14 research outputs found

    Comparison of Howland and General Impedance Converter (GIC) circuit based current sources for bio-impedance measurements

    Get PDF
    The current source is a key component in bio-impedance measurement systems. The accuracy of the current source can be measured in terms of its output impedance together with other parameters, with certain applications demanding extremely high output impedance. This paper presents an investigation and comparison of different current source designs based on the Enhanced Howland circuit combined with a General Impedance Converter (GIC) circuit using both ideal and non-ideal operational amplifiers. Under differing load conditions two different settings of the GIC are evaluated and the results are compared to show its performance settings. Whilst the study has shown that over a wide bandwidth (i.e. 100Hz-100MHz) the output impedance is limited, operation over a more limited range offers output impedance in the Giga-ohm range, which can be considered as being infinite

    A Comprehensive Study on Current Source Circuits

    No full text

    This content has been downloaded from IOPscience. Please scroll down to see the full text. A comparison of modified Howland circuits as current generators with current mirror type circuits A comparison of modified Howland circuits as current generators wi

    No full text
    Abstract. Multi-frequency electrical impedance tomography (EIT) systems require stable voltage controlled current generators that will work over a wide frequency range and with a large variation in load impedance. In this paper we compare the performance of two commonly used designs: the first is a modified Howland circuit whilst the second is based on a current mirror. The output current and the output impedance of both circuits were determined through PSPICE simulation and through measurement. Both circuits were stable over the frequency ranges 1 kHz to 1 MHz. The maximum variation of output current with frequency for the modified Howland circuit was 2.0% and for the circuit based on a current mirror 1.6%. The output impedance for both circuits was greater than 100 k for frequencies up to 100 kHz. However, neither circuit achieved this output impedance at 1 MHz. Comparing the results from the two circuits suggests that there is little to choose between them in terms of a practical implementation

    Biomedical Control Interface for a Physical Rehabilitation Serious Game

    No full text

    Bipolar and tetrapolar transfer impedance measurements from volume conductor

    No full text
    corecore