8 research outputs found

    Analgesic Efficacy of Pfannenstiel Incision Infiltration with Ropivacaine 7.5 mg/mL for Caesarean Section

    Get PDF
    Background. Pain after Caesarean delivery is partly related to Pfannenstiel incision, which can be infiltrated with local anaesthetic solutions. Methods. A double- blind randomized control trial was designed to assess the analgesic efficacy of 7.5 mg/mL ropivacaine solution compared to control group, in two groups of one hundred and forty four parturients for each group, who underwent Caesarean section under spinal anaesthesia: group R (ropivacaine group) and group C (control group). All parturients also received spinal sufentanil (2.5 μg). Results. Ropivacaine infiltration in the Pfannenstiel incision for Caesarean delivery before wound closure leads to a reduction of 30% in the overall consumption of analgesics (348 550 mg for group R versus 504 426 mg for group C with P < .05), especially opioids in the first 24 hours, but also significantly increases the time interval until the first request for an analgesic (4 h 20 min ± 2 h 26 for group R versus 2 h 42 ± 1 h 30 for group C). The P values for the two groups were: P < .0001 for paracetamol, P < .0001 for ketoprofen and P for nalbuphine which was the most significant. There is no significant difference in the threshold of VAS in the two series. Conclusion. This technique can contribute towards a programme of early rehabilitation in sectioned mothers, with earlier discharge from the post-labour suite

    SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

    Get PDF
    Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The “standard” EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms (“neutral bremsstrahlung”, NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science

    Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

    Get PDF
    Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, 39Ar, a β emitter of cosmogenic origin. For large detectors, the atmospheric 39Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of 39Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of 39Ar with respect to AAr by a factor larger than 1400. Assessing the 39Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly γ-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector
    corecore