18 research outputs found

    Hook plate fixation of Neer type II distal clavicle fractures results in satisfactory patient-reported outcomes but complications and revisions are high

    No full text
    Abstract Background Surgical treatment of distal clavicle fractures Neer type II is challenging. A gold standard has not yet been established, thus various surgical procedures have been described. The purpose of this study is to report the radiological and clinical outcomes using hook plate fixation in Neer type II distal clavicle fractures. Methods We retrospectively reviewed data of 53 patients who underwent hook plate fixation between December 2009 and December 2019 with ≥ 2 years of follow-up. Patients with preexisting pathologies or concomitant injuries of the ipsilateral shoulder were excluded. Pre- and postoperative coracoclavicular distance (CCD), bony union and patient-reported outcomes were collected, including the Constant Score (CS) and Subjective Shoulder Value (SSV). Complications and revisions were recorded. Results At a mean final follow-up of 6.2 years, mean SSV was 91.0% (range, 20–100) and mean CS was 80.9 points (range, 25–99). The mean preoperative CCD was 19.0 mm (range, 5.7–31.8), the mean postoperative CCD was 8.2 mm (range, 4.4–12.2) and the mean CCD following hardware removal was 9.7 mm (range, 4.7–18.8). The loss of reduction following hardware removal was statistically significant (P = 0.007). Eleven (20.8%) patients had complications, with 5 cases of deep or superficial infection (9.4%), four non-unions (7.5%), one periosteosynthetic fracture, one postoperative seroma, one implant failure and one symptomatic acromioclavicular joint arthritis (all 1.9%). A total of 10 patients (18.9%) underwent revision surgery at a mean of 113 (range, 7–631) days. Conclusion Medium-term patient-reported outcomes for hook plate fixation of Neer type II distal clavicle fractures are satisfactory; however, one in five patients suffers a complication with the majority of them requiring revision surgery

    Radiation exposure for pedicle screw placement with three different navigation system and imaging combinations in a sawbone model

    No full text
    Abstract Background Studies have shown that pedicle screw placement using navigation can potentially reduce radiation exposure of surgical personnel compared to conventional methods. Spinal navigation is based on an interaction of a navigation software and 3D imaging. The 3D image data can be acquired using different imaging modalities such as iCT and CBCT. These imaging modalities vary regarding acquisition technique and field of view. The current literature varies greatly in study design, in form of dose registration, as well as navigation systems and imaging modalities analyzed. Therefore, the aim of this study was a standardized comparison of three navigation and imaging system combinations in an experimental setting in an artificial spine model. Methods In this experimental study dorsal instrumentation of the thoracolumbar spine was performed using three imaging/navigation system combinations. The system combinations applied were the iCT/Curve, cCBCT/Pulse and oCBCT/StealthStation. Referencing scans were obtained with each imaging modality and served as basis for the respective navigation system. In each group 10 artificial spine models received bilateral dorsal instrumentation from T11-S1. 2 referencing and control scans were acquired with the CBCTs, since their field of view could only depict up to five vertebrae in one scan. The field of view of the iCT enabled the depiction of T11-S1 in one scan. After instrumentation the region of interest was scanned again for evaluation of the screw position, therefore only one referencing and one control scan were obtained. Two dose meters were installed in a spine bed ventral of L1 and S1. The dose measurements in each location and in total were analyzed for each system combination. Time demand regarding screw placement was also assessed for all system combinations. Results The mean radiation dose in the iCT group measured 1,6 ± 1,1 mGy. In the cCBCT group the mean was 3,6 ± 0,3 mGy and in the oCBCT group 10,3 ± 5,7 mGy were measured. The analysis of variance (ANOVA) showed a significant (p < 0.0001) difference between the three groups. The multiple comparisions by the Kruskall-Wallis test showed no significant difference for the comparison of iCT and cCBCT (p 1 = 0,13). Significant differences were found for the direct comparison of iCT and oCBCT (p 2 < 0,0001), as well as cCBCT and oCBCT (p 3 = 0,02). Statistical analysis showed that significantly (iCT vs. oCBCT p = 0,0434; cCBCT vs. oCBCT p = 0,0083) less time was needed for oCBCT based navigated pedicle screw placement compared to the other system combinations (iCT vs. cCBCT p = 0,871). Conclusion Under standardized conditions oCBCT navigation demanded twice as much radiation as the cCBCT for the same number of scans, while the radiation exposure measured for the iCT and cCBCT for one scan was comparable. Yet, time effort was significantly less for oCBCT based navigation. However, for transferability into clinical practice additional studies should follow evaluating parameters regarding feasibility and clinical outcome under standardized conditions

    Validation of radiological reduction criteria with intraoperative cone beam CT in unstable syndesmotic injuries

    No full text
    Purpose!#!Acute unstable syndesmotic lesions are regularly treated with closed or open reduction and fixation with either a positioning screw or tight rope. Conventional fluoroscopy is limited to identify a malreduction of the ankle mortise. The aim of the study was to validate the reduction criteria of intraoperative cone beam CT in unstable syndesmotic injuries by analyzing the clinical outcome.!##!Methods!#!Acute unstable syndesmotic injuries were treated with a positioning screw fixation, and the reduction in the ankle mortise was evaluated with intraoperative cone beam CT. The patients were grouped postoperatively according to the radiological reduction criteria in the intraoperative 3D images. The reduction criteria were unknown to the surgeons. Malreduction was assumed if one or more reduction criteria were not fulfilled.!##!Results!#!Seventy-three of the 127 patients could be included in the study (follow-up rate 57.5%). For 41 patients (56.2%), a radiological optimal reduction was achieved (Group 1), and in 32 patients (43.8%) a radiological adverse reduction was found (Group 2). Group 1 scored significantly higher in the Olerud/Molander score (92.44 ± 10.73 vs. 65.47 ± 28.77) (p = 0.003), revealed a significantly higher range of motion (ROM) (53.44 vs. 24.17°) (p = 0.001) and a significantly reduced Kellgren/Lawrence osteoarthritis score (1.24 vs. 1.79) (p = 0.029). The linear regression analysis revealed a correlation for the two groups with the values scored in the Olerud/Molander score (p &amp;lt; 0.01).!##!Conclusion!#!The reduction criteria in intraoperative cone beam CT applied to unstable syndesmotic injuries could be validated. Patients with an anatomic reduced acute unstable syndesmotic injury according to the criteria have a significantly better clinical outcome

    Long-term results after non-operative and operative treatment of radial neck fractures in adults

    No full text
    Abstract Background The aim of this study is to determine the functional long-term outcome after non-operative and operative treatment of radial neck fractures in adults. Methods Thirty-four consecutive patients with a mean age of 46.4 (18.0 to 63.0) years with a fracture of the radial neck who were treated between 2000 and 2014 were examined regarding the clinical and radiological outcome. Twenty patients were treated non-operatively, and 14 patients underwent surgery. Results After a mean follow-up of 5.7 (2.0 to 15.7) years, the clinical scores showed good results in both groups. The Disabilities of Arm, Shoulder and Hand score was 16.1 (0 to 71.6) in the non-operative group and 8.8 (0 to 50.8) in the operative group, respectively. The Mayo Elbow Performance Score was 80.0 (30 to 95) in the non-operative group and 82.5 (35 to 95) in the non-operative group, respectively. The initial angle of the radial head towards the shaft (RHSA) was significantly higher in the operative group in the anterior-posterior plane (12.8° [2 to 23] vs. 26.3° [1 to 90], p = 0.015). In the follow-up radiographs, the RHSA was significantly lower in the operative group (15.1° [3 to 30] vs. 10.9° [3 to 18], p = 0.043). Five patients developed 7 complications in the non-operative group, and 7 patients developed 12 complications in the operative group. Revision rates were higher in the operative groups as 1 patient received radial head resection in the non-operative (5%) group while 7 patients in the operative group (50%) needed revision surgery. Conclusion A good functional long-term outcome can be expected after operative and non-operative treatment of radial neck fractures in adults. If needed due to major displacement, open reduction is associated with a higher risk of complications and the need for revision surgery but can achieve similar clinical results. Trial registration DRKS DRKS00012836 (retrospectively registered

    Comparing Temporary Immobilization Using Cast and External Fixator in Unimalleolar Ankle Fracture Dislocations: A Retrospective Case Series

    No full text
    Studies have reported a high percentage of ankle fracture dislocations with secondary loss of reduction during primary treatment with a splint or cast. This study aimed to assess the rate of secondary loss of reduction in unimalleolar ankle fracture dislocations treated primarily with a cast or external fixator, identify the potential influence of fracture morphology, and investigate the potential implications. Unimalleolar ankle fracture dislocations with and without posterior malleolar fracture between 2011 and 2020 were included. Patients were categorized into two groups, depending on the method of temporary treatment. Fracture morphology, time to definitive surgery, and soft-tissue complications were compared. Of 102 patients, loss of reduction tended to occur more often in the cast group (17.3%) than in the external fixator group (6.0%). The presence of a posterior malleolar fracture did not have a significant influence on loss of reduction in cast immobilization; however, the fragment proved to be significantly bigger in cases with loss of reduction. No statistically significant differences in soft tissue complications or time to definitive surgery were found. Surgeons should consider the application of interval external fixation in the primary treatment of unimalleolar ankle fracture dislocations with additional posterior malleolar fractures

    Influence of ankle joint position on angles and distances of the ankle mortise using intraoperative cone beam CT: A cadaveric study.

    No full text
    BackgroundThe precise anatomical reduction of the ankle mortise is crucial for the clinical outcome in unstable syndesmotic injuries. Intraoperative cone beam computed tomography (CT), in addition to two-dimensional fluoroscopy, provides detailed information about the reduction and implant placement. The aim of this study was to analyze the influence of the joint position on the fibula position in the incisural notch and to determine the inter- and intraindividual anatomical differences in the intact ankle joints.MethodsA total of 20 fresh-frozen lower legs disarticulated in the knee joint of 10 individuals were included. The measurements were performed using a cone beam CT. The distances and angles were measured in the standard imaging planes. The mean values of distances and angles were compared during the different joint positions: 10° dorsiflexion, 0° neutral position and 20° plantar flexion.ResultsThe influence of the joint position was on average as follows: The anterior tibiofibular distance was 3.68 mm in 10° dorsiflexion, 3.66 mm (0° neutral position) and 3.59 mm (20° plantar flexion). The posterior tibiofibular distance measured 7.82mm, 7.76mm and 7.82mm. The rotation of the fibula measured ten millimeters proximal the joint line was 1.2°, 1.3° and 1.05°. The fibular rotation determined 4mm was 9.3°, 9.4° and 9.4°. On average, the following intraindividual variations were observed: superior tibiotalar clear space of 0.27mm and 0.15mm medial; and anterior tibiofibular distance of 0.42mm, 0.38mm posterior and 0.24mm in the incisural notch. The proximal angle of the fibular rotation was 0.2° and distal 0.4°. The interindividual variations of the angles and distances exceeded the intraindividual values partly by 3 to 4 fold.ConclusionsWithin the scope of this study neither the tibiofibular distance, nor the tibiofibular angle changed significantly through the different joint positions. The intraindividual differences were little while the interindividual variations of the parameters were distinctive

    Improving Medical Photography in a Level 1 Trauma Center by Implementing a Specialized Smartphone-Based App in Comparison to the Usage of Digital Cameras: Prospective Panel Study

    No full text
    BackgroundMedical photography plays a pivotal role in modern health care, serving multiple purposes ranging from patient care to medical documentation and education. Specifically, it aids in wound management, surgical planning, and medical training. While digital cameras have traditionally been used, smartphones equipped with specialized apps present an intriguing alternative. Smartphones offer several advantages, including increased usability and efficiency and the capability to uphold medicolegal standards more effectively and consistently. ObjectiveThis study aims to assess whether implementing a specialized smartphone app could lead to more frequent and efficient use of medical photography. MethodsWe carried out this study as a comprehensive single-center panel investigation at a level 1 trauma center, encompassing various settings including the emergency department, operating theaters, and surgical wards, over a 6-month period from June to November 2020. Using weekly questionnaires, health care providers were asked about their experiences and preferences with using both digital cameras and smartphones equipped with a specialized medical photography app. Parameters such as the frequency of use, time taken for image upload, and general usability were assessed. ResultsA total of 65 questionnaires were assessed for digital camera use and 68 for smartphone use. Usage increased significantly by 5.4 (SD 1.9) times per week (95% CI 1.7-9.2; P=.005) when the smartphone was used. The time it took to upload pictures to the clinical picture and archiving system was significantly shorter for the app (mean 1.8, SD 1.2 min) than for the camera (mean 14.9, SD 24.0 h; P<.001). Smartphone usage also outperformed the digital camera in terms of technical failure (4.4% vs 9.7%; P=.04) and for the technical process of archiving (P<.001) pictures to the picture archiving and communication system (PACS) and display images (P<.001) from it. No difference was found in regard to the photographer’s intent (P=.31) or reasoning (P=.94) behind the pictures. Additionally, the study highlighted that potential concerns regarding data security and patient confidentiality were also better addressed through the smartphone app, given its encryption capabilities and password protection. ConclusionsSpecialized smartphone apps provide a secure, rapid, and user-friendly platform for medical photography, showing significant advantages over traditional digital cameras. This study supports the notion that these apps not only have the potential to improve patient care, particularly in the realm of wound management, but also offer substantial medicolegal and economic benefits. Future research should focus on additional aspects such as patient comfort and preference, image resolution, and the quality of photographs, as well as seek to corroborate these findings through a larger sample size

    Wire Placement in the Sustentaculum Tali Using a 2D Projection-Based Software Application for Mobile C-Arms: Cadaveric Study

    No full text
    Background: Indirect screw fixation of the sustentaculum tali in the lateral-medial direction can be challenging due to the complex calcaneal anatomy. A novel 2-dimensional (2D) projection-based software application detects Kirschner wires (K-wires) and visualizes their intended direction as a colored trajectory. The aim of this prospectively randomized cadaver study was to investigate whether the software would facilitate the indirect K-wire placement in the sustentaculum tali. Methods: In 20 cadaver foot specimens, K-wires were placed indirectly in the sustentaculum tali by an experienced and an inexperienced surgeon, with and without using the application. Number of placement attempts, duration of procedure, fluoroscopy time, and number of individual fluoroscopy images were recorded. Each wire's position was analyzed in a 3-dimensional (3D) C-arm scan by an experienced blinded investigator. Results: Use of the software by the inexperienced surgeon significantly reduced the number of placement attempts from 3.2 to 1.2 (P = .006). The application also reduced operating time, from 273 s to 199 s (P = .15), and fluoroscopy time, from 41 s to 29 s (P = .15). Using the software, the experienced surgeon had a longer operating time (139 s to 183 s; P = .30), longer fluoroscopy time (5.6 s to 9.2 s; P = .17), and more individual fluoroscopy images (11.6 to 14.8; P = .30). Wire position did not show significant differences in both cases. Conclusion: During indirect K-wire placement in the sustentaculum tali, the software appeared to be a useful tool for the inexperienced surgeon. In our chosen study setting, the experienced surgeon did not benefit from the software. Clinical Relevance: Possible indications for the software would be fractures of the proximal femur, sacrum, sacroiliac instabilities, vertebral bodies, scaphoid, Lisfranc joint, talus and calcaneus

    An uncertainty-aware, shareable, and transparent neural network architecture for brain-age modeling

    No full text
    The deviation between chronological age and age predicted from neuroimaging data has been identified as a sensitive risk marker of cross-disorder brain changes, growing into a cornerstone of biological age research. However, machine learning models underlying the field do not consider uncertainty, thereby confounding results with training data density and variability. Also, existing models are commonly based on homogeneous training sets, often not independently validated, and cannot be shared because of data protection issues. Here, we introduce an uncertainty-aware, shareable, and transparent Monte Carlo dropout composite quantile regression (MCCQR) Neural Network trained on N = 10,691 datasets from the German National Cohort. The MCCQR model provides robust, distribution-free uncertainty quantification in high-dimensional neuroimaging data, achieving lower error rates compared with existing models. In two examples, we demonstrate that it prevents spurious associations and increases power to detect deviant brain aging. We make the pretrained model and code publicly available

    Genetic, individual, and familial risk correlates of brain network controllability in major depressive disorder

    No full text
    Many therapeutic interventions in psychiatry can be viewed as attempts to influence the brain’s large-scale, dynamic network state transitions. Building on connectome-based graph analysis and control theory, Network Control Theory is emerging as a powerful tool to quantify network controllability—i.e., the influence of one brain region over others regarding dynamic network state transitions. If and how network controllability is related to mental health remains elusive. Here, from Diffusion Tensor Imaging data, we inferred structural connectivity and inferred calculated network controllability parameters to investigate their association with genetic and familial risk in patients diagnosed with major depressive disorder (MDD, n = 692) and healthy controls (n = 820). First, we establish that controllability measures differ between healthy controls and MDD patients while not varying with current symptom severity or remission status. Second, we show that controllability in MDD patients is associated with polygenic scores for MDD and psychiatric cross-disorder risk. Finally, we provide evidence that controllability varies with familial risk of MDD and bipolar disorder as well as with body mass index. In summary, we show that network controllability is related to genetic, individual, and familial risk in MDD patients. We discuss how these insights into individual variation of network controllability may inform mechanistic models of treatment response prediction and personalized intervention-design in mental health
    corecore