80 research outputs found
Polymer hernia repair materials: adapting to patient needs and surgical techniques
"Publicación presentada para convocatoria 2023 Proyectos Generación de Conocimiento"Biomaterials and their applications are perhaps among the most dynamic areas of research within the field of biomedicine. Any advance in this topic translates to an improved quality of life for recipient patients. One application of a biomaterial is the repair of an abdominal wall defect whether congenital or acquired. In the great majority of cases requiring surgery, the defect takes the form of a hernia. Over the past few years, biomaterials designed with this purpose in mind have been gradually evolving in parallel with new developments in the different surgical techniques. In consequence, the classic polymer prosthetic materials have been the starting point for structural modifications or new prototypes that have always strived to ccommodate patients? needs. This evolving process has pursued both improvements in the wound repair process depending on the implant interface in the host and in the material?s mechanical properties at the repair site. This last factor is important considering that this site?the abdominal wall?is a dynamic structure subjected to considerable mechanical demands. This review aims to provide a narrative overview of the different biomaterials that have been gradually introduced over the years, long with their modifications as new surgical techniques have unfolded
Efficacy of antimicrobial agents delivered to hernia meshes using an adaptable thermo-responsive hyaluronic acid-based coating
19 p.Purpose Mesh-related infection is a critical outcome for patients with hernia defect stabilized with synthetic or biological meshes. Even though bioactive meshes loaded with antibiotics or antiseptics are slowly emerging in the market, the available solutions still lack versatility. Here, we proposed a polymer solution, i.e., hyaluronic acid-poly(N-isopropylacrylamide) (HApN), which forms a hydrogel to be used as coating for meshes only when it reaches body temperature. Methods We assessed how the gelation of HApN was influenced by the incorporation of different antibiotic and antiseptic formulations, and how this gel can be used to coat several mesh types. The impact of the coating on the elastic behavior of a macroporous mesh was tested under cyclic elongation condition. Finally, we selected two different coating formulations, one based on antibiotics (gentamicin + rifampicin) and one based on antiseptic (chlorhexidine) and tested in vitro their antimicrobial efficacies. Results HApN can be used as carrier for different antimicrobial agents, without having a strong influence on its gelation behavior. Porous or dense meshes can be coated with this polymer, even though the stability was not optimal on macroporous meshes such as Optilene when pores are too large. HApN loaded with drugs inhibited in vitro the growth of several Gram-positive and Gram-negative bacteria. Conclusion Compared to the available technologies developed to endow meshes with antibacterial activity, the proposed HApN offers further versatility with potential to prevent mesh-related infection in hernioplasty.European Hernia SocietyMinisterio de Ciencia, Innovación y Universidade
New insights into the application of 3D-printing technology in hernia repair.
"Publicación presentada para sexenios"Abdominal hernia repair using prosthetic materials is among the surgical interventions most widely performed worldwide. These materials, or meshes, are implanted to close the hernial defect, reinforcing the abdominal muscles and reestablishing mechanical functionality of the wall. Meshes for hernia repair are made of synthetic or biological materials exhibiting multiple shapes and configurations. Despite the myriad of devices currently marketed, the search for the ideal mesh continues as, thus far, no device offers optimal tissue repair and restored mechanical performance while minimizing postoperative complications. Additive manufacturing, or 3D-printing, has great potential for biomedical applications. Over the years, different biomaterials with advanced features have been successfully manufactured via 3D-printing for the repair of hard and soft tissues. This technological improvement is of high clinical relevance and paves the way to produce next-generation devices tailored to suit each individual patient. This review focuses on the state of the art and applications of 3D-printing technology for the manufacture of synthetic meshes. We highlight the latest approaches aimed at developing improved bioactive materials (e.g., optimizing antibacterial performance, drug release, or device opacity for contrast imaging). Challenges, limitations, and future perspectives are discussed, offering a comprehensive scenario for the applicability of 3D-printing in hernia repair.Financial support from the CIBER-BB
Experimental study on the use of a chlorhexidine-loaded carboxymethylcellulose gel as antibacterial coating for hernia repair meshes
21 p.Purpose: Biomaterials with an antimicrobial coating could avoid mesh-associated infection following hernia repair. This study assesses the use of a chlorhexidine-loaded carboxymethylcellulose gel in a model of Staphylococcus aureus mesh infection. Methods: A 1% carboxymethylcellulose gel containing 0.05% chlorhexidine was prepared and tested in vitro and in vivo. The in vitro tests were antibacterial activity (S. aureus; agar diffusion test) and gel cytotoxicity compared to aqueous 0.05% chlorhexidine (fibroblasts; alamarBlue). For the in vivo study, partial abdominal wall defects (5 × 2 cm) were created in New Zealand white rabbits (n = 15) and inoculated with 0.25 mL of S. aureus ( 106 CFU/mL). Defects were repaired with a lightweight polypropylene mesh (Optilene) without coating (n = 3) or coated with a carboxymethylcellulose gel (n = 6) or chlorhexidine-loaded carboxymethylcellulose gel (n = 6). Fourteen days after surgery, bacterial adhesion to the implant (sonication, immunohistochemistry), host tissue incorporation (light microscopy) and macrophage reaction (immunohistochemistry) were examined. Results: Carboxymethylcellulose significantly reduced the toxicity of chlorhexidine (p < 0.001) without limiting its antibacterial activity. While control and gel-coated implants were intensely contaminated, the chlorhexidine-gel-coated meses showed a bacteria-free surface, and only one specimen showed infection signs. The macrophage reaction in this last group was reduced compared to the control (p < 0.05) and gel groups. Conclusions: When incorporated in the carboxymethylcellulose gel, chlorhexidine showed reduced toxicity yet maintained its bactericidal effect at the surgery site. Our findings suggest that this antibacterial gel-coated polypropylene meshes for hernia repair prevent bacterial adhesion to the mesh surface and have no detrimental effects on wound repair.Ministerio de Ciencia, Innovación y Universidade
Mesh fixation using a cyanoacrylate applied as a spray improves abdominal wall tissue repair
19 p.Background: Tissue adhesives are a feasible option to fix a hernia repair mesh, avoiding tissue trauma of suture fixation. Classically, they are applied in the form of a drop, although novel applications such as spray are emerging. This study compares the use of a new experimental cyanoacrylate (n-butyl) in the form of a spray or drops. Materials and methods: Three study groups of New Zealand White rabbits were established (n ? 6 each) according to the method used to fix a 5 3 cm polypropylene mesh in a partial abdominal wall defect model: control group (polypropylene stitches), adhesive drops group, and adhesive spray group. Morphological, immunohistochemical, and biomechanical strength studies were performed at 14 d postimplant. Collagen 1/3 gene ratio was determined by quantitative reverse transcription polymerase chain reaction. Results: In the drops group, the adhesive obstructed the mesh pores and prevented tissue infiltration at the points of application. When the adhesive was applied as a spray, although more numerous, adhesive deposits were smaller and allowed for better host tissue infiltration into the mesh. The inflammatory response was similar in the adhesive groups and more intense than in the control group. Collagen 1/3 mRNA ratio was significantly higher in the spray than the control group. The mechanical resistance of the meshes was similar in all three groups. * Corresponding author. Department of Surgery, Medical and Social Sciences. Faculty of Medicine and Health Sciences, University of Alcala, Ctra. Madrid-Barcelona, Km 33,600, Alcala de Henares, 28871 Madrid, Spain. Tel.: þ34 91 8854540; fax: þ34 91 8854885. E-mail address: [email protected] (J.M. Bellon). 1 These authors contributed equally to this work. 0022-4804/$ e see front matter ª 2019 Elsevier Inc. All rights reserved. https://doi.org/10.1016/j.jss.2019.08.020 Conclusions: The application of the cyanoacrylate adhesive in the form of spray to fix polypropylene meshes in an animal model had a similar inflammatory response compared with droplet application. Neither application impacted the mechanical strength of the repaired area. An increased in collagen 1/3 ratio was found with cyanoacrylate spray compared with suture, and future studies should focus on this pathway.Ministerio de Economía y Competitivida
Behaviour at the peritoneal interface of next generation prosthetic materials for hernia repair
22 p.Background When using a prosthetic material in hernia repair, the behaviour of the mesh at the peritoneal interface is especially important for implant success. Biomaterials developed for their intraperitoneal placement are known as composites and are made up of two different-structure materials, one is responsible for good integration within host tissue and the other is responsible to make contact with the viscera. This study examines the behaviour at the peritoneal level of two composites, the fully degradable Phasix-ST® and the partially degradable Symbotex®. A polypropylene mesh (Optilene®) served as control. Methods Sequential laparoscopy from 3 to 90 days, in a preclinical model in the New Zealand white rabbit, allowed monitoring adhesion formation. Morphological studies were performed to analyse the neoperitoneum formed in the repair process. Total macrophages were identified by immunohistochemical labelling. To identify the different macrophage phenotypes, complementary DNAs were amplified by qRT-PCR using specific primers for M1 (TNF-?/CXCL9) and M2 (MRC1/IL-10) macrophages. Results The percentage of firm and integrated adhesions remained very high in the control group over time. Both composites showed a significant decrease in adhesions at all study times and in qualitative terms were mainly loose. Significant differences were also observed from 7 days onwards between the two composites, increasing the values in Phasix over time. Neoperitoneum thickness for Phasix was significantly greater than those of the other meshes, showing mature and organized neoformed connective tissue. Immunohistochemically, a significantly higher percentage of macrophages was observed in Symbotex. mRNA expression levels for the M2 repair-type macrophages were highest for Phasix but significant differences only emerged for IL-10. Conclusions Fewer adhesions formed to the Symbotex than Phasix implants. Ninety days after implant, total macrophage counts were significantly higher for Symbotex, yet Phasix showed the greater expression of M2 markers related to the tissue repair process.Ministerio de Economía y Competitivida
Repair of abdominal wall defects with biodegradable laminar prostheses polymeric or biological?
11 p.Introduction: Biological and synthetic laminar absorbable prostheses are available for the repair of hernia defects in the abdominal wall. They share the important feature of being gradually degraded in the host, resulting in place the formation of a neotissue. This study was designed to assess the host tissue?s incorporation of collagen bioprostheses and a synthetic absorbable prosthesis. Methods: Partial defects were created in the abdominal walls of 72 New Zealand rabbits and repaired using collagen bioprostheses TutomeshH and StratticeH or a synthetic prosthesis Bio-AH. Specimens were collected for light microscopy, collagens gene and protein expression, macrophage response and biomechanical resistance at 14, 30, 90 and 180 days postimplantation. Results: TutomeshH and Bio-AH were gradually infiltrated by the host tissue and almost completely degraded by 180 days post-implantation. In contrast, StratticeH exhibited material encapsulation, no prosthetic degradation and low cell infiltration at earlier timepoints, whereas at later study time, collagen deposition could be observed within the mesh. In the short term, Bio-AH exhibited higher level of collagen 1 and 3 mRNA expression compared with the two other biological prostheses, which exhibited two peaks of higher expression at 14 and 90 days. The expression of collagen III was homogeneous throughout the study and collagen I deposition was more evident in StratticeH. Macrophage response decreased over time in biomeshes. However, in the synthetic mesh remained high and homogeneous until 90 days. The biomechanical analysis demonstrated the progressively increasing tensile strength of all biomaterials. Conclusions: The tissue infiltration of laminar absorbable prostheses is affected by the structure and composition of the mesh. The synthetic prosthesis exhibited a distinct pattern of tissue incorporation and a greater macrophage response than did the biological prostheses. Of all of the laminar, absorbable biomaterials that were tested in this study, StratticeH demonstrated the optimal levels of integration and degradation.Fundación Médica Mutua MadrileñaMinisterio de Ciencia y Tecnologí
Preclinical bioassay of a novel antibacterial mesh for the repair of abdominal hernia defects
25 p.Background: In hernia surgery, soaking of meshes in antibiotics before implantation is a prophylactic strategy for minimizing the risk of infection while providing minimal, local, drug doses. This study describes the development and application of an antibacterial mesh coating comprising a carboxymethylcellulose gel loaded with rifampicin in a preclinical model of Staphylococcus aureus and S. epidermidis infection in rabbits. Methods: Antibacterial activity and cytocompatibility (with fibroblasts) of unloaded carboxymethylcellulose gel and 0.13 mg/mL rifampicin-carboxymethylcellulose gel were assessed in vitro. Then, partial abdominal wall defects (5 x 2 cm) were created in New Zealand white rabbits (n = 34), the wound inoculated with 0.25 mL of 106 CFU Staphylococcus aureus/ S. epidermidis (n = 17 each), and the defect then repaired with a lightweight, monofilament, large pore polypropylene mesh either uncoated (n = 3) or coated with carboxymethylcellulose gel (n = 7) or rifampicin-carboxymethylcellulose gel (n = 7). By postoperative day 14, coating performance was evaluated by determining bacterial adhesion (via sonication), host tissue incorporation (via histology), macrophage response via immunostaining), and bloodstream drug diffusion (via high-performance liquid chromatography). Results: In vitro, rifampicin-carboxymethylcellulose gel demonstrated great activity against Staphylococcus aureus/S. epidermidis, while being innocuous for fibroblasts. In vivo, rifampicincarboxymethylcellulose gel-coated implants displayed full bacterial clearance and optimal tissue integration, irrespective of the strain of Staphylococcus. In contrast, uncoated and carboxymethylcellulose gel-coated implants exhibited macro/microscopic signs of infection and impaired tissue integration. Macrophage responses were less in rifampicin-carboxymethylcellulose gel implants than in uncoated mesh (Staphylococcus aureus/S. epidermidis; P < .01) and carboxymethylcellulose gel (S. epidermidis; P < .05) implants. Bloodstream levels of rifampicin were undetectable. Conclusion: Soaking meshes in rifampicin-carboxymethylcellulose gel inhibited effectively the bacterial adhesion to the mesh without compromising the tissue repair. This antibiotic gel constitutes an easy-touse and effective prophylactic strategy that potentially reduce the prevalence of postoperative mesh infectionMinisterio de Ciencia, Innovación y Universidade
Thermo-responsive antimicrobial hydrogel for the in-situ coating of mesh materials for hernia repair
The prophylactic coating of prosthetic mesh materials for hernia repair with antimicrobial compounds is commonly performed before implantation of the mesh in the abdominal wall. We propose a novel alternative, which is a rifampicin-loaded thermo-responsive hydrogel formulation, to be applied on the mesh after its implantation. This formulation becomes a gel in-situ once reached body temperature, allowing an optimal coating of the mesh along with the surrounding tissues. In vitro, the hydrogel cytotoxicity was assessed using rabbit fibroblasts and antimicrobial e_cacy was determined against Staphylococcus aureus. An in vivo rabbit model of hernia repair was performed; implanted polypropylene meshes (5 x 2 cm) were challenged with S. aureus (106 CFU), for two study groups?unloaded (n = 4) and 0.1 mg/cm2 rifampicin-loaded hydrogel (n = 8). In vitro, antibacterial activity of the hydrogel lasted for 5 days, without sign of cytotoxicity. Fourteen days after implantation, meshes coated with drug-free hydrogel developed a strong infection and resulted in poor tissue integration. Coating meshes with the rifampicin-loaded hydrogel fully prevented implant infection and permitted an optimal tissue integration. Due to its great performance, this, degradable, thermo-responsive antimicrobial hydrogel could potentially be a strong prophylactic armamentarium to be combined with prosthesis in the surgical field.info:eu-repo/grantAgreement/European Hernia Society/2019
info:eu-repo/grantAgreement/MICINN //SAF2017-89481-Pinfo:eu-repo/grantAgreement/MICINN //SAF2017-89481-
Antibacterial polypropylene mesh fixation with a cyanoacrylate adhesive improves its response to infection
22 p.Background: Antibacterial meshes for hernia repair seek to avoid infection in the patient. As thesebiomaterials are especially prone to bacteria settling at their sutured borders, this study examines whether the use of a cyanoacrylate tissue adhesive could improve mesh behavior at the fixation zones. Methods: First, antibacterial polypropylene meshes were prepared by soaking in 0.05% chlorhexidine, and the response of n-hexyl cyanoacrylate to contamination with Staphylococcus aureus ATCC25923 was assessed in vitro. Then, in a preclinical model, partial defects (5 x 3 cm) were created in the abdominal wall of 18 New Zealand White rabbits and repaired with mesh to establish the following 3 study groups: (1) mesh without chlorhexidine fixed with cyanoacrylate, (2) antibacterial mesh fixed with sutures, and (3) antibacterial mesh fixed with cyanoacrylate (n = 6 each). The implants were inoculated with 106 CFU/ mL of S aureus. At 14 days after surgery, bacterial adhesion to the implant and its integration within host tissue were determined through microbiological, histological and immunohistochemical procedures. Results: As observed in vitro, the cyanoacrylate gave rise to a 1.5-cm bacteria-free margin around the prosthetic mesh. In vivo, the tissue adhesive prevented bacterial adhesion to the fixation zones, reducing infection of chlorhexidine-free meshes and optimizing the efficacy of the antibacterial meshes compared with those fixed with sutures. Conclusion: These findings indicated that cyanoacrylate fixation does not affect mesh integration into the host tissue. Likewise, the antibacterial behavior and tissue response of a chlorhexidine-treated polypropylene mesh is improved when cyanoacrylate is used for its fixation.Ministerio de Ciencia, Innovación y Universidade
- …