    Inpatient treatment of acute diverticulitis between 2010 and 2021 – a German nationwide study about long‐term trends and effects of the SARS-CoV-2 pandemic

    Get PDF
    Aim The aims of this study were to analyse all hospitalizations for acute diverticulitis in Germany from 2010 to 2021 and to assess the effects of the first 2 years of the SARS-CoV-2 pandemic on hospitalizations for acute diverticulitis. Method Using data from the German Federal Statistical Office, we analysed fully anonymized healthcare data of hospitalizations and treatment regimens with acute diverticulitis as the main diagnosis between 2010 and 2021. Logistic regression analyses for in-hospital mortality were performed. Results A total of 608,162 hospitalizations were included. While the number of hospitalizations constantly increased until 2019 (+52.4%), a relative decrease of 10.1% was observed between 2019 and 2020, followed by stable numbers of hospitalizations in 2021 (+1.1% compared with 2020). In-hospital mortality showed a relative decrease of 33.2% until 2019 and thereafter a relative increase of 26.9% in 2020 and of 7.5% in 2021. A 21.6% and a 19.3% drop in hospitalizations was observed during the first and second waves of the SARS-CoV-2 pandemic, mostly affecting hospitalizations for uncomplicated diverticulitis, with a corresponding 11.6% and 16.8% increase in admissions for complicated diverticulitis. Multivariable logistic regression analyses showed significantly higher in-hospital mortality for hospitalizations in which surgery (OR = 2.76) and CT (OR = 1.32) were given, as well as lower mortality for women (OR = 0.88), whereas percutaneous drainage was not associated with higher in-hospital mortality compared with conservative treatment (OR = 0.71). Conclusion This study points out the long-term trends in inpatient treatment for acute diverticulitis and the in-hospital mortality risk factors of patients hospitalized for acute diverticulitis in a large nationwide cohort, as well as changes in these trends and factors resulting from the SARS-CoV-2 pandemic. These changes might be attributable to delayed diagnosis and thus more severe stages of disease as a result of containment measures

    Coronary artery disease in patients hospitalized for peripheral artery disease: a nationwide analysis of 1.8 million patients

    Get PDF
    Purpose: Coronary artery disease (CAD) and peripheral artery disease (PAD) are highly prevalent in society. This nationwide analysis aimed to evaluate the trends of in-hospital treatment of patients admitted due to PAD with and without concomitant CAD, to determine the prevalence and risk factors of concomitant CAD in patients with PAD. Methods: Using data from the German Federal Statistical Office, we included all admissions for PAD (with and without concomitant CAD) in Germany between 2009 and 2018. Baseline patient characteristics, outcomes and comorbidities were analyzed. Elixhauser comorbidity groups and the linear van Walraven comorbidity score (vWs) were calculated to assess the comorbidity burden. Results: Of all 1,793,517 patients hospitalized for PAD, a total of 21.8% (390,259) had concomitant CAD, increasing from 18.6% in 2009 to 24.4% in 2018. Patients with accompanying CAD showed higher in-hospital mortality (3.7 vs. 2.6%), more major amputations (9.0 vs. 7.7%) and more comorbidities (Elixhauser score: 4.2 vs. 3.2 and vWs: 9.1 vs. 6.1), resulting in higher costs (median: EUR 4541 vs. EUR 4268 per case). More advanced stages of PAD were associated with multi-vessel CAD (10% of all patients with PAD Fontaine IV showed 3-vessel CAD) and the prevalence of multi-vessel CAD increased predominantly in patients with advanced PAD. Conclusion: One in four patients hospitalized for PAD had concomitant CAD, showing an increase over time with an additional medical and economic burden for hospitals compared with patients without CAD

    Evaluation of ECG-gated, high-pitch thoracoabdominal angiographies with dual-source photon-counting detector computed tomography

    Get PDF
    Purpose: The aim of this study was to evaluate the radiation dose, image quality, and the potential of virtual monoenergetic imaging (VMI) reconstructions of high-pitch computed tomography angiography (CTA) of the thoracoabdominal aorta on a dual-source photon-counting detector–CT (PCD-CT) in comparison with an energy-integrating detector–CT (EID-CT), with a special focus on low-contrast attenuation. Methods: Consecutive patients being referred for an electrocardiogram (ECG)-gated, high-pitch CTA of the thoracoabdominal aorta prior to transcatheter aortic valve replacement (TAVR), and examined on the PCD-CT, were included in this prospective single-center study. For comparison, a retrospective patient group with ECG-gated, high-pitch CTA examinations of the thoracoabdominal aorta on EID-CT with a comparable scan protocol was matched for gender, body mass index, height, and age. Virtual monoenergetic imaging reconstructions from 40 to 120 keV were performed. Enhancement and noise were measured in 7 vascular segments and the surrounding air as mean and standard deviation of CT values. The radiation dose was noted and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Finally, a subgroup analysis was performed, comparing VMI reconstructions from 40 keV to 70 keV in patients with at least a 50% decrease in contrast attenuation between the ascending aorta and femoral arteries. Results: Fifty patients (mean age 77.0±14.5 years; 31 women) were included. The radiation dose was significantly lower on the PCD-CT (4.2±1.4 vs. 7.2±2.2 mGy; p<0.001). With increasing keV, vascular noise, SNR, and CNR decreased. Intravascular attenuation was significantly higher on VMI at levels from 40 to 65, compared with levels of 120 keV (p<0.01 and p<0.005, respectively). On the PCD-CT, SNR was significantly higher in keV levels 40 and 70 (all p<0.001), and CNR was higher at keV levels 40 and 45 (each p<0.001), compared with scans on the EID-CT. At VMI ≤60 keV, image noise was also significantly higher than that in the control group. The subgroup analysis showed a drastically improved diagnostic performance of the low-keV images in patients with low-contrast attenuation. Conclusion: The ECG-gated CTA of the thoracoabdominal aorta in high-pitch mode on PCD-CT have significantly lower radiation dose and higher objective image quality than EID-CT. In addition, low-keV VMI can salvage suboptimal contrast studies, further reducing radiation dose by eliminating the need for repeat scans. Clinical Impact ECG-gated CT-angiographies of the thoracoabdominal aorta can be acquired with a lower radtiation dose and a better image quality by using a dual-source photon-countinge detector CT. Furthermore, the inherent spectral data offers the possiblity to improve undiagnostic images and thus saves the patient from further radiation and contrast application

    German nation-wide in-patient treatment of abdominal aortic aneurysm — trends between 2005 and 2019 and impact of the SARS-CoV-2 pandemic

    Get PDF
    Purpose Aim of this study was to analyze hospitalizations due to ruptured and non-ruptured abdominal aortic aneurysms (rAAA, nrAAA) in Germany between 2005 and 2021 to determine long-term trends in treatment and the impact of the SARS-CoV-2 pandemic. Materials and Methods Fully anonymized data were available from the research data center (RDC) of the German Federal Statistical Office (Destatis). All German hospitalizations with the ICD-10 code “I71.3, rAAA” and “I71.4, nrAAA” in 2005 and 2010–2021 were analyzed. Results We report data of a total of 202,951 hospitalizations. The number of hospitalizations increased from 2005 to 2019 (14,075 to 16,051, + 14.0%). The rate of open repair (OR) constantly decreased, whereas the rate of endovascular aortic repair (EVAR) increased until 2019. During the pandemic, the number of hospitalizations due to nrAAA dropped from 13,887 (86.5%) in 2019 to 11,278 (85.0%) in 2021. The strongest decrease of hospitalizations for AAA was observed during the first wave of the SARS-CoV-2-pandemic in spring 2020 (-25.5%). Conclusion Over the past decades, we observed an increasing number of hospitalizations due to AAA accompanied by a shift from OR to EVAR especially for nrAAA. During the lockdown measures due to the SARS-CoV-2-pandemic, a decrease in hospitalizations for nrAAA (but not for rAAA) was shown in 2020 and furthermore in 2021 with no rebound of treatment of nrAAA suggesting an accumulation of untreated AAA with a potentially increased risk of rupture

    Visualization of bone details in a novel photon-counting dual-source CT scanner—comparison with energy-integrating CT

    Get PDF
    OBJECTIVES: Photon-counting detector CT (PCD-CT) promises a leap in spatial resolution due to smaller detector pixel sizes than implemented in energy-integrating detector CTs (EID-CT). Our objective was to compare the visualization of smallest bone details between PCD-CT and EID-CT using a mouse as a specimen. MATERIALS AND METHODS: Two euthanized mice were scanned at a 20-slice EID-CT and a dual-source PCD-CT in single-pixel mode at various CTDI(Vol) values. Image noise and signal-to-noise ratio (SNR) were evaluated using repeated ROI measurements. Edge sharpness of bones was compared by the maximal slope within CT value plots along sampling lines intersecting predefined bones of the spine. Two readers evaluated bone detail visualization at four regions of the spine on a three-point Likert scale at various CTDI(Vol)’s. Two radiologists selected the series with better detail visualization among each of 20 SNR-matched pairs of EID-CT and PCD-CT series. RESULTS: In CTDI(Vol)-matched scans, PCD-CT series showed significantly lower image noise (Noise(CTDI=5 mGy): 16.27 ± 1.39 vs. 23.46 ± 0.96 HU, p < 0.01), higher SNR (SNR(CTDI=5 mGy): 20.57 ± 1.89 vs. 14.00 ± 0.66, p < 0.01), and higher edge sharpness (Edge Slope(lumbar spine): 981 ± 160 vs. 608 ± 146 HU/mm, p < 0.01) than EID-CT series. Two radiologists considered the delineation of bone details as feasible at consistently lower CTDI(Vol) values at PCD-CT than at EID-CT. In comparison of SNR-matched reconstructions, PCD-CT series were still considered superior in almost all cases. CONCLUSIONS: In this head-to-head comparison, PCD-CT showed superior objective and subjective image quality characteristics over EID-CT for the delineation of tiniest bone details. Even in SNR-matched pairs (acquired at different CTDI(Vol)’s), PCD-CT was strongly preferred by radiologists. KEY POINTS: • In dose-matched scans, photon-counting detector CT series showed significantly less image noise, higher signal-to-noise ratio, and higher edge sharpness than energy-integrating detector CT series. • Human observers considered the delineation of tiny bone details as feasible at much lower dose levels in photon-counting detector CT than in energy-integrating detector CT. • In direct comparison of series matched for signal-to-noise ratio, photon-counting detector CT series were considered superior in almost all cases. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00330-021-08441-4

    Optimal conspicuity of pancreatic ductal adenocarcinoma in virtual monochromatic imaging reconstructions on a photon-counting detector CT: comparison to conventional MDCT

    Get PDF
    Purpose To analyze the conspicuity of pancreatic ductal adenocarcinoma (PDAC) in virtual monoenergetic images (VMI) on a novel photon-counting detector CT (PCD-CT) in comparison to energy-integrating CT (EID-CT). Methods Inclusion criteria comprised initial diagnosis of PDAC (reference standard: histopathological analysis) and standardized contrast-enhanced CT imaging either on an EID-CT or a PCD-CT. Patients were excluded due to different histopathological diagnosis or missing tumor delineation on CT. On the PCD-CT, 40–190 keV VMI reconstructions were generated. Image noise, tumor-to-pancreas ratio (TPR) and contrast-to-noise ratio (CNR) were analyzed by ROI-based measurements in arterial and portal venous contrast phase. Two board-certified radiologist evaluated image quality and tumor delineation at both, EID-CT and PCD-CT (40 and 70 keV). Results Thirty-eight patients (mean age 70.4 years ± 10.3 [range 45–91], 27 males; PCD-CT: n=19, EID-CT: n=19) were retrospectively included. On the PCD-CT, tumor conspicuity (reflected by low TPR and high CNR) was significantly improved at low-energy VMI series (≤ 70 keV compared to > 70 keV), both in arterial and in portal venous contrast phase (P < 0.001), reaching the maximum at 40 keV. Comparison between PCD-CT and EID-CT showed significantly higher CNR on the PCD-CT in portal venous contrast phase at < 70 keV (P < 0.016). On the PCD-CT, tumor conspicuity was improved in portal venous contrast phase compared to arterial contrast phase especially at the lower end of the VMI spectrum (≤ 70 keV). Qualitative analysis revealed that tumor delineation is improved in 40 keV reconstructions compared to 70 keV reconstructions on a PCD-CT. Conclusion PCD-CT VMI reconstructions (≤ 70 keV) showed significantly improved conspicuity of PDAC in quantitative and qualitative analysis in both, arterial and portal venous contrast phase, compared to EID-CT, which may be important for early detection of tumor tissue in clinical routine. Tumor delineation was superior in portal venous contrast phase compared to arterial contrast phase

    Age-adjusted Charlson comorbidity index in recurrent glioblastoma: a new prognostic factor?

    Get PDF
    BACKGROUND: For recurrent glioblastoma (GB) patients, several therapy options have been established over the last years such as more aggressive surgery, re-irradiation or chemotherapy. Age and the Karnofsky Performance Status Scale (KPSS) are used to make decisions for these patients as these are established as prognostic factors in the initial diagnosis of GB. This study’s aim was to evaluate preoperative patient comorbidities by using the age-adjusted Charlson Comorbidity Index (ACCI) as a prognostic factor for recurrent GB patients. METHODS: In this retrospective analysis we could include 123 patients with surgery for primary recurrence of GB from January 2007 until December 2016 (43 females, 80 males, mean age 57 years (range 21–80 years)). Preoperative age, sex, ACCI, KPSS and adjuvant treatment regimes were recorded for each patient. Extent of resection (EOR) was recorded as a complete/incomplete resection of the contrast-enhancing tumor part. RESULTS: Median overall survival (OS) was 9.0 months (95% CI 7.1–10.9 months) after first re-resection. Preoperative KPSS > 80% (P < 0.001) and EOR (P = 0.013) were associated with significantly improved survival in univariate analysis. Including these factors in multivariate analysis, preoperative KPSS < 80 (HR 2.002 [95% CI: 1.246–3.216], P = 0.004) and EOR are the only significant prognostic factor (HR 1.611 [95% CI: 1.036–2.505], P = 0.034). ACCI was not shown as a prognostic factor in univariate and multivariate analyses. CONCLUSION: For patients with surgery for recurrent glioblastoma, the ACCI does not add further information about patient’s prognosis besides the well-established KPSS and extent of resection

    Radiomics signature for automatic hydronephrosis detection in unenhanced low-dose CT

    Get PDF
    Purpose To investigate the diagnostic performance of an automatic pipeline for detection of hydronephrosis on kidneýs parenchyma on unenhanced low-dose CT of the abdomen. Methods This retrospective study included 95 patients with confirmed unilateral hydronephrosis in an unenhanced low-dose CT of the abdomen. Data were split into training (n = 67) and test (n = 28) cohorts. Both kidneys for each case were included in further analyses, whereas the kidney without hydronephrosis was used as control. Using the training cohort, we developed a pipeline consisting of a deep-learning model for automatic segmentation (a Convolutional Neural Network based on nnU-Net architecture) of the kidneýs parenchyma and a radiomics classifier to detect hydronephrosis. The models were assessed using standard classification metrics, such as area under the ROC curve (AUC), sensitivity and specificity, as well as semantic segmentation metrics, including Dice coefficient and Jaccard index. Results Using manual segmentation of the kidney’s parenchyma, hydronephrosis can be detected with an AUC of 0.84, a sensitivity of 75% and a specificity of 82%, a PPV of 81% and a NPV of 77%. Automatic kidney segmentation achieved a mean Dice score of 0.87 and 0.91 for the right and left kidney, respectively. Additionally, automatic segmentation achieved an AUC of 0.83, a sensitivity of 86%, specificity of 64%, PPV of 71%, and NPV of 82%. Conclusion Our proposed radiomics signature using automatic kidneýs parenchyma segmentation allows for accurate hydronephrosis detection on unenhanced low-dose CT scans of the abdomen independently of widened renal pelvis. This method could be used in clinical routine to highlight hydronephrosis to radiologists as well as clinicians, especially in patients with concurrent parapelvic cysts and might reduce time and costs associated with diagnosing hydronephrosis

    Virtual non-contrast reconstructions of photon-counting detector CT angiography datasets as substitutes for true non-contrast acquisitions in patients after EVAR—performance of a novel calcium-preserving reconstruction algorithm

    Get PDF
    The purpose of this study was to evaluate virtual-non contrast reconstructions of Photon-Counting Detector (PCD) CT-angiography datasets using a novel calcium-preserving algorithm (VNC(PC)) vs. the standard algorithm (VNC(Conv)) for their potential to replace unenhanced acquisitions (TNC) in patients after endovascular aneurysm repair (EVAR). 20 EVAR patients who had undergone CTA (unenhanced and arterial phase) on a novel PCD-CT were included. VNC(Conv)- and VNC(PC)-series were derived from CTA-datasets and intraluminal signal and noise compared. Three readers evaluated image quality, contrast removal, and removal of calcifications/stent parts and assessed all VNC-series for their suitability to replace TNC-series. Image noise was higher in VNC- than in TNC-series (18.6 ± 5.3 HU, 16.7 ± 7.1 HU, and 14.9 ± 7.1 HU for VNC(Conv)-, VNC(PC)-, and TNC-series, p = 0.006). Subjective image quality was substantially higher in VNC(PC)- than VNC(Conv)-series (4.2 ± 0.9 vs. 2.5 ± 0.6; p < 0.001). Aortic contrast removal was complete in all VNC-series. Unlike in VNC(Conv)-reconstructions, only minuscule parts of stents or calcifications were erroneously subtracted in VNC(PC)-reconstructions. Readers considered 95% of VNC(PC)-series fully or mostly suited to replace TNC-series; for VNC(Conv)-reconstructions, however, only 75% were considered mostly (and none fully) suited for TNC-replacement. VNC(PC)-reconstructions of PCD-CT-angiography datasets have excellent image quality with complete contrast removal and only minimal erroneous subtractions of stent parts/calcifications. They could replace TNC-series in almost all cases

    Optimal conspicuity of liver metastases in virtual monochromatic imaging reconstructions on a novel photon-counting detector CT—effect of keV settings and BMI

    Get PDF
    In dual-energy CT datasets, the conspicuity of liver metastases can be enhanced by virtual monoenergetic imaging (VMI) reconstructions at low keV levels. Our study investigated whether this effect can be reproduced in photon-counting detector CT (PCD-CT) datasets. We analyzed 100 patients with liver metastases who had undergone contrast-enhanced CT of the abdomen on a PCD-CT (n = 50) or energy-integrating detector CT (EID-CT, single-energy mode, n = 50). PCD-VMI-reconstructions were performed at various keV levels. Identical regions of interest were positioned in metastases, normal liver, and other defined locations assessing image noise, tumor-to-liver ratio (TLR), and contrast-to-noise ratio (CNR). Patients were compared inter-individually. Subgroup analyses were performed according to BMI. On the PCD-CT, noise and CNR peaked at the low end of the keV spectrum. In comparison with the EID-CT, PCD-VMI-reconstructions exhibited lower image noise (at 70 keV) but higher CNR (for ≤70 keV), despite similar CTDIs. Comparing high- and low-BMI patients, CTDI-upregulation was more modest for the PCD-CT but still resulted in similar noise levels and preserved CNR, unlike the EID-CT. In conclusion, PCD-CT VMIs in oncologic patients demonstrated reduced image noise–compared to a standard EID-CT–and improved conspicuity of hypovascularized liver metastases at low keV values. Patients with higher BMIs especially benefited from constant image noise and preservation of lesion conspicuity, despite a more moderate upregulation of CTDI