    Clinical Comparison of a Novel Balloon-Expandable Versus a Self-Expanding Transcatheter Heart Valve for the Treatment of Patients with Severe Aortic Valve Stenosis: The EVAL Registry

    No full text
    Background: Transcatheter aortic valve replacement (TAVR) is an effective treatment option for patients with severe, symptomatic AS, regardless of the transcatheter heart valve (THV) implanted. Prior studies demonstrated a higher device success with lower paravalvular leak (PVL) using the balloon-expandable (BE) Sapien/XT THV vs. a self-expanding (SE) THV. However, few data are available on the performance of a novel BE THV. Purpose: to compare early clinical performance and safety of the newly available BE Myval THV (Myval, Meril Life Sciences Pvt. Ltd., India) vs. the commonly used SE (Evolut R, Medtronic) THV. Methods: A single-center, retrospective cohort analysis was performed with 166 consecutive patients undergoing TAVR from March 2019 to March 2021 for severe symptomatic AS treated with either the novel BE Myval or the SE Evolut R (ER) bioprosthesis. The primary endpoint was device success at day 30 according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included 30-day all-cause mortality, cardiovascular mortality, more than mild PVL, permanent pacemaker implantation (PPI) rates and a composite of all-cause mortality and disabling stroke at 6 months. Results: Among the 166 included patients, 108 patients received the SE ER THV and 58 patients were treated with the BE Myval THV. At baseline, the two groups showed comparable demographic characteristics. The primary composite endpoint of early device success occurred in 55 patients (94.8%) in the BE Myval group and in 90 patients (83.3%) in the SE ER group (OR 3.667, 95% CI 1.094–12.14; p = 0.048). At day 30, the BE Myval THV group exhibited a significantly lower incidence of more than mild PVL (BE Myval 3.45% vs. SE ER 14.8%, OR 0.2, 95% CI 0.05–0.8; p = 0.0338), along with a lower rate of PPI (BE Myval 11% vs. SE ER 24.2%, OR 0.38, 95% CI 0.15–0.99; p = 0.0535). At the 6-month follow-up, the incidence of all-cause mortality and disabling stroke did not significantly differ between the two groups, while the incidence of PPI (BE Myval 11% vs. SE ER 27.5%, OR 0.32, CI 95% 0.1273–0.8; p = 0.02) and ≥moderate PVL (BE Myval 6.9% vs. SE ER 19.8%, OR 0.31, 95% CI 0.1–0.94; p = 0.0396) was significantly lower in the BE Myval group. Conclusions: In patients with severe symptomatic AS undergoing TAVR, the novel Myval BE THV provided a comparable performance to the well-known ER SE THV, and it was associated with a lower rate of PPI and ≥moderate PVL within 30 days and 6 months after the procedure. Randomized, head-to-head comparison trials are needed to confirm our results

    Transcatheter aortic valve replacement with the self-expanding ACURATE Neo2 in patients with horizontal aorta: Insights from the ITAL-neo registry

    No full text
    Background: Horizontal aorta (HA), defined by an aortic angulation (AA) >= 48 degrees, is associated with worse outcomes particularly after self-expanding (SE) trans-catheter heart valve (THV) implantation. Although the SE ACURATE Neo THV demonstrated favorable procedural success rates in patients with HA, it remains associated with a non-negligible rate of moderate or greater paravalvular leak (PVL).Objectives: Aim of the study was to assess the performance of ACURATE Neo2 in the setting of HA.Methods: We performed a multicenter cohort analysis on patients with severe aortic valve stenosis and HA undergoing transcatheter aortic valve replacement (TAVR) with the Neo or Neo2 THV enrolled in the ITAL-neo registry. The primary endpoint was a composite of early safety and clinical efficacy at 30 days according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included the occurrence of moderate or severe PVL and 90-day clinical outcomes.Results: Among 900 patients included in the ITAL-neo registry, 407 exhibited HA; of these, 300 received a Neo THV and 107 a Neo2 THV. HA, irrespective of the THV implanted, emerged as an independent risk factor for developing >= moderate PVL. Technical and device success at 30-day follow-up was comparable between groups. However, Neo2 was associated with a significantly lower rate of >= moderate PVL vs. Neo: (5% vs. 15%; p = moderate PVL and AA in the Neo2 group, while PVL degree increased proportionally to the AA in the Neo cohort.Conclusion: In patients with HA, the new generation Acurate Neo2 THV was associated with a comparable device success rate and a significantly lower rate of >= moderate PVL, when compared with its predecessor
    corecore