35 research outputs found
Left atrial anomalous muscular band as incidental finding during video-assisted mitral surgery
Congenital fibromuscular bands have been described inleft ventricle or right atrium and have been diagnosed by echocardiography and CT scan. The first report of anomalous band in the left atrium was described in 1897 by Rollestone (1). We hereby present a case of a patient with an incidental finding of left atrial band during a minimally invasive mitral surgery procedure
Spotlight on MicroPulse laser trabeculoplasty in open-angle glaucoma: What's on? A eeview of the literature
Glaucoma is the most common cause of permanent blindness in the world, caused by a progressive optic neuropathy. Patients with glaucoma are often treated with topical medicines therapy in order to reduce intra-ocular pressure (IOP). On the other hand, laser therapies, with the introduction of Argon Laser Trabeculoplasty (ALT) and successively with Selective Laser Trabeculoplasty (SLT), were reported to be effective in IOP control, with low adverse effect rates. In recent years, the micropulse laser, a subthreshold laser technology, was introduced with the goal of reducing side effects while maintaining the effectiveness of the laser treatments. Several studies focused on Micropulse Diode Laser Trabeculoplasty (MDLT) in open-angle glaucoma, to evaluate its effectiveness and possible side effects. Promising results were reported, but irradiation circumstances have not been standardized yet and its role as a substitute for previous laser techniques has yet to be defined. As a result, the goal of this review was to analyze the physical principles at the basis of MDLT and to frame it in the open-angle glaucoma management setting, highlighting the advantages and shortfalls of this technique
PreserFlo® MicroShunt: an overview of this minimally invasive device for open-angle glaucoma
For moderate-to-severe glaucoma, trabeculectomy remains the “gold standard” intraocular pressure (IOP)-lowering treatment; nonetheless, this method requires extensive post-operative maintenance. Microinvasive glaucoma surgery (MIGS) treatments are designed to lessen intra- and post-operative care burden while offering an acceptable IOP decrease for individuals with mild to moderate glaucoma. The PreserFlo® MicroShunt (previously InnFocus MicroShunt) is an 8.5 mm glaucoma drainage device manufactured from poly(styrene-block-isobutylene-block-styrene) (SIBS), an extremely biocompatible and bioinert material. The lumen is narrow enough to prevent hypotony, but big enough to avoid being obstructed by sloughed cells or pigment. The device is implanted ab externo, as a stand-alone procedure or in conjunction with cataract surgery, with intraoperative mitomycin C, and a bleb is produced under the conjunctiva and Tenon’s capsule. The MicroShunt was CE-marked in 2012 and designed for primary open-angle glaucoma, the IOP of which remains uncontrolled after maximally tolerated topical treatment. Several clinical trials evaluating the MicroShunt’s long-term safety and effectiveness have been conducted, highlighting the effectiveness of the device over time, along with a tolerable safety profile. The present review aims to gather evidence of PreserFlo’s effectiveness and safety results almost 10 years after its introduction, and furthermore, to compare it with other MIGS and with the gold-standard trabeculectomy for glaucoma management
Overview on defocus incorporated multiple segments lenses: a novel perspective in myopia progression management
Myopia is becoming more common across the world, affecting approximately two billion people and rising. Different kinds of therapies (optical, pharmaceutical, environmental, or behavioral) have been proposed to decrease myopia progression, but with variable results and a lack of standardization. The evidence that targeted myopic defocus inhibits eye length growth has paved the way for several contact and spectacle lense designs to induce a peripheral defocus, thus slowing myopia progression, but the perfect configuration has yet to be defined. One of the newest and more promising approaches in this field is the use of Defocus Incorporated Multiple Segments (DIMS) lenses. These lenses are built from the assumption that targeted myopic defocus, produced by 396 mid-peripheral lenslets with positive power, inhibits eye length growth. Recent studies have highlighted the effectiveness of these lenses compared to children who had worn single vision spectacle lenses, in terms of myopia control and tolerability. Despite the evidence that these lenses can help slow down the progression of myopia, the occasional mid-peripheral aberrations they can induce, as well as the overall eye strain that comes with wearing them, should not be overlooked. The aim of this review is to give attention to the advantages and the shortfalls of this new approach and to evaluate its effectiveness in clinical practice
Anterior Segment-Optical Coherence Tomography Bleb Morphology Comparison in Minimally Invasive Glaucoma Surgery: XEN Gel Stent vs. PreserFlo MicroShunt
Background: The purpose of this study is to compare the morphology of six-month follow-up blebs created by a subconjunctival glaucoma surgical device (XEN45) to those created by a PreserFlo MicroShunt with a sub-Tenon insertion, utilizing AS-OCT. Methods: A retrospective study of 29 eyes who underwent XEN45 implantation and 29 eyes who underwent PreserFlo MicroShunt implantation. The patients were analyzed at 24 h, 1 week, 1 month, 3 months and 6 months. At each visit, the maturation and morphological alterations of the blebs were observed, as well as connections with the IOP. Results: In both groups, IOP showed significant reduction at all follow ups (p < 0.0001). In XEN group, the most common bleb morphology in the immediate postoperative was the subconjuntival separation type (42%) followed by the uniform type (34%), with a trend inversion at 6 month follow up (51% of uniform type). On the contrary, the most common morphology after PreserFlo was the multiple internal layer (55%), which showed a tendency to reduce over time and was substituted by the microcystic multiform, whose percentage increased over time (17% at day 1 vs. 44% at month 6). Uniform appearance was associated by the posterior episcleral fluid (PEF) lake presence. Both horizontal and vertical diameters significantly increased over time. Conclusion: XEN and PreserFlo implantation resulted in the production of diffuse blebs with different characteristics, which may influence IOP lowering capacity and bleb revisions necessity over time
Convolutional neural network based on fluorescein angiography images for retinopathy of prematurity management
Purpose: The purpose of this study was to explore the use of fluorescein angiography (FA) images in a convolutional neural network (CNN) in the management of retinopathy of prematurity (ROP).Methods: The dataset involved a total of 835 FA images of 149 eyes (90 patients), where each eye was associated with a binary outcome (57 "untreated" eyes and 92 "treated"; 308 "untreated" images, 527 "treated"). The resolution of the images was 1600 and 1200 px in 20% of cases, whereas the remaining 80% had a resolution of 640 and 480 px. All the images were resized to 640 and 480 px before training and no other preprocessing was applied. A CNN with four convolutional layers was trained on 90% of the images (n = 752) randomly chosen. The accuracy of the prediction was assessed on the remaining 10% of images (n = 83). Keras version 2.2.0 for R with Tensorflow backend version 1.11.0 was used for the analysis.Results: The validation accuracy after 100 epochs was 0.88, whereas training accuracy was 0.97. The receiver operating characteristic (ROC) presented an area under the curve (AUC) of 0.91.Conclusions: Our study showed, we believe for the first time, the applicability of artificial intelligence (CNN) technology in the ROP management driven by FA. Further studies are needed to exploit different fields of applications of this technology.Translational Relevance: This algorithm is the basis for a system that could be applied to both ROP as well as experimental oxygen induced retinopathy
Femtosecond Laser-Assisted Cataract Surgery: Analysis of Surgical Phases and Comparison with Standard Phacoemulsification in Uncomplicated Cataracts
The aim of this work is to compare the time of surgical phases and the cumulative dissipated energy (CDE) of the phacoemulsification phase in femtosecond laser-assisted cataract surgery (FLACS) and in standard surgical procedures of phacoemulsification (PCS). This prospective, non-randomized study analyzed the data of 100 cataract surgeries, 66 using FLACS and 34 with standard PCS. The time of surgical phases was recorded by a digital chronometer; an additional parameter recorded was the CDE of the phacoemulsification phase. The mean time of femtosecond laser phase was 121.7 ± 27.3 s with minimal fluctuations in duration; the mean opening time of the corneal tunnel and the service incisions was 60.5 ± 20.4 s in the PCS, and 48.8 ± 17.4 s in FLACS (p = 0.04); the mean time of capsulorhexis was 39.6 ± 12.9 s in the PCS and 7.0 ± 5.2 s in FLACS (p < 0.0001); the mean time of phacoemulsification was 180.1 ± 45.6 s in the PCS and 163.0 ± 38.2 s in FLACS (p = 0.12); the mean aspiration time of the residual cortical was 66.3 ± 27.5 s in the PCS and 91.5 ± 35.7 s in FLACS (p = 0.02). Overall, the total surgical time of the cataract surgery was 742.3 ± 185.8 s in PCS and 985.1 ± 118.6 s in FLACS (p = 0.03). The mean CDE was 11.35 in the PCS and 8.3 in FLACS (p = 0.01). In conclusion, the greatest advantage obtained from the use of the femtosecond laser was the reduction of the duration of the phacoemulsification time and of the CDE parameter
Exploring AI-chatbots’ capability to suggest surgical planning in ophthalmology: ChatGPT versus Google Gemini analysis of retinal detachment cases
Background We aimed to define the capability of three different publicly available large language models, Chat Generative Pretrained Transformer (ChatGPT-3.5), ChatGPT-4 and Google Gemini in analysing retinal detachment cases and suggesting the best possible surgical planning.Methods Analysis of 54 retinal detachments records entered into ChatGPT and Gemini's interfaces. After asking 'Specify what kind of surgical planning you would suggest and the eventual intraocular tamponade.' and collecting the given answers, we assessed the level of agreement with the common opinion of three expert vitreoretinal surgeons. Moreover, ChatGPT and Gemini answers were graded 1-5 (from poor to excellent quality), according to the Global Quality Score (GQS).Results After excluding 4 controversial cases, 50 cases were included. Overall, ChatGPT-3.5, ChatGPT-4 and Google Gemini surgical choices agreed with those of vitreoretinal surgeons in 40/50 (80%), 42/50 (84%) and 35/50 (70%) of cases. Google Gemini was not able to respond in five cases. Contingency analysis showed significant differences between ChatGPT-4 and Gemini (p=0.03). ChatGPT's GQS were 3.9 +/- 0.8 and 4.2 +/- 0.7 for versions 3.5 and 4, while Gemini scored 3.5 +/- 1.1. There was no statistical difference between the two ChatGPTs (p=0.22), while both outperformed Gemini scores (p=0.03 and p=0.002, respectively). The main source of error was endotamponade choice (14% for ChatGPT-3.5 and 4, and 12% for Google Gemini). Only ChatGPT-4 was able to suggest a combined phacovitrectomy approach.Conclusion In conclusion, Google Gemini and ChatGPT evaluated vitreoretinal patients' records in a coherent manner, showing a good level of agreement with expert surgeons. According to the GQS, ChatGPT's recommendations were much more accurate and precise