    The European Registry for Patients with Mechanical Circulatory Support of the European Association for Cardio-Thoracic Surgery:third report

    Get PDF
    OBJECTIVES: In the third report of the European Registry for Patients with Mechanical Circulatory Support of the European Association for Cardio-Thoracic Surgery, outcomes of patients receiving mechanical circulatory support are reviewed in relation to implant era. METHODS: Procedures in adult patients (January 2011-June 2020) were included. Patients from centres with 3 months). Risk factors for death were explored using univariable Cox regression with a stepwise time-varying hazard ratio (3 months). RESULTS: In total, 4834 procedures in 4486 individual patients (72 hospitals) were included, with a median follow-up of 1.1 (interquartile range: 0.3-2.6) years. The annual number of implants (range: 346-600) did not significantly change (P = 0.41). Both Interagency Registry for Mechanically Assisted Circulatory Support class (classes 4-7: 23, 25 and 33%; P 3 months: 0.45). Bilirubin and creatinine levels were significant risk factors in the early phase but not in the late phase after the implant. CONCLUSIONS: In its 10 years of existence, EUROMACS has become a point of reference enabling benchmarking and outcome monitoring. Patient characteristics and outcomes changed between implant eras. In addition, both occurrence of outcomes and risk factor weights are time dependent
    corecore