16 research outputs found
New insight of CMR in the diagnosis of left ventricular non-compaction: measurement of trabeculated left ventricular mass
MRI investigation of granular interface rheology using a new cylinder shear apparatus
The rheology of granular materials near an interface is investigated through
proton magnetic resonance imaging. A new cylinder shear apparatus has been
inserted in the MRI device, which allows the control of the radial confining
pressure exerted by the outer wall on the grains and the measurement of the
torque on the inner shearing cylinder. A multi-layer velocimetry sequence has
been developed for the simultaneous measurement of velocity profiles in
different sample zones, while the measurement of the solid fraction profile is
based on static imaging of the sample. This study describes the influence of
the roughness of the shearing interface and of the transverse confining walls
on the granular interface rheology
Shear thickening regimes of dense non-Brownian suspensions
We propose a unifying rheological framework for dense suspensions of
non-Brownian spheres, predicting the onsets of particle friction and particle
inertia as distinct shear thickening mechanisms, while capturing quasistatic
and soft particle rheology at high volume fractions and shear rates
respectively. Discrete element method simulations that take suitable account of
hydrodynamic and particle-contact interactions corroborate the model
predictions, demonstrating both mechanisms of shear thickening, and showing
that they can occur concurrently with carefully selected particle surface
properties under certain flow conditions. Microstructural transitions
associated with frictional shear thickening are presented. We find very
distinctive divergences of both the microstructural and dynamic variables with
respect to volume fraction in the thickened and non-thickened states
Linking particle properties to dense suspension extrusion flow characteristics using discrete element simulations
Extrusion is a widely used process for forming suspensions and pastes into designed shapes, and is central to the manufacture of many products. In this article, the extrusion through a square-entry die of non-Brownian spheres suspended in Newtonian fluid is investigated using discrete element simulations, capturing individual particle-particle contacts and hydrodynamic interactions. The simulations reveal inhomogeneous velocity and stress distributions, originating in the inherent microstructure formed by the constituent particles. Such features are shown to be relevant to generic paste extrusion behavior, such as extrudate swell. The pressure drop across the extruder is correlated with the extrudate flow rate, with the empirical fitting parameters being linked directly to particle properties such as surface friction, and processing conditions such as extruder wall roughness. Our model and results bring recent advances in suspension rheology into an industrial setting, laying foundations for future model development, predictive paste formulation and extrusion design. © 2016 American Institute of Chemical Engineers AIChE J, 63: 3069–3082, 201
Epidémiologie et évaluation de la prise en charge des dissections aortiques aiguës de type B sur l Ile de la Réunion
Cette étude a pour but de décrire la population des dissections aortiques aiguës de Type B à la Réunion et d évaluer leur prise en charge thérapeutique. Entre janvier 2009 et janvier 2013, 19 patients ont été sélectionnés présentant un diagnostic de dissection aortique aiguë de type B datant de moins de quinze jours, confirmé par angio-TDM et pris en charge par l USIC au CHU Félix Guyon à la Réunion. Notre population était constituée d une population très jeune (moyenne=56 ans vs 66,3 ans pour l IRAD, p=0.001) sans antécédent de pathologie tissulaire (0% versus 1.8% pour l IRAD) avec une prédominance masculine (63%, p=0.59) et une forte prévalence de l hypertension artérielle (95% versus 76.6% pour l IRAD, p=0.008) et du diabète (21% versus 6.6% pour l IRAD, p=0.004). La mortalité était plus marquée (21% versus 13% pour l IRAD, p=0.29) dans cette cohorte constituée de 47% de dissections aortiques compliquées, 31% de dissections aortiques non compliquées avec des critères de gravité et 22% de dissections aortiques non compliquées sans critère de gravité. Nous observons une non-utilisation des bétabloquants en intraveineux (0% vs 78% pour l IRAD), avec des objectifs tensionnels trop peu respectés (58% à l USIC, 41% dans le service de cardiologie conventionnel). Alors que nous avons une bonne prise en charge de la douleur avec l utilisation de la morphine dans 37% des cas à l USIC. A la suite de cette étude, un protocole sera élaboré pour améliorer la prise en charge médicamenteuse et interventionnelle des dissections aortiques aiguës de type B, dont l objectif est de faire baisser la mortalité dans cette population à haut risque cardiovasculaire et non observante.BORDEAUX1-Bib.electronique (335229901) / SudocSudocFranceF