21 research outputs found

    Evidence for the different physiological significance of the 6- and 2-minute walk tests in multiple sclerosis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Researchers have recently advocated for the 2-minute walk (2MW) as an alternative for the 6-minute walk (6MW) to assess long distance ambulation in persons with multiple sclerosis (MS). This recommendation has not been based on physiological considerations such as the rate of oxygen consumption (V·O<sub>2</sub>) over the 6MW range.</p> <p>Objective</p> <p>This study examined the pattern of change in V·O<sub>2 </sub>over the range of the 6MW in a large sample of persons with MS who varied as a function of disability status.</p> <p>Method</p> <p>Ninety-five persons with clinically-definite MS underwent a neurological examination for generating an Expanded Disability Status Scale (EDSS) score, and then completion of the 6MW protocol while wearing a portable metabolic unit and an accelerometer.</p> <p>Results</p> <p>There was a time main effect on V·O<sub>2 </sub>during the 6MW (<it>p </it>= .0001) such that V·O<sub>2 </sub>increased significantly every 30 seconds over the first 3 minutes of the 6MW, and then remained stable over the second 3 minutes of the 6MW. This occurred despite no change in cadence across the 6MW (<it>p </it>= .84).</p> <p>Conclusions</p> <p>The pattern of change in V·O<sub>2 </sub>indicates that there are different metabolic systems providing energy for ambulation during the 6MW in MS subjects and steady state aerobic metabolism is reached during the last 3 minutes of the 6MW. By extension, the first 3 minutes would represent a test of mixed aerobic and anaerobic work, whereas the second 3 minutes would represent a test of aerobic work during walking.</p

    Mobility, Balance and Falls in Persons with Multiple Sclerosis

    Get PDF
    BACKGROUND: There is a lack of information concerning the relation between objective measures of gait and balance and fall history in persons with MS (PwMS). This investigation assessed the relation between demographic, clinical, mobility and balance metrics and falls history in persons with multiple sclerosis (MS). METHODS: 52 ambulatory persons with MS (PwMS) participated in the investigation. All persons provided demographic information including fall history over the last 12 months. Disease status was assessed with Expanded Disability Status Scale (EDSS). Walking speed, coordination, endurance and postural control were quantified with a multidimensional mobility battery. RESULTS: Over 51% of the participants fell in the previous year with 79% of these people being suffering recurrent falls. Overall, fallers were older, had a greater prevalence of assistive devices use, worse disability, decreased walking endurance, and greater postural sway velocity with eyes closed compared to non-fallers. Additionally, fallers had greater impairment in cerebellar, sensory, pyramidal, and bladder/bowel subscales of the EDSS. CONCLUSIONS: The current observations suggest that PwMS who are older, more disabled, utilize an assistive device, have decreased walking coordination and endurance and have diminished balance have fallen in the previous year. This suggests that individuals who meet these criteria need to be carefully monitored for future falls. Future research is needed to determine a prospective model of falls specific to PwMS. Additionally, the utility of interventions aimed at reducing falls and fall risk in PwMS needs to be established

    Accuracy of StepWatch™ and ActiGraph accelerometers for measuring steps taken among persons with multiple sclerosis

    Get PDF
    Introduction There has been increased interest in the objective monitoring of free-living walking behavior using accelerometers in clinical research involving persons with multiple sclerosis (MS). The current investigation examined and compared the accuracy of the StepWatch activity monitor and ActiGraph model GT3X+ accelerometer for capturing steps taken during various speeds of prolonged, over-ground ambulation in persons with MS who had mild, moderate, and severe disability. Methods Sixty-three persons with MS underwent a neurological examination for generation of an EDSS score and undertook two trials of walking on the GAITRite electronic walkway. Participants were fitted with accelerometers, and undertook three modified six-minute walk (6MW) tests that were interspersed with 10–15 minutes of rest. The first 6MW was undertaken at a comfortable walking speed (CWS), and the two remaining 6MW tests were undertaken above (faster walking speed; FWS) or below (slower walking speed; SWS) the participant's CWS. The actual number of steps taken was counted through direct observation using hand-tally counters. Results The StepWatch activity monitor (99.8%–99.9%) and ActiGraph model GT3X+ accelerometer (95.6%–97.4%) both demonstrated highly accurate measurement of steps taken under CWS and FWS conditions. The StepWatch had better accuracy (99.0%) than the ActiGraph (95.5%) in the overall sample under the SWS condition, and this was particularly apparent in those with severe disability (StepWatch: 95.7%; ActiGraph: 87.3%). The inaccuracy in measurement for the ActiGraph was associated with alterations of gait (e.g., slower gait velocity, shorter step length, wider base of support). Conclusions This research will help inform the choice of accelerometer to be adopted in clinical trials of MS wherein the monitoring of free-living walking behavior is of particular value
    corecore