic events within 24 h after cessation of both short-term UFH and enoxaparin treatment, and patients should be carefully monitored during that period. This early rebound may be prevented by continuation of a fixed dose of enoxaparin