2 research outputs found

    Efficacy of Ultrasonic-Assisted Curing Is Dependent on Muscle Size and Ultrasonication System

    No full text
    Ultrasound-assisted marinade is a promising technology for reducing the time of traditional immersion marination. This study evaluated the effect of the ultrasonic system (bath or probe, amplitude 50 or 100%) and muscle sample size (3 or 5 cm3) on physicochemical quality, yield (salt content, fresh weight, and relative fresh weight), and bacteria counts associated with pork. The results showed a significantly high salt (p < 0.0001) content in 3 cm3 (11.54%) and 5 cm3 (8.88%) samples after 24 h marination by immersion. The 3 cm3 cubes marinated in a 100% probe system for 20 min presented an amount of salt (9.55%) that was quite close to the controls. The 3 cm3 samples treated by immersion and in a 50% probe system gained more relative weight (in relation to the initial weight, 7.45 and 6.64%, respectively) after 7 d at 4 °C. Meanwhile the 5 cm3 cubes marinated by immersion gained 8.1%. The other treatments showed a weight loss after treatment. Although significant differences were found in the fresh weight and in water holding capacity (WHC) in the 3 and 5 cm3 meat samples, the relative fresh weight is a real measure of weight gain, more relevant for the industry. Thus, the samples with the highest salt transfer experienced a phenomenon of “dehydration”, retaining less water. The 3 and 5 cm3 cubes marinated by immersion presented orange color tones due to the long processing time, while the probe system produced redder and brighter tones. Ultrasound as a technology to assist in marinades is not efficient for bacteria control of mesophilic, psychrophilic, or coliform. However, a significant increase in lactic acid bacteria (LAB) counts may bring benefits for meat preservation during refrigerated storage

    The Physicochemical, Microbiological, and Structural Changes in Beef Are Dependent on the Ultrasound System, Time, and One-Side Exposition

    No full text
    The effect of high-intensity ultrasound (HIU) system (bath, 37 kHz and 90 W/cm2; or probe, 24 kHz and 400 W) and application time (25 or 50 min, one-side exposition) on the properties of bovine Longissimus lumborum after 7 d of storage at 4 °C was studied. The bath system significantly increased the lightness of the muscle, while other color parameters (a*, b*, hue, and chroma) were not different from the control. The water holding capacity and shear force decreased significantly (3.1–5% and 0.59–0.72 kgf, respectively) in sonicated meat independently of the system, favoring the tenderization of the muscle after storage. Microstructural changes observed in the HIU-exposed surface provided evidence of a higher area of interfibrillar spaces (1813 vs. 705 µm2 in the control), producing tenderization of the muscle, compared with the control. HIU significantly increased counts of total aerobic and coliform bacteria, especially after 50 min of ultrasonication. HIU also increased lactic acid bacterial counts in the bath system. Single-sided muscle exposition to ultrasound may produce sufficient significant changes in muscle properties, which could decrease long treatment times that would be needed for the exposition of both sides. HIU in bath systems increases tenderness by modifying meat ultrastructure, with no significant changes in physicochemical parameters. Nevertheless, microbiological quality may need to be considered during the process due to a slight increase in bacterial counts
    corecore