5 research outputs found
Multi-messenger astronomy of gravitational-wave sources with flexible wide-area radio transient surveys
We explore opportunities for multi-messenger astronomy using gravitational
waves (GWs) and prompt, transient low-frequency radio emission to study highly
energetic astrophysical events. We review the literature on possible sources of
correlated emission of gravitational waves and radio transients, highlighting
proposed mechanisms that lead to a short-duration, high-flux radio pulse
originating from the merger of two neutron stars or from a superconducting
cosmic string cusp. We discuss the detection prospects for each of these
mechanisms by low-frequency dipole array instruments such as LWA1, LOFAR and
MWA. We find that a broad range of models may be tested by searching for radio
pulses that, when de-dispersed, are temporally and spatially coincident with a
LIGO/Virgo GW trigger within a \usim 30 second time window and \usim 200
\mendash 500 \punits{deg}^{2} sky region. We consider various possible
observing strategies and discuss their advantages and disadvantages. Uniquely,
for low-frequency radio arrays, dispersion can delay the radio pulse until
after low-latency GW data analysis has identified and reported an event
candidate, enabling a \emph{prompt} radio signal to be captured by a
deliberately targeted beam. If neutron star mergers do have detectable prompt
radio emissions, a coincident search with the GW detector network and
low-frequency radio arrays could increase the LIGO/Virgo effective search
volume by up to a factor of \usim 2. For some models, we also map the
parameter space that may be constrained by non-detections.Comment: 31 pages, 4 figure
Observations of Giant Pulses from Pulsar PSR B0950+08 using LWA1
We report the detection of giant pulse emission from PSR B0950+08 in 24 hours
of observations made at 39.4 MHz, with a bandwidth of 16 MHz, using the first
station of the Long Wavelength Array, LWA1. We detected 119 giant pulses from
PSR B0950+08 (at its dispersion measure), which we define as having SNRs at
least 10 times larger than for the mean pulse in our data set. These 119 pulses
are 0.035% of the total number of pulse periods in the 24 hours of
observations. The rate of giant pulses is about 5.0 per hour. The cumulative
distribution of pulse strength is a steep power law, , but much less steep than would be expected if we were observing the
tail of a Gaussian distribution of normal pulses. We detected no other
transient pulses in a dispersion measure range from 1 to 90 pc cm, in
the beam tracking PSR B0950+08. The giant pulses have a narrower temporal width
than the mean pulse (17.8 ms, on average, vs. 30.5 ms). The pulse widths are
consistent with a previously observed weak dependence on observing frequency,
which may be indicative of a deviation from a Kolmogorov spectrum of electron
density irregularities along the line of sight. The rate and strength of these
giant pulses is less than has been observed at 100 MHz. Additionally, the
mean (normal) pulse flux density we observed is less than at 100 MHz.
These results suggest this pulsar is weaker and produces less frequent giant
pulses at 39 MHz than at 100 MHz.Comment: 27 pages, 12 figures, typos correcte
Observations of Giant Pulses from Pulsar B0950+08 Using LWA1
We report the detection of giant pulse (GP) emission from PSR B0950+08 in 24 hours of observations made at 39.4 MHz, with a bandwidth of 16 MHz, using the first station of the Long Wavelength Array. We detected 119 GPs from PSR B0950+08 (at its dispersion measure (DM)), which we define as having a signal-to-noise ratio at least 10 times larger than for the mean pulse in our data set. These 119 pulses are 0.035% of the total number of pulse periods in the 24 hours of observations. The rate of GPs is about 5.0 per hour. The cumulative distribution of pulse strength S is a steep power law, _N(>S) ∝ S^(-4.7), but much less steep than would be expected if we were observing the tail of a Gaussian distribution of normal pulses. We detected no other transient pulses in a DM range from 1 to 90 pc cm^(−3), in the beam tracking PSR B0950+08. The GPs have a narrower temporal width than the mean pulse (17.8 ms, on average, versus 30.5 ms). The pulse widths are consistent with a previously observed weak dependence on observing frequency, which may be indicative of a deviation from a Kolmogorov spectrum of electron density irregularities along the line of sight. The rate and strength of these GPs is less than has been observed at ~100 MHz. Additionally, the mean (normal) pulse flux density we observed is less than at ~100 MHz. These results suggest this pulsar is weaker and produces less frequent GPs at 39 MHz than at 100 MHz