31 research outputs found

    Comparison of the acute outcome of two cryoballoon technologies for pulmonary vein isolation:An updated systematic review and meta-analysis

    Get PDF
    Initial experience suggests that the POLARx cryoballoon system (Boston Scientific) has a similar procedural efficacy and safety as Arctic Front Advance Pro (AFA-Pro, Medtronic). We performed an updated systematic review and meta-analysis comparing POLARx and AFA-Pro. Embase, MEDLINE, Web of Science, Cochrane, and Google Scholar databases were searched until 12/01/2022 for studies comparing POLARx versus AFA-Pro in patients undergoing pulmonary vein (PV) isolation for AF. A total of 8 studies, involving 1146 patients from 11 European centers were included (POLARx n = 317; AFA-Pro n = 819). There were no differences in acute PV isolation, procedure time, fluoroscopy time, ablation time, minimal esophageal temperature, and risk of phrenic nerve palsy or thromboembolic events. Balloon nadir temperatures were lower for POLARx in all PVs. Compared with AFA-Pro, POLARx had a higher rate of first freeze isolation in the left inferior PV (LIPV) (odds ratio [OR]: 2.60; 95 % confidence interval [CI]: 1.06 to 6.43; P = 0.04), higher likelihood of time-to-isolation (TTI) recording in LIPV (OR: 2.91; 95 % CI: 1.54 to 5.49; P = 0.001) and right inferior PV (OR: 3.23; 95 % CI: 1.35 to 7.74; P = 0.008). In contrast, the TTI in LIPV was longer with POLARx in comparison to AFA-Pro (mean difference: 7.61 sec; 95 % CI 2.43 to 12.8 sec; P = 0.004). In conclusion, POLARx and AFA-Pro have a similar acute outcome. Interestingly, there was a higher rate of TTI recording in the inferior PVs with POLARx. This updated meta-analysis provides new safety data on esophageal temperature and thromboembolic events

    Minimally interrupted novel oral anticoagulant versus uninterrupted vitamin K antagonist during atrial fibrillation ablation

    Get PDF
    The safety and efficacy of a minimally interrupted novel oral anticoagulant (NOAC) strategy at the time of atrial fibrillation (AF) ablation is uncertain. The purpose of this study was to compare rates of bleeding and thromboembolic events between minimally interrupted NOAC and uninterrupted vitamin K antagonist (VKA) in patients undergoing AF ablation.This was a retrospective single-center cohort study of consecutive patients who underwent AF catheter ablation between January 2013 and April 2017. Endpoints included major bleeding, clinically relevant non-major bleeding and systemic thromboembolic event from the time of ablation through 30 days. Bleeding events were defined by the Bleeding Academic Research Consortium (BARC) and International Society on Thrombosis and Haemostasis (ISTH).A total of 637 patients were included in the analysis, 520 patients used uninterrupted VKA and 117 patients minimally interrupted NOAC (dabigatran: n = 68; apixaban: n = 30; rivaroxaban, n = 14; edoxaban, n = 5). The rate of clinically relevant non-major bleeding was lower in the NOAC group in comparison to the VKA group (BARC type 2: 2.6% versus 8.3%, P = 0.03; ISTH: 0% versus 3.8%, P = 0.03). Rates of major bleeding were similar between groups (BARC type 3 to 5: 3.4% versus 4.2%, P = NS; ISTH: 6.0% versus 8.7%, P = NS; for NOAC and VKA groups, respectively). Rates of systemic embolism were 0% with minimally interrupted NOAC, and 0.6% with uninterrupted VKA (P = NS).In patients undergoing AF ablation, anticoagulation with minimally interrupted NOAC was associated with fewer clinically relevant non-major bleeding events in comparison with uninterrupted VKA without compromising thromboembolic safety

    Pocket hematoma after pacemaker or defibrillator surgery:Direct oral anticoagulants versus vitamin K antagonists

    Get PDF
    BACKGROUND: Direct oral anticoagulants (DOACs) are the preferred choice of oral anticoagulation in patients with atrial fibrillation (AF). Randomized trials have demonstrated the efficacy and safety of DOAC in patients undergoing a cardiac implantable electronic device procedure (CIED); however, there is limited real-world data. OBJECTIVE: To evaluate the outcome of patients undergoing an elective CIED procedure in a tertiary referral center with an interrupted DOAC or continued vitamin K antagonist (VKA) regimen. METHODS: This was a retrospective single-center study of consecutive patients with AF undergoing an elective CIED procedure between January 2016 and June 2019. The primary endpoint was a clinically significant pocket hematoma < 30 days after surgery. The secondary endpoint was any systemic thromboembolic complication < 30 days after surgery. RESULTS: Of a total of 1,033 elective CIED procedures, 283 procedures were performed in patients with AF using oral anticoagulation. One-third of the procedures were performed under DOAC (N = 81, 29%) and the remainder under VKA (N = 202, 71%). The DOAC group was younger, had less chronic renal disease, more paroxysmal AF and a lower HAS-BLED score. The VKA group more often underwent a generator change only in comparison to the DOAC group. Clinically significant pocket hematoma occurred in 5 patients (2.5%) in the VKA group and did not occur in the DOAC group (P = 0.33). There were no thromboembolic events reported. CONCLUSION: In patients with AF undergoing an elective CIED procedure, the risk of a pocket hematoma and a systemic thromboembolic event is comparably low when using either continued VKA or interrupted DOAC

    Complications in pulmonary vein isolation in the Netherlands Heart Registration differ with sex and ablation technique

    Get PDF
    Aims Pulmonary vein isolation (PVI) has become a cornerstone of the invasive treatment of atrial fibrillation. Severe complications are reported in 1-3% of patients. This study aims to compare complications and follow-up outcome of PVI in patients with atrial fibrillation. Methods and results The data were extracted from the Netherlands Heart Registration. Procedural and follow-up outcomes in patients treated with conventional radiofrequency (C-RF), multielectrode phased RF (Ph-RF), or cryoballoon (CB) ablation from 2012 to 2017 were compared. Subgroup analysis was performed to identify variables associated with complications and repeat ablations. In total, 13 823 patients (69% male) were included. The reported complication incidence was 3.6%. Patients treated with C-RF developed more cardiac tamponades (C-RF 0.8% vs. Ph-RF 0.3% vs. CB 0.3%, P Conclusion The reported complication rate during PVI was low. Patients treated with C-RF ablation were more likely to develop cardiac tamponades and vascular complications. Female sex was associated with more cardiac tamponade and bleeding complications

    Use of a novel integrated dilator-needle system in cryoballoon procedures: a zero-exchange approach

    Get PDF
    Background: Recently, a novel integrated dilator-needle system (AcQCross Qx, Acutus Medical) was introduced to reduce the number of exchanges for a transseptal access. This system can be used in combination with large bore sheaths. In this pilot study, we evaluated the safety and efficacy of a zero-exchange approach with the AcQCross system in cryoballoon procedures. Methods: In this retrospective single-center study, we included 40 patients (AcQCross: n = 20; control group: n = 20) who underwent a cryoballoon procedure for the treatment of atrial fibrillation. In the AcQCross and control group, patients underwent ablation with POLARx (Boston Scientific) and Arctic Front Advance Pro (AFA-Pro, Medtronic) in equal numbers (n = 10). In the AcQCross group, the AcQGuide Max sheath (Acutus Medical) was used in all POLARx cases. Results: The baseline characteristics of the study population were comparable between groups. In the AcQCross group, there was a reduction in procedure time (49.7 ± 9.0 min vs. 59.6 ± 8.1 min, P < 0.001) and time from puncture until balloon delivery (15.5 ± 6.8 min vs. 21.5 ± 7.4 min, P = 0.01) in comparison with the control group. The balloon in body time, fluoroscopy time, number of cryoapplications, and biophysical parameters were similar between groups. There was one temporary phrenic nerve injury in the AcQCross group. Importantly, no signs of air embolism were noted with the AcQGuide Max sheath. Conclusions: The use of the novel AcQCross system improves procedural efficacy in cryoballoon procedures by reducing the number of exchanges

    Accuracy of atrial fibrillation detection by an insertable cardiac monitor in patients undergoing catheter ablation: Results of the BioVAD study

    Get PDF
    Background: Insertable cardiac monitors (ICMs) are increasingly used to evaluate the atrial fibrillation (AF) burden after catheter ablation of AF. BioMonitor III (BM3) is an ICM with a long sensing vector, which enhances sensing capabilities. The AF detection algorithm of the BM3 is based on R–R interval variability. Objective: To evaluate the performance of the AF detection algorithm of BM3 in patients before and after catheter ablation of AF using simultaneous Holter recordings. Methods: In this prospective study, we enrolled patients scheduled for catheter ablation of paroxysmal or persistent AF. After BM3 implantation, patients had a 4 days Holter registration before and 3 months after ablation. All true AF episodes ≥2 min on the Holter were annotated and matched with BM3 detected AF detections. Results: Thirty-one patients were enrolled (mean age 60 ± 8, 74% male, 68% paroxysmal AF). Fifty-six Holter registrations were performed in 30 patients. Twelve patients demonstrated at least one true AF episode with a total AF duration of 570 h. The AF burden accuracy of BM3 before catheter ablation was 99.6%, with a duration sensitivity of 98.6% and a duration specificity of 99.9%. The AF burden accuracy of BM3 after catheter ablation was 99.8%, with a duration sensitivity of 90.2% and a duration specificity of 99.9%. Overall, the AF burden detected on the Holter and BM3 demonstrated a high Pearson correlation coefficient of 0.996. Conclusion: BM3 accurately detects AF burden in patients before and after catheter ablation of AF

    Electrographic flow mapping guided catheter ablation offers advantages for patients with persistent atrial fibrillation

    Get PDF
    Background: Catheter ablation (CA) remains challenging due to suboptimal success rates in persistent atrial fibrillation (AF). Existing mapping technologies cannot reliably distinguish sources in this patient population. Recently, the novel electrographic flow (EGF) mapping system was developed using a modified Horn-Schunk optical flow algorithm to detect and quantify patterns of electrical wavefront propagation in the atria. Objectives: To test the hypothesis that targeted source ablation based on EGF mapping is superior to empiric AF ablation. Methods: We included all consecutive patients undergoing EGF guided ablation for persistent AF. All patients underwent pulmonary vein isolation (PVI) and were treated with the same EAM system (CARTO). The outcome of PVI+EGF guided CA was compared with data of PVI-only procedures (PVI-only group) and PVI plus additional empiric adjunctive linear and substrate ablations (PVI+LINES group). 12-months outcome as freedom from AF and atrial tachycardia/flutter (AT/AFL), procedural safety and efficiency characterized by procedure duration, fluoroscopy use, radiofrequency applications and duration, were analyzed. Both intention-to-treat and per protocol analysis were conducted. Results: A total number of 70 patients (39 in PVI+EGF, 16 in PVI-only and 15 patients in PVI+LINES group) were enrolled. Intention-to-treat analysis showed fewer AF recurrences in PVI+EGF as compared with the PVI-only or PVI+LINES groups at 12 months (25.6% vs. 62.5% vs. 53.3%, p =.02). There were no differences in AT/AFL recurrence (17.9% vs. 37.5% vs. 20.0%, p =.37). Procedure times were longer in PVI+EGF group (p <.01), and there were no differences in fluoroscopy use (p =.67). Conclusion: Our data suggest that patients treated with EGF-guided CA developed fewer AF recurrences. Although the procedure times are longer, it seems to be safe and offers a more targeted, patient-specific ablation strategy beyond PVI than adjunctive empiric lines and substrate ablation in this complex group of patients

    Reducing radiation exposure in second-generation cryoballoon ablation without compromising clinical outcome

    Get PDF
    Purpose: Pulmonary vein isolation (PVI) using cryoballoon (CB) ablation is associated with an increased radiation exposure compared with radiofrequency ablation. Previous studies showed that radiation exposure in CB PVI can be reduced by optimizing the fluoroscopy protocol without comprising acute efficacy and safety. We evaluated the mid-term outcome of a modified fluoroscopy protocol in patients undergoing CB PVI. Methods: The study population comprised 90 consecutive patients who underwent second-generation CB-based PVI. The first 46 patients underwent CB PVI with conventional fluoroscopy settings (group A, historic control group). In the following 44 patients (group B), a modified fluoroscopy protocol was applied consisting of (1) visualization of degree of PV occlusion only by fluoroscopy (no cine runs); (2) increased radiation awareness. Primary endpoints were the total dose area product (DAP), fluoroscopy time, and freedom from documented recurrence of atrial fibrillation (AF) after a single procedure. Results: Group B had a lower median DAP (1393 cGycm2 vs. 3232 cGycm2, P < 0.001) and median fluoroscopy time (20 min vs. 24 min, P < 0.001) as compared with group A. The 1-year freedom from documented recurrence of AF after a single procedure was similar among groups (74% in group A vs. 77% in group B, P = 0.71). There were no significant differences between both groups for the secondary endpoints, including procedure duration, proportion of patients with complete electrical isolation, and complications. Conclusion: Using a modified fluoroscopy protocol and increased radiation awareness, radiation exposure can be significantly reduced in CB PVI with a similar 1-year clinical outcome