16 research outputs found

    Hammering K-wires is Superior to Drilling with Irrigation

    Get PDF
    Cooling during drilling Kirschner wires is not always effective in preventing thermal related damage. In this study, we used a human in vitro model and compared temperature elevation, insertion time, and extraction force between three Kirschner wire insertion methods—drilling with and without irrigation and pneumatic hammering. Forty five Kirschner wires were inserted into 15 fresh human cadaver metacarpals. All three insertion methods were applied in each metacarpal. Drilling without irrigation resulted in a temperature elevation of 67.25 ± 5.4 ºC with significantly lower values for drilling with irrigation (4.15 ± 0.6 ºC) and pneumatic hammering (31.52 ± 3.4 ºC). The insertion time for pneumatic hammering (47.63 ± 8.8 s) was significantly lower compared to drilling without irrigation (263.16 ± 36.5 s) and drilling with irrigation (196.10 ± 28.5 s). Extraction forces after drilling without irrigation, drilling with irrigation, and pneumatic hammering were 39.85 ± 4.1 N, 57.81 ± 6.5 N, and 62.23 ± 6.7 N, respectively. Pneumatic hammering is superior to drilling without irrigation, especially when irrigation is not possible

    Extrahepatic perfusion and incomplete hepatic perfusion after hepatic arterial infusion pump implantation:incidence and clinical implications

    Get PDF
    INTRODUCTION: This study investigates the incidence of extrahepatic perfusion and incomplete hepatic perfusion at intraoperative methylene blue testing and on postoperative nuclear imaging in patients undergoing hepatic arterial infusion pump (HAIP) chemotherapy.METHODS:The first 150 consecutive patients who underwent pump implantation in the Netherlands were included. All patients underwent surgical pump implantation with the catheter in the gastroduodenal artery. All patients underwent intraoperative methylene blue testing and postoperative nuclear imaging ( 99mTc-Macroaggregated albumin SPECT/CT) to determine perfusion via the pump. RESULTS: Patients were included between January-2018 and December-2021 across eight centers. During methylene blue testing, 29.3% had extrahepatic perfusion, all successfully managed intraoperatively. On nuclear imaging, no clinically relevant extrahepatic perfusion was detected (0%, 95%CI: 0.0-2.5%). During methylene blue testing, 2.0% had unresolved incomplete hepatic perfusion. On postoperative nuclear imaging, 8.1% had incomplete hepatic perfusion, leading to embolization in only 1.3%.CONCLUSION: Methylene blue testing during pump placement for intra-arterial chemotherapy identified extrahepatic perfusion in 29.3% of patients, but could be resolved intraoperatively in all patients. Postoperative nuclear imaging found no clinically relevant extrahepatic perfusion and led to embolization in only 1.3% of patients. The role of routine nuclear imaging after HAIP implantation should be studied in a larger cohort.</p

    Extrahepatic perfusion and incomplete hepatic perfusion after hepatic arterial infusion pump implantation:incidence and clinical implications

    Get PDF
    INTRODUCTION: This study investigates the incidence of extrahepatic perfusion and incomplete hepatic perfusion at intraoperative methylene blue testing and on postoperative nuclear imaging in patients undergoing hepatic arterial infusion pump (HAIP) chemotherapy.METHODS:The first 150 consecutive patients who underwent pump implantation in the Netherlands were included. All patients underwent surgical pump implantation with the catheter in the gastroduodenal artery. All patients underwent intraoperative methylene blue testing and postoperative nuclear imaging ( 99mTc-Macroaggregated albumin SPECT/CT) to determine perfusion via the pump. RESULTS: Patients were included between January-2018 and December-2021 across eight centers. During methylene blue testing, 29.3% had extrahepatic perfusion, all successfully managed intraoperatively. On nuclear imaging, no clinically relevant extrahepatic perfusion was detected (0%, 95%CI: 0.0-2.5%). During methylene blue testing, 2.0% had unresolved incomplete hepatic perfusion. On postoperative nuclear imaging, 8.1% had incomplete hepatic perfusion, leading to embolization in only 1.3%.CONCLUSION: Methylene blue testing during pump placement for intra-arterial chemotherapy identified extrahepatic perfusion in 29.3% of patients, but could be resolved intraoperatively in all patients. Postoperative nuclear imaging found no clinically relevant extrahepatic perfusion and led to embolization in only 1.3% of patients. The role of routine nuclear imaging after HAIP implantation should be studied in a larger cohort.</p

    Reproducible radiomics through automated machine learning validated on twelve clinical applications

    Get PDF
    Radiomics uses quantitative medical imaging features to predict clinical outcomes. Currently, in a new clinical application, findingthe optimal radiomics method out of the wide range of available options has to be done manually through a heuristic trial-anderror process. In this study we propose a framework for automatically optimizing the construction of radiomics workflows perapplication. To this end, we formulate radiomics as a modular workflow and include a large collection of common algorithms foreach component. To optimize the workflow per application, we employ automated machine learning using a random search andensembling. We evaluate our method in twelve different clinical applications, resulting in the following area under the curves: 1)liposarcoma (0.83); 2) desmoid-type fibromatosis (0.82); 3) primary liver tumors (0.80); 4) gastrointestinal stromal tumors (0.77);5) colorectal liver metastases (0.61); 6) melanoma metastases (0.45); 7) hepatocellular carcinoma (0.75); 8) mesenteric fibrosis(0.80); 9) prostate cancer (0.72); 10) glioma (0.71); 11) Alzheimer’s disease (0.87); and 12) head and neck cancer (0.84). Weshow that our framework has a competitive performance compared human experts, outperforms a radiomics baseline, and performssimilar or superior to Bayesian optimization and more advanced ensemble approaches. Concluding, our method fully automaticallyoptimizes the construction of radiomics workflows, thereby streamlining the search for radiomics biomarkers in new applications.To facilitate reproducibility and future research, we publicly release six datasets, the software implementation of our framework,and the code to reproduce this study

    A simple blind tenolysis for flexor carpi radialis tendinopathy

    No full text
    BACKGROUND: Flexor carpi radialis (FCR) tendinopathy is an entity with a chronic form (repetitiveness of work) and an acute form (acute overstretching of the wrist). Confirmation of this syndrome can be established by injection of a small amount of a local anesthetic in the sheet of the FCR at this tender point. Complete relieve of the symptoms after injection confirms the existence of a tendinopathy of the FCR. Whereas rest and/or local application of steroids do not have a persistent effect on the short term outcome, a tenolysis could be performed. Before performing a tenolysis underlying causes should be excluded or treated. METHODS: In this article a simple and save technique is described, using a small Beaver knife to open the osteofibrous tunnel of the flexor carpi radialis tendon, without opening the carpal tunnel. RESULTS: Relieve of complaints could be reached up to almost two third of all cases. CONCLUSION: In cases in which non-operative treatment is not effective regarding FCR tendinopathy, a simple blind technique by opening the osteofibrous tunnel could be successful

    One century of Kirschner wires and Kirschner wire insertion techniques: A historical review

    No full text
    A century ago, in 1909, Martin Kirschner (1879-942) introduced a smooth pin, presently known as the Kirschner wire (K-wire). The K-wire was initiallly used for skeletal traction and is now currently used for many different goals. The development of the K-wire and its insertion devices were mainly influenced by the change in operative goals and by the introduction of antibiotics. The first versions of the Kirschner wire were hammered through a predrilled hole into the bone, but later on drilling became the standard technique of insertion. Drilling is considered a simple way of implanting, with many advantages, such as percutaneous and atraumatic insertion. However, this technique also has its disadvantages like temperature elevation, resulting in osteonecrosis and heat-related complications. Despite these complications the K-wire is now standard for the treatment of hand fractures., worldwide
    corecore