    Splitting the anterior mitral leaflet impairs left ventricular function in an ovine model

    Full text link
    OBJECTIVES: During mitral valve replacement, the anterior mitral leaflet is usually resected or modified. Anterior leaflet splitting seems the least disruptive modification. Reattachment of the modified leaflet to the annulus reduces the annulopapillary distance. The goal of this study was to quantify the acute effects on left ventricular function of splitting the anterior mitral leaflet and shortening the annulopapillary distance. METHODS: In 6 adult sheep, a wire was placed around the anterior leaflet and exteriorized through the left ventricular wall to enable splitting the leaflet in the beating heart. Releasable snares to reduce annulopapillary distance were likewise positioned and exteriorized. A mechanical mitral prosthesis was inserted to prevent mitral incompetence during external manipulations of the native valve. Instantaneous changes in left ventricular function were recorded before and after shortening the annulopapillary distance, then before and after splitting the anterior leaflet. RESULTS: After splitting the anterior leaflet, preload recruitable stroke work, stroke work, stroke volume, cardiac output, left ventricular end systolic pressure and mean pressure were significantly decreased by 26%, 23%, 12%, 9%, 15% and 11%, respectively. Shortening the annulopapillary distance was associated with significant decreases in the end systolic pressure volume relationship, preload recruitable stroke work, stroke work and left ventricular end systolic pressure by 67%, 33%, 15% and 13%, respectively. Shortening the annulopapillary distance after splitting the leaflet had no significant effect. CONCLUSIONS: Splitting the anterior mitral leaflet acutely impaired left ventricular contractility and haemodynamics in an ovine model. Shortening the annulopapillary distance after leaflet splitting did not further impair left ventricular function

    Contemporary outcomes of continuous-flow biventricular assist devices.

    Get PDF
    BACKGROUND: Significant right ventricular failure (RVF) complicating left ventricular assist device (LVAD) placement has been reported at 10–30%. Although primarily indicated for left ventricular failure, ventricular assist devices (VADs) have become utilized in a biventricular setup to combat right ventricular failure (RVF) following LVAD implantation. With the advent of continuous-flow LVADs (CF-LVADs) superseding their pulsatile predecessors, the shift towards CF-biventricular assist devices (CF-BiVADs) come with the prospect of improved outcomes over previous pulsatile BiVADs. We aim to review the literature and determine the outcomes of CF-BiVAD recipients. METHODS: A systematic review was performed to determine the outcomes of CF-BiVADs. Pre-operative demographics and device configuration data was collected. Primary outcomes evaluated were short-term survival, long-term survival, duration of support, and survival to transplant. Secondary outcomes evaluated included intensive care unit (ICU) and hospital length of stay (ICU-LOS and HLOS, respectively), pump thrombosis, pump exchange. Median and interquartile range was reported where appropriate. A major limitation was the likely overlap of cohorts across publications, which may have contributed to some selection bias. RESULTS: Of 1,282 screened, 12 publications were evaluated. Sample size ranged from 4 to 93 CF-BiVAD recipients, and follow-up ranged from 6 to 24 months. Mean age ranged from 34 to 52 years old. Forty-five percent of CF-BiVADs had right atrial (RA-) inflow cannulation, with the remaining being right ventricular (RV). Thirty-day survival was a median of 90% (IQR 82–97.8%) and 12-month survival was a median of 58.5% (IQR 47.5–62%). Where reported, rate of pump thrombosis (predominantly the right VAD) was a median of 31% (IQR 14–36%), although pump exchange was only 9% (IQR 1.5–12.5%). CONCLUSIONS: RVF post-LVAD implantation is a high morbidity and mortality complication. There is no on-label continuous-flow RVAD currently available. Thus, the modifications of LVADs for right ventricular support to combat pump thrombosis has resulted in various techniques. BiVAD recipients are predominantly transplant candidates, and complications of pump thrombosis and driveline infection whilst on wait-list are of great consequence. This study demonstrates the need for an on-label CF-BiVAD

    Analogue Mean Systemic Filling Pressure: a New Volume Management Approach During Percutaneous Left Ventricular Assist Device Therapy

    Full text link
    The absence of an accepted gold standard to estimate volume status is an obstacle for optimal management of left ventricular assist devices (LVADs). The applicability of the analogue mean systemic filling pressure (Pmsa) as a surrogate of the mean circulatory pressure to estimate volume status for patients with LVADs has not been investigated. Variability of flows generated by the Impella CP, a temporary LVAD, should have no physiological impact on fluid status. This translational interventional ovine study demonstrated that Pmsa did not change with variable circulatory flows induced by a continuous flow LVAD (the average dynamic increase in Pmsa of 0.20 ± 0.95 mmHg from zero to maximal Impella flow was not significant (p = 0.68)), confirming applicability of the human Pmsa equation for an ovine LVAD model. The study opens new directions for future translational and human investigations of fluid management using Pmsa for patients with temporary LVADs

    Large expert-curated database for benchmarking document similarity detection in biomedical literature search

    Get PDF
    Document recommendation systems for locating relevant literature have mostly relied on methods developed a decade ago. This is largely due to the lack of a large offline gold-standard benchmark of relevant documents that cover a variety of research fields such that newly developed literature search techniques can be compared, improved and translated into practice. To overcome this bottleneck, we have established the RElevant LIterature SearcH consortium consisting of more than 1500 scientists from 84 countries, who have collectively annotated the relevance of over 180 000 PubMed-listed articles with regard to their respective seed (input) article/s. The majority of annotations were contributed by highly experienced, original authors of the seed articles. The collected data cover 76% of all unique PubMed Medical Subject Headings descriptors. No systematic biases were observed across different experience levels, research fields or time spent on annotations. More importantly, annotations of the same document pairs contributed by different scientists were highly concordant. We further show that the three representative baseline methods used to generate recommended articles for evaluation (Okapi Best Matching 25, Term Frequency–Inverse Document Frequency and PubMed Related Articles) had similar overall performances. Additionally, we found that these methods each tend to produce distinct collections of recommended articles, suggesting that a hybrid method may be required to completely capture all relevant articles. The established database server located at https://relishdb.ict.griffith.edu.au is freely available for the downloading of annotation data and the blind testing of new methods. We expect that this benchmark will be useful for stimulating the development of new powerful techniques for title and title/abstract-based search engines for relevant articles in biomedical research

    Role of antioxidant enzymes and small molecular weight antioxidants in the pathogenesis of age-related macular degeneration (AMD)

    Get PDF

    Plant species diversity for sustainable management of crop pests and diseases in agroecosystems: a review

    Full text link

    Three-dimensional intracardiac echocardiography and pulmonary embolism

    Get PDF
    Background: Three-dimensional intracardiac echocardiography (3D ICE) with wide azimuthal elevation is a novel technique performed for assessment of cardiac anatomy and guidance of intracardiac procedures, being able to provide unique views with good spatial and temporal resolution. Complications arising from this invasive procedure and the value of 3D ICE in the detection and diagnosis of acute cardiovascular pathology are not comprehensively described. This case illustrates a previously unreported iatrogenic complication of clot displacement from the intra-vascular sheath upon insertion of a 3D ICE catheter and the value of 3D ICE in immediate diagnosis of clot in transit through the heart with pulmonary embolism. Case presentation: We conducted a translational study of 3D ICE with wide azimuthal elevation to guide implantation of a left ventricular assist device (Impella CP®) in eight adult sheep. A large-bore 14 Fr central venous sheath was used to enable right atrial and right ventricular access for the intracardiac catheter. Insertion of the 3D ICE catheter was accompanied by a sudden severe cardiorespiratory deterioration in one animal. 3D ICE revealed a large highly mobile mass within the right heart chambers, determined to be a clot-in-transit. The diagnosis of pulmonary clot embolism resulting from the retrograde blood entry into the large-bore sheath introducer, rapid clot formation and consequent displacement into venous circulation by the ICE catheter was made. The sheep survived this life-threatening event following institution of cardiovascular support allowing completion of the primary research protocol. Conclusion: This report serves as a serious warning to the researchers and clinicians utilizing long large-bore sheath introducers for 3D ICE and illustrates the value of 3D ICE in detecting clot-in-transit within right heart chambers

    Publisher Correction: Implantation of Impella CP left ventricular assist device under the guidance of three-dimensional intracardiac echocardiography (Scientific Reports, (2020), 10, 1, (17485), 10.1038/s41598-020-74220-8)

    Full text link
    This Article contained an error in the labelling of Supplementary Movie files. Supplementary Movies 11, 1, 2, 3, 4, 5, 6, 7, 8, 9 and 10 were incorrectly published as Supplementary Videos 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 and 11, respectively. This has now been corrected in the HTML; the PDF version of the paper was correct from the time of publication

    Rural and Remote Cardiology During the COVID-19 Pandemic: Cardiac Society of Australia and New Zealand (CSANZ) Consensus Statement.

    Full text link
    THE CHALLENGES:Rural and remote Australians and New Zealanders have a higher rate of adverse outcomes due to acute myocardial infarction, driven by many factors. The prevalence of cardiovascular disease (CVD) is also higher in regional and remote populations, and people with known CVD have increased morbidity and mortality from coronavirus disease 2019 (COVID-19). In addition, COVID-19 is associated with serious cardiac manifestations, potentially placing additional demand on limited regional services at a time of diminished visiting metropolitan support with restricted travel. Inter-hospital transfer is currently challenging as receiving centres enact pandemic protocols, creating potential delays, and cardiovascular resources are diverted to increasing intensive care unit (ICU) and emergency department (ED) capacity. Regional and rural centres have limited staff resources, placing cardiac services at risk in the event of staff infection or quarantine during the pandemic. MAIN RECOMMENDATIONS:Health districts, cardiologists and government agencies need to minimise impacts on the already vulnerable cardiovascular health of regional and remote Australians and New Zealanders throughout the COVID-19 pandemic. Changes in management should include