735 research outputs found
Deep MERLIN 5GHz Radio Imaging of Supernova Remnants in the M82 Starburst
The results of an extremely deep, 8-day long observation of the central kpc
of the nearby starburst galaxy M82 using MERLIN (Multi-Element Radio Linked
Interferometer Network) at 5 GHz are presented. The 17E-06 Jy/beam, rms noise
level in the naturally weighted image make it the most sensitive high
resolution radio image of M82 made to date. Over 50 discrete sources are
detected, the majority of which are supernova remnants, but with 13 identified
as HII regions. Sizes, flux densities and radio brightnesses are given for all
of the detected sources, which are all well resolved with a majority showing
shell or partial shell structures. Those sources within the sample which are
supernova remnants have diameters ranging from 0.3 to 6.7 pc, with a mean size
of 2.9 pc.
From a comparison with previous MERLIN 5 GHz observations made in July 1992,
which gives a 9.75 year timeline, it has been possible to measure the expansion
velocities of ten of the more compact sources, eight of which have not been
measured before. These derived expansion velocities range between 2200 and
10500 km/s.Comment: 34 pages, 10 figures. Accepted by MNRA
Second Epoch Global VLBI Observations of Compact Radio Sources in the M82 Starburst Galaxy
We have presented the results of a second epoch of global Very Long Baseline
Interferometry observations, taken on 23 February 2001 at a wavelength of 18
cm, of the central kiloparsec of the nearby starburst galaxy Messier 82. These
observations were aimed at studying the structural and flux evolution of some
of the compact radio sources in the central region that have been identified as
supernova remnants. The objects 41.95+575 and 43.31+592 have been studied,
expansion velocities of 2500 +/- 1200 km/s and 7350 +/- 2100 km/s respectively
have been derived. Flux densities of 31.1 +/- 0.3 mJy and 17.4 +/- 0.3 mJy have
been measured for the two objects. These results are consistent with
measurements and predictions from previous epochs.Comment: 5 pages, 3 figures. To be published on the accompanying CD of the
Proceedings of IAU Colloquium 192: Supernova
Tests of star formation metrics in the low metallicity galaxy NGC 5253 using ALMA observations of H30 line emission
We use Atacama Large Millimeter/submillimeter Array (ALMA) observations of
H30 (231.90 GHz) emission from the low metallicity dwarf galaxy NGC
5253 to measure the star formation rate (SFR) within the galaxy and to test the
reliability of SFRs derived from other commonly-used metrics. The H30
emission, which originates mainly from the central starburst, yields a
photoionizing photon production rate of (1.90.3)10 s
and an SFR of 0.0870.013 M yr based on conversions that
account for the low metallicity of the galaxy and for stellar rotation. Among
the other star formation metrics we examined, the SFR calculated from the total
infrared flux was statistically equivalent to the values from the H30
data. The SFR based on previously-published versions of the H flux that
were extinction corrected using Pa and Pa lines were lower than
but also statistically similar to the H30 value. The mid-infrared (22
m) flux density and the composite star formation tracer based on H
and mid-infrared emission give SFRs that were significantly higher because the
dust emission appears unusually hot compared to typical spiral galaxies.
Conversely, the 70 and 160 m flux densities yielded SFR lower than the
H30 value, although the SFRs from the 70 m and H30 data
were within 1-2 of each other. While further analysis on a broader
range of galaxies are needed, these results are instructive of the best and
worst methods to use when measuring SFR in low metallicity dwarf galaxies like
NGC 5253.Comment: 14 pages, 5 figures, accepted for publication in MNRA
15 years of VLBI observations of two compact radio sources in Messier 82
We present the results of a second epoch of 18cm global Very Long-Baseline
Interferometry (VLBI) observations, taken on 23 February 2001, of the central
kiloparsec of the nearby starburst galaxy Messier 82. These observations
further investigate the structural and flux evolution of the most compact radio
sources in the central region of M82. The two most compact radio objects in M82
have been investigated (41.95+575 and 43.31+592). Using this recent epoch of
data in comparison with our previous global VLBI observations and two earlier
epochs of European VLBI Network observations we measure expansion velocities in
the range of 1500-2000km/s for 41.95+575, and 9000-11000km/s for 43.31+592
using various independent methods. In each case the measured remnant expansion
velocities are significantly larger than the canonical expansion velocity
(500km/s) of supernova remnants within M82 predicted from theoretical models.
In this paper we discuss the implications of these measured expansion
velocities with respect to the high density environment that the SNR are
expected to reside in within the centre of the M82 starburst.Comment: Accepted for publication in MNRAS, 9 pages, 8 figure
OH masers in nearby galaxies
Using the VLA, a series of high velocity resolution observations have been made of the M82 starburst. These observations follow up on previous studies of the main line OH maser emission in the central kiloparsec of this starburst region, but with greater velocity resolution than previous observations. A total of thirteen masers were detected, including all but one of the previously known sources. These new results clearly show velocity structure in spectra from several of the maser regions. Position-velocity plots show good agreement with the distribution of HI including interesting velocity structure on the blue-ward feature in the west of the starburst which traces the velocity distribution seen in the ionised gas as traced by [NeII] for example
Deep Space Network information system architecture study
The purpose of this article is to describe an architecture for the Deep Space Network (DSN) information system in the years 2000-2010 and to provide guidelines for its evolution during the 1990s. The study scope is defined to be from the front-end areas at the antennas to the end users (spacecraft teams, principal investigators, archival storage systems, and non-NASA partners). The architectural vision provides guidance for major DSN implementation efforts during the next decade. A strong motivation for the study is an expected dramatic improvement in information-systems technologies, such as the following: computer processing, automation technology (including knowledge-based systems), networking and data transport, software and hardware engineering, and human-interface technology. The proposed Ground Information System has the following major features: unified architecture from the front-end area to the end user; open-systems standards to achieve interoperability; DSN production of level 0 data; delivery of level 0 data from the Deep Space Communications Complex, if desired; dedicated telemetry processors for each receiver; security against unauthorized access and errors; and highly automated monitor and control
Nowhere to Hide: Radio-faint AGN in the GOODS-N field. I. Initial catalogue and radio properties
(Abridged) Conventional radio surveys of deep fields ordinarily have
arc-second scale resolutions often insufficient to reliably separate radio
emission in distant galaxies originating from star-formation and AGN-related
activity. Very long baseline interferometry (VLBI) can offer a solution by
identifying only the most compact radio emitting regions in galaxies at
cosmological distances where the high brightness temperatures (in excess of
K) can only be reliably attributed to AGN activity. We present the first
in a series of papers exploring the faint compact radio population using a new
wide-field VLBI survey of the GOODS-N field. The unparalleled sensitivity of
the European VLBI Network (EVN) will probe a luminosity range rarely seen in
deep wide-field VLBI observations, thus providing insights into the role of AGN
to radio luminosities of the order across cosmic
time. The newest VLBI techniques are used to completely cover an entire 7'.5
radius area to milliarcsecond resolutions, while bright radio sources ( mJy) are targeted up to 25 arcmin from the pointing centre. Multi-source
self-calibration, and a primary beam model for the EVN array are used to
correct for residual phase errors and primary beam attenuation respectively.
This paper presents the largest catalogue of VLBI detected sources in GOODS-N
comprising of 31 compact radio sources across a redshift range of 0.11-3.44,
almost three times more than previous VLBI surveys in this field. We provide a
machine-readable catalogue and introduce the radio properties of the detected
sources using complementary data from the e-MERLIN Galaxy Evolution survey
(eMERGE).Comment: 15 pages, 8 figures, accepted in A&A. Machine-readable table
available upon reques
Patient-Related Risk Factors for Periprosthetic Joint Infection after Total Joint Arthroplasty:A Systematic Review and Meta-Analysis
<div><p>Background</p><p>Periprosthetic joint infections (PJIs) are dreaded complications of total joint arthroplasties. The risk of developing PJIs is likely to be influenced by several patient factors such as sociodemographic characteristics, body mass index (BMI), and medical and surgical histories. However, the nature and magnitude of the long-term longitudinal associations between these patient-related factors and risk of developing PJIs are uncertain.</p><p>Objective</p><p>To conduct a systematic review and meta-analysis to assess the associations between several patient-related factors and PJI.</p><p>Data Sources</p><p>MEDLINE, EMBASE, Web of Science, Cochrane Library, and reference lists of relevant studies from inception to September 2015.</p><p>Study Selection</p><p>Longitudinal studies with at least one-year of follow-up for PJIs after total joint arthroplasty.</p><p>Data Extraction and Synthesis</p><p>Two investigators extracted data on study characteristics, methods, and outcomes. A consensus was reached with involvement of a third. The relative risk (RR) with 95% confidence intervals was used as the summary measure of association across studies. Study-specific RRs with 95% confidence intervals were meta-analysed using random effect models and were grouped by study-level characteristics.</p><p>Results</p><p>Sixty-six observational (23 prospective cohort and 43 retrospective cohort or case-control) studies with data on 512,508 participants were included. Comparing males to females and smokers to non-smokers, the pooled RRs for PJI were 1.36 (1.18–1.57) and 1.83 (1.24–2.70) respectively. There was no evidence of any significant associations of PJI with age and high alcohol intake. Comparing BMI ≥ 30 versus < 30 kg/m<sup>2</sup>; ≥ 35 versus < 35 kg/m<sup>2</sup>; and ≥ 40 versus < 40 kg/m<sup>2</sup>; the pooled RRs were 1.60 (1.29–1.99); 1.53 (1.22–1.92); and 3.68 (2.25–6.01) respectively. Histories of diabetes, rheumatoid arthritis, depression, steroid use, and previous joint surgery were also associated with increased risk of PJI. The results remained similar when grouped by relevant study level characteristics.</p><p>Conclusions</p><p>Several potentially modifiable patient-related factors are associated with the risk of developing PJIs. Identifying patients with these risk factors who are due to have arthroplasty surgery and modulating these risk factors might be essential in reducing the incidence of PJI. Further research is however warranted to assess the potential clinical utility of these risk factors as risk assessment tools for PJI.</p><p>Systematic Review Registration</p><p>PROSPERO 2015: CRD42015023485</p></div
Re-Infection Outcomes Following One- And Two-Stage Surgical Revision of Infected Knee Prosthesis:A Systematic Review and Meta-Analysis
BACKGROUND:Periprosthetic joint infection (PJI) is a serious complication of total knee arthroplasty. Two-stage revision is the most widely used technique and considered as the most effective for treating periprosthetic knee infection. The one-stage revision strategy is an emerging alternative option, however, its performance in comparison to the two-stage strategy is unclear. We therefore sought to ask if there was a difference in re-infection rates and other clinical outcomes when comparing the one-stage to the two-stage revision strategy. OBJECTIVE:Our first objective was to compare re-infection (new and recurrent infections) rates for one- and two-stage revision surgery for periprosthetic knee infection. Our second objective was to compare between the two revision strategies, clinical outcomes as measured by postoperative Knee Society Knee score, Knee Society Function score, Hospital for Special Surgery knee score, WOMAC score, and range of motion. DESIGN:Systematic review and meta-analysis. DATA SOURCES:MEDLINE, EMBASE, Web of Science, Cochrane Library, reference lists of relevant studies to August 2015, and correspondence with investigators. STUDY SELECTION:Longitudinal (prospective or retrospective cohort) studies conducted in generally unselected patients with periprosthetic knee infection treated exclusively by one- or two-stage revision and with re-infection outcomes reported within two years of revision surgery. No clinical trials comparing both revision strategies were identified. REVIEW METHODS:Two independent investigators extracted data and discrepancies were resolved by consensus with a third investigator. Re-infection rates from 10 one-stage studies (423 participants) and 108 two-stage studies (5,129 participants) were meta-analysed using random-effect models after arcsine transformation. RESULTS:The rate (95% confidence intervals) of re-infection was 7.6% (3.4-13.1) in one-stage studies. The corresponding re-infection rate for two-stage revision was 8.8% (7.2-10.6). In subgroup analyses, re-infection rates remained generally similar for several study-level and clinically relevant characteristics. Postoperative clinical outcomes of knee scores and range of motion were similar for both revision strategies. LIMITATIONS:Potential bias owing to the limited number of one-stage revision studies and inability to explore heterogeneity in greater detail. CONCLUSIONS:Available evidence from aggregate published data suggest the one-stage revision strategy may be as effective as the two-stage revision strategy in treating infected knee prostheses in generally unselected patients. Further investigation is warranted. SYSTEMATIC REVIEW REGISTRATION:PROSPERO 2015: CRD42015017327
- …