268 research outputs found

    Chemochemical caries removal: a review of the techniques and latest developments

    Get PDF
    Chemomechanical caries removal involves the chemical softening of carious dentine followed by its removal by gentle excavation. The reagent involved is generated by mixing amino acids with sodium hypochlorite; N-monochloroamino acids are formed which selectively degrade demineralised collagen in carious dentine. The procedure requires 5-15 minutes but avoids the painful removal of sound dentine thereby reducing the need for local anaesthesia. It is well suited to the treatment of deciduous teeth, dental phobics and medically compromised patients. The dentine surface formed is highly irregular and well suited to bonding with composite resin or glass ionomer. When complete caries removal is achieved, the dentine remaining is sound and properly mineralised. The system was originally marketed in the USA in the 1980's as Caridex. Large volumes of solution and a special applicator system were required. A new system, Carisolv, has recently been launched on to the market. This comes as a gel, requires volumes of 0.2-1.0 ml and is accompanied by specially designed instruments

    Interactive manipulation of microparticles in an octagonal sonotweezer

    Get PDF
    An ultrasonic device for micro-patterning and precision manipulation of micrometre-scale particles is demonstrated. The device is formed using eight piezoelectric transducers shaped into an octagonal cavity. By exciting combinations of transducers simultaneously, with a controlled phase delay between them, different acoustic landscapes can be created, patterning micro-particles into lines, squares, and more complex shapes. When operated with all eight transducers the device can, with appropriate phase control, manipulate the two dimensional acoustic pressure gradient; it thus has the ability to position and translate a single tweezing zone to different locations on a surface in a precise and programmable manner

    Wide-Range Optical CMOS-Based Diagnostics

    Get PDF
    Colorimetric, chemiluminescence and refractive index based diagnostics are some of the most important sensing techniques in biomedical science and clinical medicine. Conventionally laboratories and medical clinics rely on bulky and dedicated equipment for each diagnostic technique independently. In this paper, we present CMOS sensor based solutions, comprising a single photon avalanche detector array and photodiode array. The CMOS platform offers low cost integration and wide range of light-based diagnostic techniques, leading to development of point-of-care devices

    A colorimetric CMOS-based platform for rapid total serum cholesterol quantification

    Get PDF
    Elevated cholesterol levels are associated with a greater risk of developing cardiovascular disease and other illnesses, making it a prime candidate for detection on a disposable biosensor for rapid point of care diagnostics. One of the methods to quantify cholesterol levels in human blood serum uses an optically mediated enzyme assay and a bench top spectrophotometer. The bulkiness and power hungry nature of the equipment limits its usage to laboratories. Here, we present a new disposable sensing platform that is based on a complementary metal oxide semiconductor process for total cholesterol quantification in pure blood serum. The platform that we implemented comprises readily mass-manufacturable components that exploit colorimetric changes of cholesterol oxidase and cholesterol esterase reactions. We have shown that our quantification results are comparable to that obtained by a bench top spectrophotometer. Using the implemented device, we have measured cholesterol concentration in human blood serum as low as 29 μM with a limit of detection at 13 μM, which is approximately 400 times lower than average physiological range, implying that our device also has the potential to be used for applications that require greater sensitivity

    Noise characteristics with CMOS sensor array scaling

    Get PDF
    An important consideration when scaling semiconductor sensor devices is the effect it may have on noise performance. Overall signal to noise ratio can be improved both by increasing sensor size, or alternatively by averaging the signal from two or more smaller sensors. In the design of sensor systems it is not immediately clear which is the best strategy to pursue. In this paper, we present a detailed theoretical and experimental study based on three different sensor arrays that show that an array of small independent sensors is always less noisy than a large sensor of the same size

    The Multicorder: A Handheld Multimodal Metabolomics-on-CMOS Sensing Platform

    Get PDF
    The use of CMOS platforms in medical point-of-care applications, by integrating all steps from sample to data output, has the potential to reduce the diagnostic cost and the time from days to seconds. Here we present the `Multicorder' technology, a handheld versatile multimodal platform for rapid metabolites quantification. The current platform is composed of a cartridge, a reader and a graphic user interface. The sensing core of the cartridge is the CMOS chip which integrates a 16×16 array of multi-sensor elements. Each element is composed of two optical and one chemical sensor. The platform is therefore capable of performing multi-mode measurements: namely colorimetric, chemiluminescence, pH sensing and surface plasmon resonance. In addition to the reader that is employed for addressing, data digitization and transmission, a tablet computer performs data collection, visualization, analysis and storage. In this paper, we demonstrate colorimetric, chemiluminescence and pH sensing on the same platform by on-chip quantification of different metabolites in their physiological range. The platform we have developed has the potential to lead the way to a new generation of commercial devices in the footsteps of the current commercial glucometers for quick multi-metabolite quantification for both acute and chronic medicines

    Multimodal integrated sensor platform for rapid biomarker detection

    Get PDF
    Precision metabolomics and quantification for cost-effective, rapid diagnosis of disease are key goals in personalized medicine and point-of-care testing. Presently, patients are subjected to multiple test procedures requiring large laboratory equipment. Microelectronics has already made modern computing and communications possible by integration of complex functions within a single chip. As More than Moore technology increases in importance, integrated circuits for densely patterned sensor chips have grown in significance. Here, we present a versatile single CMOS chip forming a platform to address personalized needs through on-chip multimodal optical and electrochemical detection that will reduce the number of tests that patients must take. The chip integrates interleaved sensing subsystems for quadruple-mode colorimetric, chemiluminescent, surface plasmon resonance and hydrogen ion measurements. These subsystems include a photodiode array and a single photon avalanche diode array, with some elements functionalized to introduce a surface plasmon resonance mode. The chip also includes an array of ion sensitive field effect transistors. The sensor arrays are distributed uniformly over an active area on the chip surface in a scalable and modular design. Bio-functionalization of the physical sensors yields a highly selective simultaneous multiple-assay platform in a disposable format. We demonstrate its versatile capabilities through quantified bioassays performed on-chip for glucose, cholesterol, urea and urate, each within their naturally occurring physiological range
    corecore