15 research outputs found

    Endovascular Aortic Repair

    Get PDF
    __Abstract__ Endovascular aortic repair is a widespread alternative for a multitude of aortic pathologies, yet tools and understanding are still rapidly advancing. The aim of this thesis is to contribute to current knowledge on risk factors for endovascular aortic repair – exploring the binomial patient-device – to clarify endovascular-specific complications and contribute to a risk-based strategy of postoperative surveillance. In Part One, the authors address controversial issues related to endovascular repa

    Early sac shrinkage predicts a low risk of late complications after endovascular aortic aneurysm repair

    Get PDF
    Background Aneurysm shrinkage has been proposed as a marker of successful endovascular aneurysm repair (EVAR). Patients with early postoperative shrinkage may experience fewer subsequent complications, and consequently require less intensive surveillance. Methods Patients undergoing EVAR from 2000 to 2011 at three vascular centres (in 2 countries), who had two imaging examinations (postoperative and after 6-18 months), were included. Maximum diameter, complications and secondary interventions during follow-up were registered. Patients were categorized according to early sac dynamics. The primary endpoint was freedom from late complications. Secondary endpoints were freedom from secondary intervention, postimplant rupture and direct (type I/III) endoleaks. Results Some 597 EVARs (71·1 per cent of all EVARs) were included. No shrinkage was observed in 284 patients (47·6 per cent), moderate shrinkage (5-9 mm) in 142 (23·8 per cent) and major shrinkage (at least 10 mm) in 171 patients (28·6 per cent). Four years after the index imaging, the rate of freedom from complications was 84·3 (95 per cent confidence interval 78·7 to 89·8), 88·1 (80·6 to 95·5) and 94·4 (90·1 to 98·7) per cent respectively. No shrinkage was an independent risk factor for late complications compared with major shrinkage (hazard ratio (HR) 3·11; P < 0·001). Moderate compared with major shrinkage (HR 2·10; P = 0·022), early postoperative complications (HR 3·34; P < 0·001) and increasing abdominal aortic aneurysm baseline diameter (HR 1·02; P = 0·001) were also risk factors for late complications. Freedom from secondary interventions and direct endoleaks was greater for patients with major sac shrinkage. Conclusion Early change in aneurysm sac diameter is a strong predictor of late complications after EVAR. Patients with major sac shrinkage have a very low risk of complications for up to 5 years. This parameter may be used to tailor postoperative surveillance. Towards personalized surveillanc

    Comparison of midterm results of endovascular aneurysm repair for ruptured and elective abdominal aortic aneurysms

    Get PDF
    Objective: Endovascular aneurysm repair (EVAR) became an increasingly preferred modality for abdominal aortic aneurysm (AAA) repair both in elective AAA repair (el-EVAR) and EVAR of a ruptured AAA (r-EVAR) setting. Ruptured AAAs usually have more hostile anatomies and less time for planning. Consequently, more complications may arise after r-EVAR. The purpose of this study was to compare mi-term outcomes between r-EVAR and el-EVAR. Methods: A retrospective cohort analysis of patients undergoing EVAR from 2000 to 2015 at a tertiary institution was performed. Patients with previous aortic surgery, nonatherosclerotic AAA and isolated iliac aneurysms were excluded. In-hospital casualties or patients who were intraoperatively converted to open repair were also excluded. For the midterm outcome analysis, only patients with at least two postoperative examinations (a 30-day computed tomography scan and a second postoperative examination performed 6 months or later) were considered. The primary end point was freedom from aneurysm-related complications (a composite of type I or III endoleak, aneurysm sac growth, migration of more than 5 mm, device integrity failure, AAA-related death, late postimplant rupture, or AAA-related secondary intervention). Freedom from secondary interventions, neck-related events (defined as a composite of type IA endoleak, migration of more than 5 mm, or preemptive neck-related secondary intervention) and late survival were secondary end points. The impact of device instructions for use (IFU) compliance on neck events was also assessed. Results: The study included 565 patients (65 r-EVAR and 500 el-EVAR). Eighty-two patients were treated outside proximal neck IFU, 13 in the r-EVAR group (21.3%) and 69 (14.5%) in the el-EVAR (P =.16). During the index hospitalization, there were more complications (12.3% vs 3.2%; P =.001) and reinterventions (12.3% vs 2.8%; P <.001) in the r-EVAR group. After discharge, median clinical follow-up time was 4.3 years (interquartile range, 2.1-7.0 years) without differences between both groups. Five-year freedom from AAA-related complications was 53.9% in the r-EVAR group and 65.4% in the el-EVAR (P =.21). In multivariable analysis the r-EVAR group was not at increased risk for late complications (hazard ratio [HR], 0.94; 95% confidence interval [CI], 0.54-1.61; P =.81). Five-year freedom from neck-related events was 74% in r-EVAR and 82% in the el-EVAR group (P =.345). Patients treated outside neck IFU were at greater risk for neck-related events both in r-EVAR (HR, 6.5; 95% CI, 1.8-22.9; P =.004) and el-EVAR group (HR, 2.6; 95% CI, 1.5-4.5; P <.001). Freedom from secondary interventions at 5 years was 63.0% for r-EVAR and 76.9% for el-EVAR (P =.16). Survival at 5 years was 68.8% in the r-EVAR group and 73.3% in the el-EVAR group (P =.30). Conclusions: Durable and sustainable midterm outcomes were found for both r-EVAR and el-EVAR patients who survived the postoperative period. Patients treated out

    Treatment of post-implantation aneurysm growth by laparoscopic sac fenestration: Long-term results

    Get PDF
    Objectives: Sac growth after endovascular aneurysm repair (EVAR) is an important finding, which may influence prognosis. In case of a type II endoleak or endotension, clipping of side branches and subsequent sac fenestration has been presented as a therapeutic alternative. The long-term clinical efficacy of this procedure is unknown. Methods: The study included eight patients who underwent laparoscopic aortic collateral clipping and sac fenestration for enlarging aneurysms following EVAR. Secondary interventions and clinical outcome were retrieved from hospital records. Sac behaviour was evaluated measuring volumes on periodical computed tomography angiography (CTA) imaging using dedicated software. Results: Follow-up had a median length of 6.6 (range 0.6-8.6) years. During this time, only three pati

    Familial abdominal aortic aneurysm is associated with more complications after endovascular aneurysm repair

    Get PDF
    Objective A familial predisposition to abdominal aortic aneurysms (AAAs) is present in approximately one-fifth of patients. Nevertheless, the clinical implications of a positive family history are not known. We investigated the risk of aneurysm-related compli

    Clinical outcome and morphologic determinants of mural thrombus in abdominal aortic endografts

    Get PDF
    Objective Endograft mural thrombus has been associated with stent graft or limb thrombosis after endovascular aneurysm repair (EVAR). This study aimed to identify clinical and morphologic determinants of endograft mural thrombus accumulation and its influence on thromboembolic events after EVAR. Methods A prospectively maintained database of patients treated by EVAR at a tertiary institution from 2000 to 2012 was analyzed. Patients treated for degenerative infrarenal abdominal aortic aneurysms and with available imaging for thrombus analysis were considered. All measurements were performed on three-dimensional center-lumen line computed tomography angiography (CTA) reconstructions. Patients with thrombus accumulation within the endograft's main body with a thickness >2 mm and an extension >25% of the main body's circumference were included in the study group and compared with a control group that included all remaining patients. Clinical and morphologic variables were assessed for association with significant thrombus accumulation within the endograft's main body by multivariate regression analysis. Estimates for freedom from thromboembolic events were obtained by Kaplan-Meier plots. Results Sixty-eight patients (16.4%) presented with endograft mural thrombus. Median follow-up time was 3.54 years (interquartile range, 1.99-5.47 years). In-graft mural thrombus was identified on 30-day CTA in 22 patients (32.4% of the study group), on 6-month CTA in 8 patients (11.8%), and on 1-year CTA in 17 patients (25%). Intraprosthetic thrombus progressively accumulated during the study period in 40 patients of the study group (55.8%). Overall, 17 patients (4.1%) presented with endograft or limb occlusions, 3 (4.4%) in the thrombus group and 14 (4.1%) in the control group (P =.89). Thirty-one patients (7.5%) received an aortouni-iliac (AUI) endograft. Two endograft occlusions were identified among AUI devices (6.5%; overall, 0.5%). None of these patients showed thrombotic deposits in the main body, nor were any outflow abnormalities identified on the immediately preceding CTA. Estimated freedom from thromboembolic events at 5 years was 95% in both groups (P =.97). Endograft thrombus accumulation was associated with >25% proximal aneurysm neck thrombus coverage at baseline (odds ratio [OR], 1.9; 95% confidence interval [CI], 1.1-3.3), neck length ≤15 mm (OR, 2.4; 95% CI, 1.3-4.2), proximal neck diameter ≥30 mm (OR, 2.4; 95% CI, 1.3-4.6), AUI (OR, 2.2; 95% CI, 1.8-5.5), or polyester-covered stent grafts (OR, 4.0; 95% CI, 2.2-7.3) and with main component "barrel-like" configuration (OR, 6.9; 95% CI, 1.7-28.3). Conclusions Mural thrombus formation within the main body of the endograft is related to different endograft configurations, main body geometry, and device fabric but appears to have no association with the occurrence of thromboembolic events over time

    The influence of neck thrombus on clinical outcome and aneurysm morphology after endovascular aneurysm repair

    No full text
    Objective: This study investigated the influence of significant aneurysm neck thrombus in clinical and morphologic outcomes after endovascular aneurysm repair (EVAR). Methods: The patient population was derived from a prospective EVAR database from two university institutions in The Netherlands from 2004 to 2008. Patients with significant thrombus in the neck (>2 mm in thickness in at least >25% of circumference) were identified as the thrombus group and were compared with the remaining patients without neck thrombus (no-thrombus group), treated within the same period. The primary end point was clinical success. Secondary end points included technical success and rates of decline in renal function. Detailed morphologic analysis of the aortic neck was serially performed for the thrombus group patients to assess changes in thrombus volume. Results: The study included 389 patients: 43 (39 men; mean age of 72.3 years) met the criteria for the thrombus group; of these, 31 (72%) had significant thrombus in >50% of the aortic neck circumference, and 8 (19%) had circumferential thrombus >2-mm thick. Median follow-up was 3.34 years (interquartile range, 2.67-4.72). The estimated 5-year clinical success rate was 74% for the thrombus group and 62% for the no-thrombus group (P =.23). Endograft migration was more frequent in the thrombus group (P =.02). Multivariable Cox regression analysis showed a significant association between migration and use of a device without active fixation (hazard ratio, 4.9; 95% confidence interval, 1.31-18.23; P =.018) but not with the presence of neck thrombus (P =.063). No differences were found in the rates of decline in estimated glomerular filtration rate at 30 days and during follow-up between the thrombus and no-thrombus groups. The thrombus volume in the first 10 mm of aortic neck was progressively reduced over time until it was not measurable in most patients, resulting in complete circular attachment of the endograft to the vessel wall. Conclusions: Our findings suggest that the presence of aneurysm neck thrombus has no significant influence on short-term and midterm EVAR results
    corecore